• 제목/요약/키워드: vibrator

검색결과 296건 처리시간 0.023초

박형 초음파모터의 최적 설계 (Optimal Design of Thin Type Ultrasonic Motor)

  • 정성수;전호익;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.335-340
    • /
    • 2008
  • In this study, novel structured thin ultrasonic rotary motor has been proposed. Ultrasonic motors are based on an elliptical motion on the surface of elastic body. Thin brass plate was used as a cross shaped vibrator and eight ceramic plates were attached on upper side and bottom side of the brass plate. From the thin stator, elliptical displacements of the four contact tips were obtained. To find the optimal size of the stator, motions of the motors were simulated using ATILA by changing length, width and thickness of the ceramics. The stators had commonly three resonance peaks and contact tips of the stator moved on tangential or normal trajectories at these resonance peaks. The maximum displacements at the resonance peaks were compared. As results, maximum displacements of the contact tips were obtained at the length of 16 mm, width of 6 mm and thickness of 0.4 mm. Changes of the resonance frequencies were inversely proportional to the length of ceramic and proportional to the width of ceramic. The motor was fabricated by using the designed stator. And, the characteristics of the motor were compared with the simulated results. When the motor was fabricated with these results, speed fo 935 rpm was obtained by input voltage of 25 Vrms at 93.5 kHz.

압전 횡효과를 이용한 무지향성 주파수가변 초음파트랜스듀서 (Frequency Controllable Wide-Beam Ultrasonic Transducer with Transverse Mode)

  • 김정순;김무준;하강렬;강갑중
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.417-423
    • /
    • 2004
  • In order to obtain wide-beam characteristics and variable resonant frequency of a ultrasonic transducer for the array source, an electrode of transverse mode piezoelectric vibrator is divided, and an electronic inductance is connected to the divided electrodes. The electronic inductance is made by GIC (General Impedance Converter) circuit. Because the GIC circuit is made of OP-Amps and other passive elements, the value of the inductance can be selected easily. As the results, the electronic inductance is variable in the range from 0.2 mH to 1.2 mH. Using the inductance, the resonance frequency of the transducer can be changed in the range from 73 kHz to 86 kHz. In the directivity of the transducer, it is confirmed that the beam width of the transducer is wider than $80^{\circ}$ at -3 dB in water.

EYE-type 압전 발전소자의 설계 및 출력특성 (Design and Power Output Characteristics of an EYE-type Piezoelectric Energy Harvester)

  • 정성수;이병하;강신출;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제29권2호
    • /
    • pp.84-89
    • /
    • 2016
  • We present the results of a study of a piezoelectric generator that generates electricity by the application of tension to an element. A device is named "EYE-type generator". The EYE-type generator consists of a rectangular ceramic and two elastic body plates that are attached to upper and lower surfaces of a ceramic. If tension is applied to both ends of the elastic body, that tension is transformed to pressure on the ceramic through a change in the form of the elastic body, causing a piezoelectric effect whereby electricity is generated by the ceramic. This generator is relatively durable because a forces are not applied directly to the ceramic. We examined dependencies of the generator's output characteristics on the size of the ceramic and elastic body. A resonance and output characteristics were analyzed by using a finite element method. The generator was fabricated based on results of the analysis, and this was attached to a frequency-controllable vibrator to measure the output characteristics. The measured results were compared with results of the simulation, and the results pointed to the practicality of the design.

Use of Wet Chemical Method to Prepare β Tri-Calcium Phosphates having Macro- and Nano-crystallites for Artificial Bone

  • Chang, Myung Chul
    • 한국세라믹학회지
    • /
    • 제53권6호
    • /
    • pp.670-675
    • /
    • 2016
  • Calcium phosphate crystallites were prepared by wet chemical method for use in artificial bone. In order to obtain ${\beta}$-tricalcium phosphate (TCP), nano-crystalline calcium phosphate (CaP) was precipitated at $37^{\circ}C$ and at $pH5.0{\pm}0.1$ under stirring using highly active $Ca(OH)_2$ in DI water and an aqueous solution of $H_3PO_4$. The precipitated nano-crystalline CaP solution was kept at $90^{\circ}C$ for the growth of CaP crystallites. Through the growing process of CaP crystallites, we were able to obtain various sizes of rectangular CaP crystallites according to the crystal growing times. Dry nano-crystalline CaP powders at $37^{\circ}C$ were mixed with dry macro-crystalline CaP crystallites and the shaped mixture sample was fired at $1150^{\circ}C$ to make a ${\beta}-TCP$ block. Several tens of nm powders were uniformly coated on the surface, which was comprised of powders of several tens of ${\mu}m$, using a vibrator. The mixing ratio between the nanometer powders and the micrometer powders greatly affected the mechanical strength of the mixture block; the most appropriate ratio of these two materials was 50 wt% to 50 wt%. The sintered block showed improved mechanical strength, which was caused by the solid state interaction between the nano-crystalline ${\beta}-TCP$ and the macro-crystalline ${\beta}-TCP$.

박형 초음파 모터의 구동특성 (Driving Characteristic of Thin-type Ultrasonic Motor)

  • 정성수;전호익;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.343-343
    • /
    • 2008
  • Newly designed structure of a thin ultrasonic rotary motor was proposed. Thin brass plate was used as a cross shaped vibrator and eight ceramic plates were attached on the upper and bottom sides of the brass plate as in Figure 1. The thin type ultrasonic motor has the structure adherent piezoelectric ceramic on the top and bottom surface of the thin elastic body. The direction of polarization is decided so as to occur the elliptical displacement in regular sequence at touch point A, B, C and D of stator contacted with rotor. By applying two electric fields which have 90 degree phase difference on the ceramics, each contact points make rotational displacements as in figure 2. Finite element analysis program ATILA was used to find the optimal size of the stator. As a result of the simulation, elliptical displacements of the tips were obtained at off-resonance frequencies. The maximum displacements of the contact tips were obtained at the length of 16[mm], width of 6[mm] and thickness of 0.4[mm]. Changes of the resonance frequencies were inversely proportional to the length of ceramic and proportional to the width of ceramic. Elliptical motions of the contact tips. of the stator were consistently obtained at off resonance frequencies. From a prototype motor, speed of 600[rpm] was obtained at 20[Vrms].

  • PDF

압전식 에너지 수확기의 주파수 특성 (Frequency Characteristics of Energy Harvester Using Piezoelectric Elements)

  • 윤소남;김동건;함영복;박중호;정병홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3131-3135
    • /
    • 2008
  • This paper presents an energy harvester using piezoelectric elements that is a kind of generator which converts the mechanical power to the electric one using windmill system with many PZT actuators. In this study, low frequency characteristics of the cantilever-type piezoelectric actuator are experimentally investigated. Advantages of the cantilever use are to take a very large displacement and to improve the endurance of the PZT element. The material of cantilever is an aluminum and three kinds of cantilever of which size is $150[mm]{\times}20[mm]{\times}1.5[mm]$, $170[mm]{\times}20[mm]{\times}1.5[mm]$ and $190[mm]{\times}20[mm]{\times}1.5[mm]$ were experimented, respectively. The cantilever was fixed on the vibrator. The characteristics of frequency and mass variation of cantilever end part such as 0[g], 5[g], 10[g] are investigated. Maximum voltage was outputted at the condition of $150[mm]{\times}20[mm]{\times}1.5[mm]$ and 10[g] of mass. It was confirmed that the lower natural frequency at the larger length of cantilever and at the bigger of mass is gotten.

  • PDF

초음파 분무 열분해법에 의한 ZnO 합성의 이론과 실제 (Theory and practice of synthesized ZnO powders by ultrasonic spray pyrolysis method)

  • 서수형;신건철
    • 한국결정성장학회지
    • /
    • 제5권1호
    • /
    • pp.60-66
    • /
    • 1995
  • 초음파 분무기에 의해 분무된 질산아연 염($Zn(NO_3)_2$) 용액(0.5M)의 에어로졸 거동과 분포에 대한 실제 실험 결과는 computer simulation 결과와 일치하였다. 즉, 반응관(thermophoresis)에 의해 반응관 중심부로 이동하였다. 또한 에어로졸의 농도 분포는 축길이가 증가함에 따라 반응관 중심쪽에 높았다. 합성된 ZnO 입자 중에서 반응과 중심에서는 볼 수 없었던 깨진 형태의 shell-like aggregates가 반응관 벽근처에서 관찰되었으며, 입자의 크기는 반응관 벽쪽($ 1.2 {\mu\textrm{m}$)이 중심쪽($0.9 {\mu\textrm{m}$)보다 컸다.

  • PDF

뱀장어, Anguilla japonica의 산소소비, 암모니아 배설 및 혈액성상에 미치는 진동의 영향 (Effect of Vibration Stress on the Oxygen Consumption, Ammonia Excretion and Blood Characteristics of the Cultured Eel, Anguilla japonica)

  • 이정열;허준욱
    • 한국양식학회지
    • /
    • 제17권4호
    • /
    • pp.262-267
    • /
    • 2004
  • Physiological responses (oxygen consumption, ammonia excretion, hemoglobin, red blood cell and white blood cell) of cultured eel, Anguilla japonica to vibration stress were studied in an indoor experimental system. Vibration of 76-93 dB (V) from an electric vibrator was provided in 15-minute intervals during daytime (0800-1800) over a ten day period. Oxygen consumption before the beginning of the experiment (0 day) was 83.9 mg $O_2$$.$kg$^{-1}$ ㆍhr$^{-1}$ . After 1, 5 and 10 days of stress respiration rate decreased by 37.5, 53.7 and 70.5%, respectively. Ammonia excretion showed a similar pattern to that of oxygen consumption. Ammonia excretion decreased by 80.1 % following 10 days of vibration stress. Blood hemoglobin concentration also decreased at 1, 3 and 10th day were 29.4% on day 1,83.9% on day 3 and 87.9% by day 10, while red blood cell counts at day 1 and day 10th were 59.8% and 84.7% lower than initial counts, respectively. The white blood cell count increased by 191.2% at day 7, dropping to 41.5% at day 10. Physiological activity was reduced by 50% following 3.4 days of vibration stress.

선박의 수직방향 진동 감쇠를 위한 진동보상기의 개발 (Development of Vibration Compensator for Vertical Vibration Damping of Ships)

  • 정민제;김태옥;안중환;김화영
    • 센서학회지
    • /
    • 제29권3호
    • /
    • pp.205-210
    • /
    • 2020
  • The aim of this study is to develop a vertical vibration compensator that attenuates the vertical vibration of ships. The vibration compensator was designed according to the principle of generating vertical excitation forces by rotating two eccentric bodies of the same mass in opposite directions at the same rotational speed. In addition, the structural stability was analyzed using the finite element method. The maximum stress in the drive shaft was 95.6 MPa, which was approximately 35% of the allowable stress of the shaft material (SM45C, 270 MPa). The acceleration signals of the vibrator compensator body and the testbed were determined to evaluate the efficiency of the vibration compensator and the designed excitation forces. Subsequently, the excitation forces were estimated based on the relationship between force and acceleration. The estimated results were very close to the theoretical values with an error of less than 3%.

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.