• Title/Summary/Keyword: vibration-based methods

검색결과 610건 처리시간 0.042초

집중질량을 갖는 회전중심방향 자유단 외팔보의 진동해석 (Vibration Analysis of Rotating Inward Cantilever Beams With a Tip-Mass)

  • 이건호;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.389-391
    • /
    • 2014
  • The Vibration Analysis of Rotating Inward Beams Considering The Tip-Mass is presented based on Euler-Bernoulli beam theory. The frequency equations, which are coupled through gyroscopic coupling terms, are calculated using hybrid deformation variable modeling along with the Rayleigh-Ritz assumed mode methods. In this study, resulting system of ordinary differential equations shows the effects of angular speed, and Young's modulus ratio. It is believed that the results will be a reference with which other researchers and commercial FE analysis program, ANSYS can compare their results.

  • PDF

OKPO 300 진동 특성에 대한 실험적 연구 (Experimental Study of Vibration Characteristics of OKPO 300)

  • 황아롬
    • 한국해양공학회지
    • /
    • 제30권5호
    • /
    • pp.400-404
    • /
    • 2016
  • This paper presents experimental results for the vibration characteristics of the small unmanned underwater vehicle (UUV) OPKO 300, which was designed and manufactured by Daewoo ship and Marine Engineering Ltd. The autonomy of UUVs has led to an increase in their use in scientific, military, and commercial areas because their autonomy makes it possible for UUVs to be utilized instead of humans in hazardous missions such as mine countermeasure missions (MCM). Since it is impossible to use devices based on electromagnetic waves to gather information in an underwater environment, only sonar systems, which use sound waves, can be used in underwater environments, and their performance can strongly affect the autonomy of a UUV. Since a thruster system, which combines a motor and propeller in a single structure, is widely used as the propulsion system of a UUV and is mounted on the outside of a UUV’s stern, it can generate vibration, which can be transferred throughout the shell of the UUV from its stern to its bow. The transferred vibration can affect the performance of various sonar systems such as side-scan sonar or forward-looking sonar. Therefore, it is necessary to estimate the effect of the transferred vibration of the UUV on the sonar systems. Even if various numerical methods were used to analyze the vibration problem of a UUV, it would be hard to predict the vibration phenomena of a UUV at the initial design stage. In this work, an experimental study using OKPO 300 and an impact hammer was carried out to analyze the vibration feature of a small real UUV in the air. The frequency response function of the vibration based on the experimental results is presented.

소리 선호도 조사에 사용하는 청음평가법의 비교 연구 (A Comparative Study on Methods of Jury Test used for Sound Preferences)

  • 조현호;성원찬;김성현;박동철;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.165-170
    • /
    • 2014
  • Quantifying the perception of human is of great interest for the optimal characterization of the interaction of persons with their environment. The direct approach to such measurements is based on jury-test methods. In this study we considered which jury-test method is more efficient and exact way to measure the preferences for operating sound of car. Moreover we needed to research selection criteria of jury-test methods in accordance with the properties of sound samples. We choose two sample sounds; door locks which generate simple impact sounds and window lifts which are consisted of long and complex sound. For each sound sample we conducted two jury-test methods respectively and discussed about the results.

  • PDF

진동 분석을 이용한 사출성형기 유압펌프 결함 진단 시스템에 관한 연구 (A Study on Failure Diagnosis System for a Hydraulic Pump in Injection Molding Machinery Using Vibration Analysis)

  • 김태현;전용호;이문구
    • 한국생산제조학회지
    • /
    • 제22권3호
    • /
    • pp.343-348
    • /
    • 2013
  • In line with the advances in factory automation, various pieces of equipment are now operated in batch processes controlled by computers. However, many kinds of faults can occur in complicated and large systems, which can result in low productivity and economic loss. The reliability and safety of systems have been studied because of the difficulty of determining the severity and location of faults. Therefore, it is necessary to detect and diagnose such faults in order to guarantee the reliability and safety of the equipment. In this paper, a diagnosis method for the ball bearings of a hydraulic pump is applied using a vibration signal for the maintenance of injection molding equipment. The bearings' defects are selected as a main failure mode through a failure mode and effect analysis (FMEA). Usually, there are nonlinear and impulse components of vibration in a ball bearing with faults. For the effective fault diagnosis of a ball bearing, nonlinear diagnostic methods and time-frequency analysis are applied, in addition to the methods currently used, such as power spectrum, time series analysis, and statistical methods. As a result of this study, a failure diagnosis system is provided that is useful even for non-experts. This is a condition-based method that makes it possible to resolve problems in a timely and economical way, in contrast to the prior method, which required regular but wasteful maintenance based on the experience of expensive external experts.

Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses

  • Nguyen, Tuan-Cuong;Huynh, Thanh-Canh;Yi, Jin-Hak;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • 제24권4호
    • /
    • pp.385-403
    • /
    • 2017
  • In recent years, the wind energy has played an increasingly important role in national energy sector of many countries. To harvest more electric power, the wind turbine (WT) tower structure becomes physically larger, which may cause more risks during long-term operation. Associated with the great development of WT projects, the number of accidents related to large-scaled WT has also been increased. Therefore, a structural health monitoring (SHM) system for WT structures is needed to ensure their safety and serviceability during operational time. The objective of this study is to develop a hybrid damage detection method for WT tower structures by measuring vibration and impedance responses. To achieve the objective, the following approaches are implemented. Firstly, a hybrid damage detection scheme which combines vibration-based and impedance-based methods is proposed as a sequential process in three stages. Secondly, a series of vibration and impedance tests are conducted on a lab-scaled model of the WT structure in which a set of bolt-loosening cases is simulated for the segmental joints. Finally, the feasibility of the proposed hybrid damage detection method is experimentally evaluated via its performance during the damage detection process in the tested model.

선박용 엔진 MR 마운트의 최적설계: 최대 댐핑력 (Optimal Design of Magnetorheological Mount for Ship Engines : Maximum Damping Force)

  • 박준희;도쑤웬푸;구오흥;강옥현;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.273-278
    • /
    • 2013
  • This paper presents optimal design procedures of mount based on a magnetorheological (MR) fluid to isolate the vibration in heavy diesel engine system. At first, frequency response and force-displacement transmissibility methods are used to get required damping force that is necessary for effective vibration isolation. From this result, a new type of high damping force engine mount is proposed and the governing equation of Bingham plastic behavior of MR fluid in flow path is mathematically derived under cylindrical coordinates. Finally, parametric design optimization featuring finite element is performed using ANSYS software to get the required damping force in MR mount system which can be used to reduce engine vibration. Damping force of the MR mount is then determined as an objective function in this analysis based on ANSYS. Furthermore, Magnetic analysis is then applied in this process.

  • PDF

선박용 엔진 MR 마운트의 최적설계: 최대 댐핑력 (Optimal Design of Magnetorheological Mount for Ship Engines : Maximum Damping Force)

  • 박준희;도쑤웬푸;구오흥;강옥현;최승복
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.472-478
    • /
    • 2013
  • This paper presents optimal design procedures of mount based on a magnetorheological(MR) fluid to isolate the vibration in heavy diesel engine system. At first, frequency response and force-displacement transmissibility methods are used to get required damping force that is necessary for effective vibration isolation. From this result, a new type of high damping force engine mount is proposed and the governing equation of Bingham plastic behavior of MR fluid in flow path is mathematically derived under cylindrical coordinates. Finally, parametric design optimization featuring finite element is performed using ANSYS software to get the required damping force in MR mount system which can be used to reduce engine vibration. Damping force of the MR mount is then determined as an objective function in this analysis based on ANSYS. Furthermore, Magnetic analysis is then applied in this process.

진동 신호 이용 모델 기반 모터 결함 검출 시스템 개발 (Development of a Model-Based Motor Fault Detection System Using Vibration Signal)

  • 임호순;;정길도
    • 제어로봇시스템학회논문지
    • /
    • 제9권11호
    • /
    • pp.874-882
    • /
    • 2003
  • The condition assessment of engineering systems has increased in importance because the manpower needed to operate and supervise various plants has been reduced. Especially, induction motors are at the core of most engineering processes, and there is an indispensable need to monitor their health and performance. So detection and diagnosis of motor faults is a base to improve efficiency of the industrial plant. In this paper, a model-based fault detection system is developed for induction motors, using steady state vibration signals. Early various fault detection systems using vibration signals are a trivial method and those methods are prone to have missed fault or false alarms. The suggested motor fault detection system was developed using a model-based reference value. The stationary signal had been extracted from the non-stationary signal using a data segmentation method. The signal processing method applied in this research is FFT. A reference model with spectra signal is developed and then the residuals of the vibration signal are generated. The ratio of RMS values of vibration residuals is proposed as a fault indicator for detecting faults. The developed fault detection system is tested on 800 hp motor and it is shown to be effective for detecting faults in the air-gap eccentricities and broken rotor bars. The suggested system is shown to be effective for reducing missed faults and false alarms. Moreover, the suggested system has advantages in the automation of fault detection algorithms in a random signal system, and the reference model is not complicated.

소음원간 누화 효과에 대한 수학적 모델 및 전달 경로 분석법 비교를 통한 검증 (The Mathematical Model on Crosstalk Effect of Airborne Noise Sources and Verification based on Comparison between Transfer Path Analysis Methods)

  • 변재환;김윤재;강연준;강구태;권오준;홍진철
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.943-951
    • /
    • 2008
  • In this paper, the mathematical model on crosstalk effect between acoustic noise sources is presented. Based on this model, a theoretical value to quantitate crosstalk effect of sources can be defined on the authority of reverberation property of surrounding which sources are located, relative magnitudes of sources and phase deference between acoustic wave transferred from all of sources. In order to verify crosstalk effect factor, experiments are made for two cases, weak and strong crosstalk effect condition, by using toro representative transfer path analysis(TPA) methods.

Sound Power Measurements Based on ISO 3741 and 3745

  • Lee, Kang-Il;Kim, Hyun-Tae;Yoon, Suk-Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • 제19권1E호
    • /
    • pp.13-21
    • /
    • 2000
  • In this paper, we present the description and results of experimental study of the sound power measurements based on International Standards ISO 3741 and 3745. The sound power emitted by a calibrated reference sound source was measured in a reverberation room and a free field over a reflecting plane, using the precision methods of International Standards ISO 3741 direct method and ISO 3745, respectively. The sound power measurements carried out in this study give accurate estimation and also show that both methods for determining the sound power levels of a sound source in a reverberation room and a free field over a reflecting plane, according to the ISO 3741 and 3745, respectively, have proved equally good.

  • PDF