• Title/Summary/Keyword: vibration sensor

Search Result 1,195, Processing Time 0.031 seconds

Characteristics of Torque and Vibration-Noise take into account Permanent Magnet Overhang of BLDC Motor for Robots (로봇 구동용 BLDC Motor의 영구자석 오버행에 따른 토크 및 진동.소음 특성)

  • Kang, Gyu-Hong;Kim, Duck-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.346-352
    • /
    • 2006
  • In Brushless DC Motor, there are Permanent Magnets (PMs) with driving circuit and sensor for detecting to rotor position and rotation speed. In the case of using hall IC sensor which response to magnetic flux, that is required to additional sensor magnet for rotor position detecting. Most of BLDC motor, However, take asymmetrical overhang of PM in rotor instead of additional sensor magnet for operating of hall IC sensor. The asymmetrical overhang of PM occur rotor thrust to z-axis direction that is lead to not only damage of bearing but also intensive noise and vibration. Therefore, the analysis of magnet overhang effect in the side of vibration and drive to hall If sensor is required to precise. In this paper, 2-D Finite Element Method is used to solve precise field computation and thrust of z-axis direction considering asymmetrical magnet overhang. And also the z-axis thrust from the analysis result is compared to experimental result. In conclusion, the purpose of this paper minimize to noise and vibration of BLDC Motor as analyzes to asymmetrical magnet overhang effect.

Response Characteristics of Acoustic Emission Sensor according to Partial Discharge Quantities (부분방전 전하량에 따른 음향방출 센서의 응답특성)

  • Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.383-387
    • /
    • 2010
  • The response characteristics of AE (acoustic emission) sensors with a coupled vibration mode and a non-coupled vibration mode were investigated according to PD(partial discharge) quantities in XLPE (cross linked polyethylene) sheets and craft papers immersed in insulating oil. The response voltages of a coupled vibration mode AE sensor were linearly proportional to the PD quantities up to 1,000 pC in XLPE sheets, while a non-coupled vibration mode AE sensor did not show the similar linearity. In case of a test of craft papers immersed in insulating oil, a linearity between response voltages and PD quantities was observed up to 550 pC, but after that, similar linearity between response voltage of any types of AE sensor and PD quantities was not shown.

A new magnetic sensor for the non-contact measurement of bending vibrations of non-ferromagnetic pipes (비자성 배관의 비접촉 굽힘 진동 측정을 위한 자기 센서의 개발)

  • Han, Soon-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1154-1158
    • /
    • 2006
  • This investigation suggests a new non-contact type sensor that can measure flexural vibrations of a non-ferromagnetic pipe. The sensor works on the reversed Lorentz force mechanism; however, anti-symmetric bias magnetic field suggested in this work should be applied to measure bending vibration of a non-ferromagnetic pipe. The importance of the suggested magnetic field is verified by a series of experiments. The sensor is applied to the bending vibration measurement and modal testing of an aluminum pipe and shows satisfactory working performance compared to others.

  • PDF

Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors (광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

Papers : Simultaneous Measurement of Strain , Temperature , and Vibration Using Fiber Optic Sensor (논문 : 광섬유 센서를 이용한 변형률, 온도, 진동의 동시 측정)

  • Gang,Hyeon-Gyu;Bang,Hyeong-Jun;Hong,Chang-Seon;Kim,Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.44-48
    • /
    • 2002
  • In this paper, we demonstrated the simultaneous measurment of triple parameters such as strain, temperature, and vibration using single FBG/EFPI hybrid sensor. The FBG/EFPI sensor system for the strain and temperature measurement and the EFPI sensor system for the the vibration measurement were combined by a wavelength division multiplexer. The optical source of FBG/ EFPI sensor system is a wavelength-swept fiber laser(WSFL) and that of an EFPI sensor system is a laser diode. We performed the simultaneous measurement of thermal strain, temperature, and vibration of a aluminum beam placed in a thermal chamber and validated the efficiency of the constructed measurment system.

A Walking Vibration Sensing System using a Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 보행 진동 측정 시스템에 관한 연구)

  • Kim, Jaeki;Yeom, Sanghun;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • In this paper, a walking vibration sensing system (WVS system) using a Fiber Bragg Grating sensor (FBG sensor) is proposed. The seismic part of the FBG sensor was redesigned for sensitivity enhancement. The external excitation was assumed to be the walking cycle of an adult male. The FBG seismic sensor was redesigned using CATIA and ABAQUS such that the sensor's first mode natural frequency is 3.5 Hz (which is a value near the external excitation frequency). Compared with existing walking vibration sensing systems, this newly created system improves sensitivity 15 times. It is also suitable for intrusion detection applications.

Vibration Control System Design of Composite Shell by Profile Optimization of PVDF film (PVDF 필름 형상최적화에 의한 복합재료 쉘의 진동제어 시스템 설계)

  • 황준석;목지원;김승조
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.228-231
    • /
    • 2000
  • The active vibration control of laminated composite shell has been performed with the optimized sensor/actuator system. PVDF film is used fur the material of sensor/actuator. Finite element method is utilized to model the whole structure including the piezoelectric sensor/actuator system, The distributed selective modal sensor/actuator system is established to prevent the adverse effect of spillover. In the finite element discretization process, the nine-node shell element with five nodal degrees of freedoms is used. Electrode patterns and lamination angles of sensor/actuator are optimized using genetic algorithm. Sensor is designed to minimize the observation spillover, and actuator is designed to minimize the system energy of the control modes under a given initial condition. Modal sensor/actuator profiles are optimized for the first and the second modes suppression of singly curved cantilevered composite shell structure. Discrete LQG method is used as a control law. The real time vibration control with profile optimized sensor/actuator system has been performed. Experimental result shows successful performance of the integrated structure for the active vibration control.

  • PDF

Development of the Inductive Proximity Sensor Module for Detection of Non-contact Vibration (비접촉 진동 검출을 위한 유도성 근접센서모듈 개발)

  • Nam, Si-Byung;Yun, Gun-Jin;Lim, Su-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.61-71
    • /
    • 2011
  • To measure the fatigue of metallic objects at high speed vibration while non-contact precision displacement measurement on how to have a lot of research conducted. Noncontact high-speed vibration detection sensor of the eddy current sensors and laser sensors are used, but it is very expensive. Recently, High-speed vibrations detection using an inexpensive inductive sensor to have been studied, but is still a beginner. In this paper, a new design of an inexpensive inductive proximity sensor has been suggested in order to measure high frequency dynamic displacements of metallic specimens in a noncontact manner. Detection of the existing inductive sensors, detection, integral, and amplified through a process to detect the displacement noise due to weak nature of analog circuits and integral factor in the process of displacement detection is slow. The proposed method could be less affected by noise, the analog receive and high-speed signal processing is a new way, because AD converter (Analog to Digital converter) without using the vibration frequency signals directly into digital signals are converted. In order to evaluate the sensing performance, The proposed sensor module using non-contact vibration signals were detected while shaker vibration frequencies from 30Hz to 1,100 Hz at intervals of vibrating metallic specimens. Experimental results, Vibration frequency detection range of the metallic specimins within close proximity to contactless 5mm could be measured from DC to 1,100Hz and vibration amplitude of the resolution was $20{\mu}m$. Therefore, the proposed non-contact inductive sensor module for precision vibration detection sensor is estimated to have sufficient performance.

A Study on the Tool Vibration Measurement Using the Fiber Optic Interferometric Sensor in Lathe Cutting Process (광섬유 간섭계 센서를 이용한 선삭가공 공구진동 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.32 no.2
    • /
    • pp.171-187
    • /
    • 2007
  • The purpose of this study is to measure the lathe tool vibration and verify its usefulness using the fiber optic interferometeric sensor instead of using common accelerometer. To compare two vibration signals a Fabry-Perot fiber optic sensor(FOS) is directly attached to the left-side surface of the lathe tool and an accelerometer is attached near to the fiber optic sensor. Measurement signals from the FOS and theoretical results of receptance simulation are compared. When the amplitude of tool vibration increased the frequency shift phenomena was occurred. This means that mass effect occurred and vibration spectrum moved to the low frequency region. Generally this results is agreement to the regenerative chatter. The chatter frequency is not same as the natural frequency of the tool itself. The FOS can also applied to laboratory experiments for students. This experimental technique is perhaps the first attempts because of directly attachment technique. Therefore, suggested Fabry-Perot fiber optic sensor can be used to monitoring the tool wear and vibration.

An experimental analysis of vibration-induced noise isolation characteristics of a sonar acoustic sensor (소나 음향센서의 진동유기 소음 차단 특성에 대한 실험적 연구)

  • Kim, Kyungseop;Je, Yub;Kim, Ho-Jun;Cho, Yo-Han;Lee, Jeong-Min;Kim, Donghyeon;Chang, Woosuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • In this paper, the results of underwater vibration experiment are analyzed to verify platform vibration-induced noise isolation characteristics of a hull-mounted acoustic sensor. The experimental condition causing platform vibration-induced noise is generated using the mock-up hull, where the acoustic sensor is installed, with shaker in an acoustic water tank. The performance indices of ATF (Acceleration Transfer Function), AVS (Acceleration Voltage Sensitivity), and IL (Insertion Loss) for the acoustic sensor are calculated from the output of the standard accelerometers, which are installed on the mock-up hull and the acoustic sensor, and the output signal of the acoustic sensor. The frequency-dependent noise isolation characteristics of the acoustic sensor are analyzed based on the calculated performance indices and an effectiveness of the experiment is examined.