• Title/Summary/Keyword: vibration and instability

Search Result 366, Processing Time 0.025 seconds

A study of acoustic coupled instability at the propulsion test facility for KSR-III rocket (KSR-III Rocket 종합 시험 설비에서 발생한 열-음향 불안정 현상에 관한 연구)

  • Cho, Sang-Yeon;Kang, Sun-Il;Han, Sang-Yeop;Cho, In-Hyun;Oh, Seung-Hyub;Lee, Dae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.636-640
    • /
    • 2002
  • Acoustic coupled combustion instability, which is one of the most undesirable phenomena in the development of liquid propellant rocket engine, can cause serious damage to a rocket itself, and must be avoided by all means. Unfortunately, KSR-III rocket went through combustion instability during engine start at the propulsion test article No.2. To resolve the problem, time sequence (cyclogram) has been changed, and baffle system has been applied. In consequence of change, stable combustion was achieved.

  • PDF

Analysis of Fluid-elastic Instability In the CE-type Steam Generator Tube (CE형 증기발생기 전열관에 대한 유체탄성 불안정성 해석)

  • 박치용;유기완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.261-271
    • /
    • 2002
  • The fluid-elastic instability analysis of the U-tube bundle inside the steam generator is very important not only for detailed design stage of the SG but also for the change of operating condition of the nuclear powerplant. However the calculation procedure for the fluid-elastic instability was so complicated that the consolidated computer program has not been developed until now. In this study, the numerical calculation procedure and the computer program to obtain the stability ratio were developed. The thermal-hydraulic data in the region of secondary side of steam generator was obtained from executing the ATHOS3 code. The distribution of the fluid density can be calculated by using the void fraction, enthalpy, and operating pressure. The effective mass distribution along the U-tube was required to calculate natural frequency and dynamic mode shape using the ANSYS ver. 5.6 code. Finally, stability ratios for selected tubes of the CE type steam generator were computed. We considered the YGN 3.4 nuclear powerplant as the model plant, and stability ratios were investigated at the flow exit region of the U-tube. From our results, stability ratios at the central and the outside region of the tube bundle are much higher than those of other region.

Effects of Whole Body Vibration Exercise on Lower Extremity Muscle Activity and Balance Ability in Football Player with Chronic Ankle Instability

  • Jeong, Yong-Sik;Kim, Je-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.6
    • /
    • pp.293-298
    • /
    • 2017
  • Purpose: The purpose of this study was to determine the effects of whole body vibration exercise (WBVE) on lower extremity muscle activity and balance ability according to different methods of exercises in football player and use it as basic data for the rehabilitation training of chronic ankle instability. Methods: Thirty subjects were randomly divided into two groups: the two groups, which each group have 15 members, are WBVE group and neuromuscular training (NMT) group according to training method. The exercise program was conducted for six weeks. Subjects were measured on lower extremity muscle activity and balance ability. Results: The muscle activity increasement of the WBVE group was significantly higher than that of the NMT group (p<0.05) and the balance ability decreasement of the WBVE group was significantly higher than that of the NMT group (p<0.05). Conclusion: These findings of this study suggest that WBVE may have a beneficial effect on improvement of lower extremity muscle activity and balance ability in football player with chronic ankle instability.

A Study on the Hydraulic Stability of Fuel Rod for the Advanced $16{\times}16$ Fuel Assembly Design ($16{\times}16$ 개량핵연료 연료봉의 수력적 안정성에 관한 연구)

  • Jeon Sang-Youn
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.4 s.70
    • /
    • pp.347-360
    • /
    • 2005
  • The fuel rod instability can be occurred because of the axial and cross flow due to the flow anomaly and/or flow redistribution in the lower core plate region of the pressurized water reactor. The fuel rod vibration due to the hydraulic instability is one of the root causes of fuel failure. The verification on the fuel rod vibration and instability is needed for the new fuel assembly design to verify the fuel rod instability. In this study, the fuel rod vibration and stability analyses were performed to investigate the effect of the grid height, fuel rod support condition, and span adjustment on the fuel rod vibration characteristics for the advanced $16{\times}16$ fuel assembly design. Based on the analysis results, the grid height and grid axial elevation of the advanced $16{\times}16$ fuel assembly design were proposed.

Vibration Characteristics of Heat Exchanger Tube Bundles in Two-Phase Cross-Flow (2상 횡유동을 받는 열교환기 관군의 진동특성)

  • 김범식;박태철
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.199-208
    • /
    • 1994
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as nuclear steam generators, condensers and reboilers. An understanding of damping and of flow-induced vibration excitation mechanisms in necessary to avoid problems due to excessive tube vibration. In this paper, we present the results of experiments on normal-triangular tube bundles of pitch to tube diameter ratio, p/d, 1.22, 1.32 and 1.47. The bundle were subjected to air-water mixtures to simulate realistic mass fluxes and vapour qualities corresponding to void fractions from 5 to 99%. Damping, fluidelastic instability and turbulence- induced excitation are discussed. The behaivior of damping and two vibration mechanisms are different for intermittent flows from for bubbly flows. The effect of pitch to tube diameter ratio and void fraction is dominant on damping and fluidelastic instability.

  • PDF

A Study on the Nonlinear Motion of a Vertical Liquid Jet (수직하방 분사된 주의 비선형 거동에 관한 연구)

  • Seok, Ji-Gwon;Jeong, Hwan-Mun;Mun, Su-Yeon;Lee, Chung-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.45-54
    • /
    • 2002
  • The breakup phenomena of a vertical laminar jet issuing from capillary tubes in a quiescent ambient air are investigated using a forced vibration analysis of the surface wave. Using a linear approach to the transient jet velocity, an approximate solution fur the longitudinal motion of a vertical liquid jet is theoretically derived, thus performing an instability analysis by a vibration method. The damping term of this equation is nonlinear as it depends on dimensionless parameters, a Weber number, and an Ohnesorge number. The instability condition is determined based on whether the coefficient of the damping term is less than zero or not. Uniform drop formation is dependent on the vibration frequency fur the forced vibration case.

A Study on the Flow=Induced Vibration of Tube Array in Uniform Crossflow(II) On the Flow-Induced Vibration of Two Interfering Circular Cylinders in Tandem (균일 유동장내 튜브배열의 유동관련 진동에 관한 연구( II ) 직렬로 배열된 두 원주의 유동여기 진동에 관하여)

  • 이기백;김봉환;양장식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1518-1528
    • /
    • 1993
  • The wake-induced vibration and proximity-induced vibration of two interfering circular cylinders in tandem are investigated experimentally, using an elastically supported cylinder and a fixed cylinder in uniform crossflow. Dynamic responses and flow periodicity in wake are measured to investigate the effect of system parameters on aerodynamic instability. The parameters include the free stream wind velocity and the position of two interfering circular cylinders. The oscillating behavior of the amplitude of the elastically supported cylinder is changed by varying the position, the relative gap spacing between two interfering circular cylinders and the reduced velocities. In small gap spacing between the elastically supported cylinder located to upstream and the circular cylinder fixed to downstream, the fluidelastic instability is founded. The vibration amplitude decreases notably as gap spacing between two interfering circular cylinders becomes large. The dynamic behavior at g/D-4.0 is similar to that of the single circular cylinder.

Viscous fluid induced vibration and instability of FG-CNT-reinforced cylindrical shells integrated with piezoelectric layers

  • Bidgoli, Mahmood Rabani;Karimi, Mohammad Saeed;Arani, Ali Ghorbanpour
    • Steel and Composite Structures
    • /
    • v.19 no.3
    • /
    • pp.713-733
    • /
    • 2015
  • In this paper, viscous fluid induced nonlinear free vibration and instability analysis of a functionally graded carbon nanotube-reinforced composite (CNTRC) cylindrical shell integrated with two uniformly distributed piezoelectric layers on the top and bottom surfaces of the cylindrical shell are presented. Single-walled carbon nanotubes (SWCNTs) are selected as reinforcement and effective material properties of FG-CNTRC cylindrical shell are assumed to be graded through the thickness direction and are estimated through the rule of mixture. The elastic foundation is modeled by temperature-dependent orthotropic Pasternak medium. Considering coupling of mechanical and electrical fields, Mindlin shell theory and Hamilton's principle, the motion equations are derived. Nonlinear frequency and critical fluid velocity of sandwich structure are calculated based on differential quadrature method (DQM). The effects of different parameters such as distribution type of SWCNTs, volume fractions of SWCNTs, elastic medium and temperature gradient are discussed on the vibration and instability behavior of the sandwich structure. Results indicate that considering elastic foundation increases frequency and critical fluid velocity of system.

Nonlinear higher order Reddy theory for temperature-dependent vibration and instability of embedded functionally graded pipes conveying fluid-nanoparticle mixture

  • Raminnea, M.;Biglari, H.;Tahami, F. Vakili
    • Structural Engineering and Mechanics
    • /
    • v.59 no.1
    • /
    • pp.153-186
    • /
    • 2016
  • This paper addresses temperature-dependent nonlinear vibration and instability of embedded functionally graded (FG) pipes conveying viscous fluid-nanoparticle mixture. The surrounding elastic medium is modeled by temperature-dependent orthotropic Pasternak medium. Reddy third-order shear deformation theory (RSDT) of cylindrical shells are developed using the strain-displacement relations of Donnell theory. The well known Navier-Stokes equation is used for obtaining the applied force of fluid to pipe. Based on energy method and Hamilton's principal, the governing equations are derived. Generalized differential quadrature method (GDQM) is applied for obtaining the frequency and critical fluid velocity of system. The effects of different parameters such as mode numbers, nonlinearity, fluid velocity, volume percent of nanoparticle in fluid, gradient index, elastic medium, boundary condition and temperature gradient are discussed. Numerical results indicate that with increasing the stiffness of elastic medium and decreasing volume percent of nanoparticle in fluid, the frequency and critical fluid velocity increase. The presented results indicate that the material in-homogeneity has a significant influence on the vibration and instability behaviors of the FG pipes and should therefore be considered in its optimum design. In addition, fluid velocity leads to divergence and flutter instabilities.

Characteristics of Flow-induced Vibration for KSNP Steam Generator Tube at Concentrated Tube Plugging Zone (한국표준원전 증기발생기의 관막음 집중 영역 근방에서의 유체유발진동 특성해석)

  • 유기완;조봉호;박치용;박수기
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.452-459
    • /
    • 2003
  • The characteristics of fluid-elastic instability and effects of turbulent excitations for the KSNP steam generator tubes were investigated numerically. The information for the thermal-hydraulic data of the steam generator has been obtained by using the ATHOS3-MOD1 code and the flow-induced vibration(FIV) analysis has been conducted by using the PIAT(program for Integrity assessment of SG tube) code. The KSNP steam generator has the concentrated plugging zone at the vicinity of the stay cylinder inside the SG. To investigate the cause of the concentrated tube plugging zone, the FIV analysis has been performed for various column and row number of the steam generator tubes. From the results of FIV analysis the stability ratio due to the fluid-elastic instability and vibrational amplitude due to the turbulent excitation in the concentrated plugged zone have a trend of larger values than those of the outer concentrated tube Plugging zone.