• Title/Summary/Keyword: vertical water flow

Search Result 540, Processing Time 0.026 seconds

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

A Review of Constructed Wetlands for Water Quality Management in India

  • Farheen, Shaista;Geronimo, Franz Kevin;Guerra, Heidi;Reyes, Nash Jett;Choi, Hyseon;Jeon, Minsu;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.129-129
    • /
    • 2021
  • Constructed wetlands (CW) are artificially developed wetlands that are used to control water pollution. In central India, the field application of CW started on the late 1990s but are mostly focused on wastewater treatment. In this paper, different existing and experimental studies on constructed wetlands were reviewed to be able to determine the current status of wetlands in India to identify the type of CW that is more suitable in managing a specific target pollutant and type of wastewater. Wetlands were categorized into three types: vertical flow, horizontal flow, and hybrid while the wastewater were classified as domestic and industrial. Based on the review, 80% of constructed wetlands are used for treating domestic wastewater while 20% are treating industrial wastewater. Inflow analysis showed that industrial wastewater in hybrid constructed wetland produced the highest average concentration for parameters like COD (2851 mg/L) and BOD (5715 mg/L) while the lowest concentration was TN (13.97 mg/L) found in municipal wastewater. In terms of removing nonpoint source pollutants, it was revealed that vertical flow constructed wetlands (VFCW) are more effective at removing TSS and BOD as compared to horizontal flow constructed wetlands (HFCW) and hybrid constructed wetlands (HCW). HCW were found to be capable of efficiently removing COD and TN. Meanwhile, HFCW showed the highest TP removal among all the types of wetlands. In addition, VFCW were more effective for domestic wastewater while HCW are more effective for treating industrial wastewater. Lastly, there is currently a need to conduct further research on constructed wetlands for industrial wastewater as well as stormwater treatment to be able to gather more data and improve wetland design, performance, and maintenance.

  • PDF

Effects of Flow Diretion and Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Two-Phase Flow(I) - In Case of Upward Flow - (수직이상유에서 유동방향과 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (I))

  • 손병진;김인석;김문철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.856-866
    • /
    • 1987
  • In the present paper a statistical method using probability density function has been applied to investigate experimentally the flow patterns and fluctuations of time-averaged local void fraction in air-water two-phase mixtures which flow vertically upwards in concentric annuli. This study was carried out using three vertical concentric annuli. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel inner rod. The rod diameter is either 12mm, 16mm or 20mm. The two-phase flow patterns observed in the experiment were bubbly, slug, annular and each transition patterns. It was first demonstrated that the variance, coefficients of skewness and kurtosis calculated from probability density function on time-averaged local void fraction can be used to identify the flow patterns in the annular passage, and the fluctuation of time-averaged local void fraction varies with the radial position in annular gap and the flow pattern.

Optimization study of pulsating jet for reducing the separation bubble behind the vertical fence (수직벽 후방박리영역 감소를 위한 맥동제트의 최적화 연구)

  • Choi, Young-Ho;Kang, In-Su;Kim, Hyoung-Bum
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.185-188
    • /
    • 2008
  • In this study, we experimentally investigated that the optimization of pulsating jet to reduce the separated flow region behind the vertical fence. The vertical fence was submerged in the turbulent boundary layer in the circulating water channel and we applied phase averaged PIV method to measure the instantaneous velocity fields around the fence. One cycle of pulsating jet is divided into 20 phases and grabbed total 200 instantaneous velocity fields at each phase. The experiments were performed by varying the frequency, maximum jet velocity and the shape of pulsating jet wave. Pulsating jet was precisely made by piston-type pump controlled by the computer. The obtained results were compared with normal fence flow. From this study, we found there is the specific frequency which is effective in reducing the reattachment region.

  • PDF

Hydrographic Model Test on Prevention against Vortex Occurrence for Vertical Bulb Turbine

  • Yamato, Shoichi;Nakamura, Shogo;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.418-425
    • /
    • 2009
  • A vertical bulb turbine unit with elbow type draft tube has been developed due to avoidance of complicated assembling and long standstill period at overhaul in comparison with conventional horizontal bulb turbine unit. Before designing the prototype vertical bulb unit, a hydrographic model test was carried out to establish the ideal design concept for this innovative generating unit. Froude similarity is not available for vortex occurrence. Consequently, an intake structure without air entraining vortices under all the flow conditions is developed, and it is confirmed that the surge wave at load rejection is not affected harmful influence for other constructions.

Experimental Study of Manipulating the Vertical Fence Wake using the Vortex Generator (와류 생성기를 이용한 수직벽 후류 제어의 실험적 연구)

  • Lee, Sang-Hyuk;Kang, In-Su;Cha, Jae-Eun;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.12-16
    • /
    • 2010
  • The effect of vortex generators to manipulate the separated flow region behind the vertical fence was experimentally investigated. The experiments were performed in the circulating water channel. The parameters used in this study were the distance between the fence and vortex generators and size of vortex generators. Digital PIV method was applied to measure the instantaneous velocity fields around the fence. And the obtained flow properties were compared with those of fence How without the vortex generators. The obtained results quantitatively shows the specific size and distance of vortex generators which were effective to reduce the mean reattachment length of separation bubble behind the fence.

POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1285-1292
    • /
    • 2009
  • The effects of the narrowed upside gap on nucleate pool boiling heat transfer in a vertical annulus were investigated experimentally. For the study, a stainless steel tube with a diameter of 25.4 mm and saturated water that kept an atmospheric condition were used. The ratio between the gaps measured at the upper and the lower regions of the annulus ranged from 0.18 to 1. Two different lengths of the modified gap also were investigated. The change in heat transfer due to the modified gap became evident as the gap ratio decreased and the length of the gap increased. As the gap ratio became less than 0.51, a significant decrease in heat transfer was observed compared to the plain annulus. The longer gap size resulted in an additional decrease in heat transfer. The major cause for the tendency was attributed to the formation of lumped bubbles around the upper region of the annulus followed by the increased flow friction between the fluid and the surface around the modified gap.

ANALYSIS OF VELOCITY STRUCTURE OF WALL JET ORIGINATING FROM CIRCULAR ORIFICES IN SHALLOW WATER

  • Kim, Dae-Geun;Seo, Il-Won
    • Water Engineering Research
    • /
    • v.3 no.4
    • /
    • pp.235-245
    • /
    • 2002
  • In this study, breakwater model which has several outlet pipes to discharge water is settled in the experimental open channel and mean velocity distributions of multi wall jet are measured. The length of flow of flow establishment of wall jet is shorter than that of free jet and decay rate of jet centerline longitudinal velocity along x is linear in 0.3 $\leq$ x/$\l_q$ $\leq$ 17. The rate of vertical width and lateral width spreading of multi wall jet is respectively 0.0753, 0.157~0.190.

  • PDF

Visualization of Gas/liquid Ejector Flow and Void Fraction Measurement using Fiber Optic Probe (기체-액체 이젝터 유동의 가시화와 광섬유 탐침에 의한 기포분율 측정)

  • Choi, Sung Hwan;Ji, Ho Seong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • Gas/liquid two-phase ejector is a device without moving parts, in which liquid is used to drive gas of a low-pressure source. In this paper, the hydrodynamic characteristics of a vertical down type two-phase ejector were studied using an air-water loop system. Entrained air flow rates were measured with inlet and outlet pressures of the ejector with varying water flow rate. Homogeneous bubbly flows in the discharge pipe were confirmed by the high speed flow visualization method. Quantitative measurements of void fraction were made using a newly developed fiber optic probe system.

Water carrying iron (iii) oxide (Fe3O4) ferrofluid flow and heat transfer due to deceleration of a rotating plate

  • Bhandari, Anupam
    • Structural Engineering and Mechanics
    • /
    • v.82 no.5
    • /
    • pp.679-690
    • /
    • 2022
  • This research effort examines the flow behavior and heat transfer assessment of water carrying iron (iii) oxide magnetic fluid due to a rotating and moving plane lamina under the influence of magnetic dipole. The effect of rotational viscosity and magnetic body force is taken into consideration in the present study. The involvement of the moving disk makes a significant contribution to the velocity distribution and heat transfer in rotational flow. Vertical movement of the disk keeps the flow unsteady and the similarity transformation converts the governing equation of unsteady flow into nonlinear coupled differential equations. The non-dimensional equation in the present system is solved through the finite element procedure. Optimizing the use of physical parameters described in this flow, such results can be useful in the rotating machinery industries for heat transfer enhancement.