• 제목/요약/키워드: vertical water flow

검색결과 538건 처리시간 0.178초

Preparation, Characterization of activated carbon fiber (ACF) from loofah and its application in composite vertical flow constructed wetlands for Tetracycline removal from water

  • Ahmed, Sanjrani Manzoor;Zhou, Boxun;Wang, Yue;Yang, Hang;Zheng, You P.;ShiBin, Xia
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.313-321
    • /
    • 2020
  • ACF preparation from different materials and its application in constructed wetlands for wastewater treatment has been focused in environmental field. Different materials have been used to prepare ACF around the world. This study aims to prepare, characterize and use of ACF from loofah for removal of Tetracycline from water through composite vertical flow constructed wetlands. ACF was prepared and it was tested for characterization, later it was used for removal of Tetracycline from water through composite vertical flow constructed wetlands. In composite vertical flow constructed wetlands, three HRTs were set according to the experiment, 1D, 2D, and 3D is individually. Samples were transported immediately from collection point to laboratory for analyzing. Samples were measured for Tetracycline (TC), Total Phosphorus (TP), and Total nitrogen and COD. Tetracycline absorbance with respective 356nm was obtained good and HRT is important factor. Results show that composite vertical flow constructed wetlands with ACF from luffa is best option and it is recommended to study further deep analysis.

수직원통관에서 선회유동의 속도분포에 관한 연구 (A Study on Swirling Flow in a Vertical Circular Tube)

  • 장태현;오건제;이해수;김상윤;도덕희
    • 한국가시화정보학회지
    • /
    • 제9권3호
    • /
    • pp.16-23
    • /
    • 2011
  • Experiment and numerical investigation are performed on swirling water flow in a vertical circular tube. This kind of flow is used in heat exchangers, combustion chambers, thermal power plants, and other mechanical equipment to move slurries or to convey materials. However, limited information on swirling flow in vertical circular tubes is available. In the current paper, the three-dimensional particle image velocimetry(PIV) technique is employed to compare the measured velocity profiles of water along the vertical circular tube with those of non-swirl flow. In addition, computational fluid dynamics(CFD) code was applied to calculation of the flow velocities with swirl.

개수로 측벽 세로돌출줄눈의 흐름저항 (Flow Resistance of Vertical Rib Sidewall in Open Channel)

  • 박상덕;지민규;남아름;우태영;신승숙
    • 한국수자원학회논문집
    • /
    • 제46권9호
    • /
    • pp.947-956
    • /
    • 2013
  • 급경사 산지하천 수충부의 호안은 대부분 콘크리트 옹벽으로 되어있다. 표면이 매끄러운 콘크리트 옹벽호안은 유속을 더 강화시키기 때문에 수충부 홍수피해의 원인이 되기도 한다. 본 연구에서는 개수로의 한 측벽에 설치한 정사각형 단면의 세로돌출줄눈이 흐름저항에 미치는 영향을 파악하기 위해 수리실험을 수행하였다. 돌출줄눈의 설치간격은 무차원 돌출줄눈 간격 ${\lambda}_{nv}$를 기준으로 조도유형 d형과 k형을 포함하도록 설계하였다. 흐름의 Froude 수는0.81~1.12의 범위였다. 흐름저항은 돌출줄눈의 설치간격과 유량에 좌우되었다. ${\lambda}_{nv}$가 9일 때 흐름저항이 가장 큰 것으로 나타났다. 세로돌출줄눈은 유량이 증가하면 d형 조도에서는 흐름저항을 감소시켰으나 k형 조도에서는 흐름저항을 증가시켰다. 흐름저항의 증가폭은 ${\lambda}_{nv}$이 9~12의 범위에서 상대적으로 더 크게 나타났다. 세로돌출줄눈에 의한 흐름저항은 대부분 형상저항에 의한 것이며 그 등가조도높이는 수심규모로 발생할 수 있고 흐름저항에 미치는 영향이 매우 크다. 측벽의 세로돌출줄눈은 흐름저항을 증가시키고 최대유속의 발생위치를 수로의 횡단면 중앙방향으로 이동시키는 수단으로 사용될 수 있을 것이다.

Flow regime transition criteria for vertical downward two-phase flow in rectangular channel

  • Chalgeri, Vikrant Siddharudh;Jeong, Ji Hwan
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.546-553
    • /
    • 2022
  • Narrow rectangular channels are employed in nuclear research reactors that use plate-type nuclear fuels, high heat-flux compact heat exchangers, and high-performance micro-electronics cooling systems. Two-phase flow in narrow rectangular channels is important, and it needs to be better understood because it is considerably different than that in round tubes. In this study, mechanistic models were developed for the flow regime transition criteria for various flow regimes in co-current air-water two-phase flow for vertical downward flow inside a narrow rectangular channel. The newly developed criteria were compared to a flow regime map of downward air-water two-phase flow inside a narrow rectangular channel with a 2.35-mm gap width under ambient temperature and pressure conditions. Overall, the proposed model showed good agreement with the experimental data.

Density-surfactant-motivated removal of DNAPL trapped in dead-end fractures

  • 여인욱;이강근;지성훈
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.51-54
    • /
    • 2003
  • Three kinds of experiments were conducted to test existing methods and develop an effective methodology for the remediation of DNAPL trapped in vertical dead-end fractures. A water-flushing method failed to remove TCE from vertical dead-end fractures where no fluid flow occurs. A water-flushing experiment implies that existing remediation methods, utilizing water-based remedial fluid such as surfactant-enhanced method, have difficulty in removing DNAPL trapped from the vertical downward dead-end fractures, because of no water flow through dead-end fractures, capillary, and gravity forces. Fluid denser than TCE was injected into the fracture network, but did not displace TCE from the vertical dead-end fractures. Base(B on the analysis of the experiments, the increase in the density of the dense fluid and the addition of surfactant to the dense fluid were suggested, and this composite dense fluid with surfactant effectively removed TCE from the vertical dead-end fractures.

  • PDF

Physical Model Investigation of a Compact Waste Water Pumping Station

  • Kirst, Kilian;Hellmann, D.H.;Kothe, Bernd;Springer, Peer
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.285-291
    • /
    • 2010
  • To provide required flow rates of cooling or circulating water properly, approach flow conditions of vertical pump systems should be in compliance with state of the art acceptance criteria. The direct inflow should be vortex free, with low pre-rotation and symmetric velocity distribution. Physical model investigations are common practice and the best tool of prediction to evaluate, to optimize and to document flow conditions inside intake structures for vertical pumping systems. Optimization steps should be accomplished with respect to installation costs and complexity on site. The report shows evaluation of various approach flow conditions inside a compact waste water pumping station. The focus is on the occurrence of free surface vortices and the evaluation of air entrainment for various water level and flow rates. The presentation of the results includes the description of the investigated intake structure, occurring flow problems and final recommendations.

낙동강 중⋅하류에서 표층 시료와 수직 예망 시료의 동물플랑크톤 군집 구조 차이 비교 (Differences in Zooplankton Community Structure between Surface Water and Vertical Integrated Water in Middle and Down Stream of Nakdong River)

  • 김민석;박혜경
    • 한국물환경학회지
    • /
    • 제39권3호
    • /
    • pp.215-222
    • /
    • 2023
  • Zooplankton are primary consumers in the food web connecting primary producers and predators such as small fish, playing an important role in energy transfer in aquatic ecosystems. Therefore, it is essential to understand the zooplankton community structure in material cycle and energy flow in aquatic ecosystems. Zooplankton in large rivers with a low flow rate would distribute vertically as in lakes. In this study, we collected zooplankton by surface water filtration and vertical haul method with 64 ㎛-mesh plankton net at three stations (ND-1, ND-2, ND-3) in Nakdong River fortnightly from June 2018 to December 2019. Species composition and individual densities were analyzed. All three stations showed differences in relative abundance of zooplankton groups between surface water and vertical integrated water, with the largest difference shown in the deepest station, ND-2. In vertically integrated water at ND-2, the relative abundance of rotifera was low by a maximum of 25% and that of cladocera was high by a maximum of 22% compared to surface water samples. These results indicate that surface water filtration method is not enough to represent the community structure of zooplankton compared to the vertical haul method in large rivers.

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Study on visualization of water mixing flows in a digester equipped with a vertical impeller by using radiotracers

  • Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen;Lim, Jae Cheong
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.170-177
    • /
    • 2020
  • A mixer with a new concept design has been adapted into water treatment plants. It reportedly cuts down the energy consumption of the mixer by the new mixer, which moves vertically and creates internal flows toward its bottom. However, no experimental observations have been made on the internal flow caused by a vertical impeller. In this study, a radiotracer experiment, radioactive particle tracking (RPT) technique, and particle image velocimetry (PIV) were carried out to visualize the flow in the mixer, and compared to each other. The results show that the flow patterns from these techniques are very similar to each other, and the performance of the mixer was good enough to mix the inner materials.