• Title/Summary/Keyword: vertical valve

Search Result 50, Processing Time 0.026 seconds

Force Control of 6-DOF Pneumatic Joystick

  • Tanaka, Yoshito;Hitaka, Yasunobu;Yun, So-Nam;Kim, Ji-U;Jeong, Eun-A;Park, Jung-Ho;Ham, Young-Bog
    • Journal of Power System Engineering
    • /
    • v.19 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • In this paper, it is presented the development of a new type force feedback system. It is based on a 6-DOF Stewart parallel mechanism which has six pneumatic actuated cylinders. The thrust force of each cylinder is controlled by PWM control for the solenoid valve and it is actualized by PIC controller. When the pneumatic actuator is controlled, it must be considered the influence on the compressibility of air. For this problem, we guarantee the control characteristics by the effect of the accumulator. It is confirmed that the thrust force of the cylinder can be applied to the pneumatic parallel mechanism, and is presented the experimental result of force control for vertical direction.

Aorticopulmonary Window: one case report (대동맥중격결손증[수술치험 1예])

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.302-306
    • /
    • 1981
  • Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.

  • PDF

Echocardiographic Assessment of Papillary Muscle Size and Function in Normal Beagle Dogs

  • Kim, Mijin;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.155-158
    • /
    • 2019
  • Morphologic changes or functional impairments of the papillary muscle (PM) can influence mitral valve competence. The purpose of this study was to investigate PM size and contractile function using two-dimensional and color tissue Doppler echocardiography in normal dogs. 35 unsedated Beagle dogs without cardiovascular disease were examined. The vertical (VD) and horizontal diameter (HD) of the posterior and anterior PM was measured at end-diastole, and compared with the thickness of the left ventricular posterior wall (LVPWd). Longitudinal systolic movement of the PM was quantified as myocardial velocity and strain using tissue Doppler. The VD, HD, and ratios (VD/LVPWd, HD/LVPWd, VD/HD) were significantly greater in the posterior than anterior PM (P < 0.001). The VD and HD of posterior PM and the HD of anterior PM were significantly correlated with LVPWd (r = 0.47, 0.44, and 0.42, respectively). Body weight was significantly correlated with VD of posterior PM (r = 0.37). The peak systolic tissue velocity of the PM was $4.93{\pm}1.25cm/sec$ and peak strain was $-30.83{\pm}11.92%$. PM size and systolic function can be quantitatively assessed using two-dimensional and tissue Doppler. The establishment of these objective PM measurements may be useful to evaluate morphological and functional abnormalities of the canine PM.

Surgical Repair of Ebstein's anomaly by Modified Carpentier's Method - 2 cases report - (변형적 Carpentier 방법에 의한 Ebstein 기형의 수술적 교정 -1 례 보고-)

  • Lee, Gun;Kim, Woong-Han;Lee, Chang-Ha;Na, Chan-Young;Jeong, Yoon-Seop;Jeong, Do-Hyun;Kim, Soo-Cheol;Lee, Young-Tak;Kim, Chong-Whan;Kim, Sung-Nok;Park, Young-Kwan
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.216-219
    • /
    • 1998
  • Ebstein's anomaly is a complex malformation that can be treated by various surgical techniques, either repair or replacement of the abnormal tricuspid valve, with variable results. The essence of the malformation is the downward displacement of the septal and posterior leaflets into the ventricle, resulting in the formation of an atrialized portion of the right ventricle. The aim of surgical repair is to correct the tricuspid valve dysfunction and to plicate the atrialized portion of the right ventricle A 12-months old female was admitted with the diagnosis of Carpentier type A of Ebstein's anomaly with severe tricuspid regurgitation. She successfully underwent operation with vertical plication of right ventricle and reimplantation of tricuspid leaflets. Postoperatively cardiac size was significantly reduced and tricuspid regurgitation was trivial in echocardiography. She was diacharged the 14th postoperative day.

  • PDF

The Distribution Structure of the Internet Movie and Spatial Clustering of the Internet Movie Industry (인터넷 영화의 유통구조와 인터넷 영화산업의 공간적 집적화)

  • Lee, Hee-Yeon;Lee, Nan-Kyung
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.107-130
    • /
    • 2005
  • The purpose of this study were to examine the spatial distribution and locational characteristics of the Internet movie industry, to seize the value chains of the Internet movie industry and distribution structure of the internet movies, and to analyze the vertical-horizontal linkages of the Internet movie firms and their spatial clustering. Recently, the Internet movie industry has developed rapidly due to the development of techniques related to movie contents, the broadband Internet and a wide expansion of the high speed communication network and the increase of demands on movie contents. It has been found that 74$\%$ of the Internet movie industry was concentrated in Seoul. Especially this industry was quite agglomerated in several dongs of Gangnam-gu such as Yoeksam, Nonhyeon, Daechi and Samseung. The proximity of the same or similar business firms was the primary locational factors that influenced on the Internet movie industry, followed by other factors such as convenience of transportation, the reputation of the place, and proximity of technically supporting firms. The Internet movie industry had the valve chain composed of 'contents suppliers $\rightarrow$ contents distributors $\rightarrow$ service providers', However, there were also a complex network of the VOD copyright owner, VOD syndicator, and service providers in each category of the value chain. This research clearly revealed that the localized clustering has been formed with the movie contents providers, technically supporting firms, client firms, and cooperative-affiliated business firms related to the Internet movie industry, Additionally, a very intimate network has been established within the clustering, inducing the enlargement of the market and decrease of costs, the co-sharing of tacit knowledge, and the synergy effect.

  • PDF

Operation and Result Analysis of Hydraulic Vehicle Holding Device (발사체 지상고정장치 유압시스템 작동 시험 및 결과 분석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jae Jun;Song, Oh-Seob;Lee, Young-Shin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.80-88
    • /
    • 2018
  • The function of a vehicle holding device (VHD) is to securely hold a launch vehicle on the launch pad and release the launch vehicle at maximum thrust after engine ignition to allow lift-off of the launch vehicle. During the release of the launch vehicle, to prevent the Ka doing a doing a doing mode, which is the vertical oscillation of the entire liquid propellant, the release of the launch vehicle should be gradual. In this study, for the gradual release of a launch vehicle, a hydraulic system comprising an accumulator and pyro valve to operate a hydraulic cylinder and control the speed of the cylinder with an orifice is introduced. Through a test, the influence of design variables on the cylinder speed is analyzed. Based on this, the design values of the hydraulic cylinder are determined. Through this study, the engineering basis for developing a VHD releasing a launch vehicle at maximum thrust is provided.

Design and simulation of hydraulic system for launch vehicle holding device (우주발사체 지상고정장치 유압시스템 설계 및 해석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jaejun;Kim, Bum Suk;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1087-1094
    • /
    • 2016
  • The responsibility of the vehicle holding device (VHD) is to hold the launch vehicle while it is stayed on launch pad and release the holding mechanism to allow a lift-off of launch vehicle at a moment of lift-off. During a release of the holding mechanism, in order to prevent the Ka doing a doing a doing mode which is vertical oscillation of entire liquid propellant and very severe for vehicle structure, gradual release of holding force is required. Also, a release operation of all 4 VHD should be synchronized very precisely. In this study, to comply the "gradual release and synchronized operation requirement", concept of VHD hydraulic system using an accumulator, pyro valve and orifice to control speed of hydraulic cylinder is proposed instead of using complicated hydraulic components. Then through multi-body dynamic analysis and computational hydraulic analysis, a size of orifice to meet a target speed of hydraulic cylinder is calculated. Through this study, simple and reliable VHD hydraulic system complying requirements is designed.

Minimally Invasive Cardiac Surgery -Lower half sternotomy- (최소 침습적 심장수술 -흉골하부절개술에 의한-)

  • 최강주;김병훈;이양행;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.379-382
    • /
    • 1999
  • Background: There are several advantages to the ministernotomy approach. The skin incision is much smaller than the traditional median sternotomy incision. This approach allows the patients to return to normal life more quickly and provide them with good self-image. Material and Method: From April to July 1998, we performed a ministernotomy via lower half sternum in 25 patients. There were 10 males(40%) and 15 females(60%) with a mean age of 30${\pm}$16 years(range 3 to 55 years). The body surface area ranged from 0.58 to 1.9 m2(mean 1.5 to 0.4 m2). A vertical skin incision of 11cm in mean length was made in the midline over the sternum extending inferiorly from the third intercostal space. The sternum was divided vertically in the midline from the xyphoid process to the level of second intercostal space using a standard saw and then transversely to the left(n=17) or to both sides(n=4) of the second intercostal space using an oscillating saw. The sternum was divided vertically only in children (n=4). Result: The ministernotomy was used in 25 consecutive patients undergoing mitral valve replacement(n=10), repair of ventricular septal defect(n=4) and atrial septal defect(n=11). There was no significant complication related to ministernotomy. The mean ICU stay time 20 hours. Patient and family acceptance was very high. Conclusion: We concluded that minimally invasive cardiac surgery via ministernotomy can be done safely. These methods may benefit the patients with lesser discomfort, smaller incision, and earlier ICU discharge than the traditional incision.

  • PDF

Analysis of Changes in Paleoenvironment using Diatoms from Iselin Bank in the Ross Sea (로스해 Iselin Bank에서 규조를 이용한 고해양 환경변화 해석)

  • Bak, Young-Suk;Kim, Sunghan;Lee, Jae Il;Yoo, Kyu-Cheul;Lee, Min Kyung
    • Journal of the Korean earth science society
    • /
    • v.42 no.6
    • /
    • pp.677-687
    • /
    • 2021
  • In this study, we analyzed diatoms from core RS15-GC41 collected in Iselin Bank, Ross Sea. A total of 24 genera and 35 species of diatoms are identified, and the having valve abundance of diatoms varies from 0.2 to 28.6×106/g. Four diatom assemblage zones are established by the vertical distribution of diatoms, and changed with a cycle of 100 kyrs. RS15-GC41 were deposited over the last 400 kyrs (corresponding to Marine Isotope Stages 1-11). The open-water species Fragilariopsis kerguelensis, Rhizosolenia styliformis, and Thalassionema nitzschioides abundantly occurred in interglacial periods. Whereas, Actinocyclus actinochilus abundantly dominant during the glacial periods. The distribution of these diatoms indicated, it can be seen that the sea-ice extent was larger and lasted longer during MIS 7, 9, and 11 than that of MIS 1, 3, and 5. Moreover, Paralia sulcata was abundantly predominant in MIS 7, 9, and 11; this finding suggests likely indicating that P. sulcata was transported from the coastal/inner shelf area to the study site, during accumulated in the sediments, reworked with the influx of ice-rafted debris by the currents

Estimation of Groundwater Table using Ground Penetration Radar (GPR) in a Sand Tank Model and at an Alluvial Field Site (실내 모형과 현장 충적층에서 지하투과레이더를 이용한 지하수면 추정)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Choi, Doo-Houng;Koh, Yong-Kwon
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.201-216
    • /
    • 2013
  • Ground penetrating radar (GPR) surveys were conducted in a sand tank model in a laboratory and at an alluvial field site to detect the groundwater table and to investigate the influence of saturation on GPR response in the unsaturated zone. In the sand tank model, the groundwater table and saturation in the sand layer were altered by injecting water, which was then drained by a valve inserted into the bottom of the tank. GPR vertical reflection profile (VRP) data were obtained in the sand tank model for rising and lowering of the groundwater table to estimate the groundwater table and saturation. Results of the lab-scale model provide information on the sensitivity of GPR signals to changes in the water content and in the groundwater table. GPR wave velocities in the vadose zone are controlled mainly by variations in water content (increased travel time is interpreted as an increase in saturation). At the field site, VRP data were collected to a depth of 220 m to estimate the groundwater table at an alluvial site near the Nakdong river at Iryong-ri, Haman-gun, South Korea. Results of the field survey indicate that under saturated conditions, the first reflector of the GPR is indicative of the capillary fringe and not the actual groundwater table. To measure the groundwater table more accurately, we performed a GPR survey using the common mid-point (CMP) method in the vicinity of well-3, and sunk a well to check the groundwater table. The resultant CMP data revealed reflective events from the capillary fringe and groundwater table showing hyperbolic patterns. The normal moveout correction was applied to evaluate the velocity of the GPR, which improved the accuracy of saturation and groundwater table information at depth. The GPR results show that the saturation information, including the groundwater table, is useful in assessing the hydrogeologic properties of the vadose zone in the field.