• 제목/요약/키워드: vertical stiffness

Search Result 649, Processing Time 0.026 seconds

Effect of connection modeling on the seismic response of steel braced non-moment resisting frames

  • Bagheri, Saman;Tabrizi, Navid Vafi
    • Structural Engineering and Mechanics
    • /
    • 제68권5호
    • /
    • pp.591-601
    • /
    • 2018
  • Non-moment beam-to-column connections, which are usually referred to as simple or shear connections, are typically designed to carry only gravity loads in the form of vertical shears. Although in the analysis of structures these connections are usually assumed to be pinned, they may provide a small amount of rotational stiffness due to the typical connection details. This paper investigates the effects of this small rotational restraint of simple beam-to-column connections on the behavior and seismic response of steel braced non-moment resisting frames. Two types of commonly used simple connections with bolted angles, i.e., the Double Web angle Connection (DWC) and Unstiffened Seat angle Connection (USC) are considered for this purpose. In addition to the pinned condition - as a simplified representation of these connections - more accurate semi-rigid models are established and then applied to some frame models subjected to nonlinear pushover and nonlinear time history analyses. Although the use of bracing elements generally reduces the sensitivity of the global structural response to the behavior of connections, the obtained results indicate considerable effects on the local responses. Namely, our results show that consideration of the real behavior of connections is essential in designing the column elements where the pin-connection assumption significantly underestimates design of outer columns of upper stories.

Study on the mechanical behaviors of timber frame with the simplified column foot joints

  • Yang, Qing-shan;He, Jun-xiao;Wang, Juan
    • Structural Engineering and Mechanics
    • /
    • 제77권3호
    • /
    • pp.383-394
    • /
    • 2021
  • Column foot in traditional Chinese timber structures may be subjected to be uplifted due to the lateral load and subsequently reset under the vertical loads. The residual moment of the rocking column foot is the most important parameter representing the mechanical behaviors of column foot, and the simplification of joints is the basis of structural analysis of whole structure. The complicated mechanical behaviors of joint and the modeling of the column foot joint has been undertaken historically based on the experiments and numerical simulation. On the condition of limited application range of those models, a lack of simplified model to represent the mechanical behaviors of joint deserves attentions. There is a great need to undertake theoretical studies to derive the residual moment and make better simplified model of the joint. This paper proposes the residual moment and equivalent simplified model of the rotational stiffness for column foot joint. And, the timber frame is established based on the simplified model, which is verified by solid finite element model. Results show that a mutual agreement on the mechanical behaviors of the timber frame is obtained between the simplified model and the solid finite element model. This study can serve as the references of the structural analysis for the traditional timber structures.

인장철근배근량에 따른 U-플랜지 트러스 복합보의 휨 내력에 관한 실험연구 (Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam According to Reinforcement Amounts)

  • 오명호;박성진;김영호
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.33-40
    • /
    • 2021
  • For the practical application of U-flanged Truss Hybrid beams, the flexural capacity of hybrid beams with end reinforcement details using vertical steel plates was verified. The bending test of U-flanged Truss Hybrid beams was performed using the same top chord under the compressive force, but with the thickness of the bottom plate and the amount of tensile reinforcement. The initial stiffness and maximum load of the specimen with tensile reinforcement have a higher value than that of the specimen without tension reinforcement, but the more tensile reinforcement, the greater the load decrease after the maximum load. In the case of the specimen with tensile reinforcement, because the test result value is 76% to 88% when compared with the flexural strength according to Korea Design Code, the safety of the U-flanged Truss Hybrid beam with the same details of the specimens can't ensure. Therefore, the development of new details is required to ensure that the bottom steel plate and the tensile reinforcement can undergo sufficient tensile deformation.

전단파괴모드를 고려한 철근콘크리트 보통전단벽-골조 건물의 붕괴메커니즘 (Collapse Mechanism of Ordinary RC Shear Wall-Frame Buildings Considering Shear Failure Mode)

  • 추유림;김태완
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.1-9
    • /
    • 2021
  • Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.

Experimental study on the asymmetric impact loads and hydroelastic responses of a very large container ship

  • Lin, Yuan;Ma, Ning;Gu, Xiechong;Wang, Deyu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.226-240
    • /
    • 2020
  • This paper presents an experimental investigation of asymmetric impact effects on hydroelastic responses. A 1:64 scaled segmented ship model with U-shape open cross-section backbone was newly designed to meet elastic similarity conditions of vertical, horizontal and torsional stiffness simultaneously. Different wave heading angles and wavelengths were adopted in regular wave test. In head wave condition, parametric rolling phenomena happened along with asymmetric slamming forces, the relationship between them was disclosed at first time. The impact forces on starboard and port sides showed alternating asymmetric periodic changes. In oblique wave condition, nonlinear springing and whipping responses were found. Since slamming phenomena occurred, high-frequency bending moments became an important part in total bending moments and whipping responses were found in small wavelength. The wavelength and head angle are varied to elucidate the relationship of springing/whipping loads and asymmetric impact. The distributions of peaks of horizontal and torsional loads show highly asymmetric property.

Effect of sequential earthquakes on evaluation of non-linear response of 3D RC MRFs

  • Oggu, Praveen;Gopikrishna, K.
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.279-293
    • /
    • 2021
  • Most of the existing seismic codes for RC buildings consider only a scenario earthquake for analysis, often characterized by the response spectrum at the specified location. However, any real earthquake event often involves occurrences of multiple earthquakes within a few hours or days, possessing similar or even higher energy than the first earthquake. This critically impairs the rehabilitation measures thereby resulting in the accumulation of structural damages for subsequent earthquakes after the first earthquake. Also, the existing seismic provisions account for the non-linear response of an RC building frame implicitly by specifying a constant response modification factor (R) in a linear elastic design. However, the 'R' specified does not address the changes in structural configurations of RC moment-resisting frames (RC MRFs) viz., building height, number of bays present, bay width, irregularities arising out of mass and stiffness changes, etc. resulting in changed dynamic characteristics of the structural system. Hence, there is an imperative need to assess the seismic performance under sequential earthquake ground motions, considering the adequacy of code-specified 'R' in the representation of dynamic characteristics of RC buildings. Therefore, the present research is focused on the evaluation of the non-linear response of medium-rise 3D RC MRFs with and without vertical irregularities under bi-directional sequential earthquake ground motions using non-linear dynamic analysis. It is evident from the results that collapse probability increases, and 'R' reduces significantly for various RC MRFs subjected to sequential earthquakes, pronouncing the vulnerability and inadequacy of estimation of design base shear by code-specified 'R' under sequential earthquakes.

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • 제77권6호
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

Research on the inlet preswirl effect of clearance flow in canned motor reactor coolant pump

  • Xu, Rui;Song, Yuchen;Gu, Xiyao;Lin, Bin;Wang, Dezhong
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2540-2549
    • /
    • 2022
  • For a pressurized water reactor power plant, the reactor coolant pump (RCP) is a kernel component. And for a canned motor RCP, the rotor system's properties determines its safety. The liquid coolant inside the canned motor RCP fills clearance between the metal shields of rotor and stator, forming a lengthy clearance flow. The influence of inlet preswirl on rotordynamic coefficients of clearance flow in canned motor RCP and their effects on the rotordynamic characteristics of the pump are numerically and experimentally investigated in this work. A quasi-steady state computational fluid dynamics (CFD) method has been used to investigate the influence of inlet preswirl. A vertical experiment rig has also been established for this purpose. Rotordynamic coefficients on different inlet preswirl ratios (IR) are obtained through CFD and experiment. Results show that the cross-coupled stiffness of the clearance flow would change significantly with inlet preswirl, but other rotordynamic coefficients would not change significantly with inlet preswirl. For the case of clearance flow between the stator and rotor cans, influence of inlet preswirl is not so significant as the IR is not large enough.

Modified Lysmer's analog model for two dimensional mat settlements under vertically uniform load

  • Chang, Der-Wen;Hung, Ming-He;Jeong, Sang-Seom
    • Geomechanics and Engineering
    • /
    • 제25권3호
    • /
    • pp.221-231
    • /
    • 2021
  • A two dimensional model of linearly elastic soil spring used for the settlement analysis of the flexible mat foundation is suggested in this study. The spring constants of the soils underneath the foundation were modeled assuming uniformly vertical load applied onto the foundation. The soil spring constants were back calculated using the three-dimensional finite element analysis with Midas GTS NX program. Variation of the soil spring constants was modeled as a two-dimensional polynomial function in terms of the normalized spatial distances between the center of foundation and the analytical points. The Lysmer's analog spring for soils underneath the rigid foundation was adopted and calibrated for the flexible foundation. For validations, the newly proposed soil spring model was incorporated into a two dimensional finite difference analysis for a square mat foundation at the surface of an elastic half-space consisting of soft clays. Comparative study was made for elastic soils where the shear wave velocity is 120~180 m/s and the Poisson's ratio varies at 0.3~0.5. The resulting foundation settlements from the two dimensional finite difference analysis with the proposed soil springs were found in good agreement with those obtained directly from three dimensional finite element analyses. Details of the applications and limitations of the modified Lysmer's analog springs were discussed in this study.

Research on a novel shear lead damper: Experiment study and design method

  • Chong, Rong; Wenkai, Tian;Peng, Wang;Qingxuan, Shi
    • Steel and Composite Structures
    • /
    • 제45권6호
    • /
    • pp.865-876
    • /
    • 2022
  • The slit members have lower strength and lower stiffness, which might lead to lower energy dissipation. In order to improve the seismic performance of the slit members, the paper proposes the shear lead damper, which has stable performance and small deformation energy dissipation capacity. Therefore, the shear lead damper can set in the vertical silts of the slit member to transmit the shear force and improve energy dissipation, which is suitable for the slit member. Initially, the symmetrical teeth-shaped lead damper was tested and analyzed. Then the staggered teeth-shaped lead dampers were developed and analyzed, based on the defect analysis and build improvements of the symmetrical specimen. Based on the parameter analysis, the main influence factors of hysteretic performance are the internal teeth, the steel baffles, and the width and length of damper. Finally, the theoretical analysis was presented on the hysteretic curve. And the skeleton curve and hysteresis path were identified. Based on the above theoretical analysis, the design method was proposed, including the damping force, the hysteresis model and the design recommendations.