• Title/Summary/Keyword: vertical shafts

Search Result 48, Processing Time 0.023 seconds

Effects of interface stiffness on dynamic behavior of connections between vertical shafts and tunnels under earthquake (지진 시 공동구용 수직구-터널 접속부 거동에 대한 경계면 강성 계수의 영향)

  • Kim, Jung-Tae;Hong, Eun-Soo;Kang, Seok-Jun;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.861-874
    • /
    • 2019
  • A great interest in the seismic performance evaluation of small size tunnel structures such as utility tunnel has been taken since recent earthquakes at Pohang and Gyeongju in Korea. In this study, the three-dimensional dynamic analyses of vertical shaft and horizontal tunnel under seismic load were carried out using FLAC3D. Especially, parametric analyses was performed to investigate the effects of interfacial stiffness on interfacial behavior between soil and structure. The parametric analysis showed that the interfacial stiffness scarcely gave an effect on the global dynamic behavior of the structure, while had a significant effect on the local displacement behavior of the connections. The magnitude of the interfacial stiffness was inversely proportional to the displacement, while the magnitude of interface stiffness was proportional to the normal and shear stresses. The results of this study suggest the limitations of the existing empirical equations for interfacial stiffness and emphasize the need to develop new interfacial stiffness models.

A Study on the Causes of Changes in Architectural Plan on the Prizewinner of General Hospital Design Competitions in Korea - Focused on the Architectural Fixed-Elements (국내 종합병원 설계경기 당선작의 설계 변경 원인에 관한 연구 - 건축 고정요소를 중심으로)

  • LU, XUZHENGYI;Kim, Sung Hyun;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.15-27
    • /
    • 2021
  • Purpose: This study compares and analyzes the design drawing changes that occur during the design process between hospital design competition and the final detailed design. Based on this, factors that can reduce the rate of changes in drawings are derived. The purpose is to provide basic data to lessen the rate of the changes in the process of architecture design and can be reflected in the design competition guidelines. Methods: In this study, cases of hospitals are selected which are built in 5 recent years. Then compare and analyze the drawings which was drawn in the process from submission of competition to final design. After investigating the design changes that occur after the design competition, analyze the fixed-elements which are the main causes of design changes. Fixed-elements can be narrow down into few architecture-factors such as vertical-core, shafts, public-corridor, HAVC, and mechanical/electrical spaces. Results: Result of the rate of changes in each selected hospital floors can be sorted into variable-elements and fixed-elements which tells that the higher the rate of changes of the fixed-elements, the higher the rate of changes of the variable-elements. Implications: In other words, it can be said as the lower the change rates of the fixed-element, lower changes in whole design changes which represents that the greater the efficiency can be shown in the design process.

A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct (공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구)

  • Jo, Hyeong-Je;Jun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.145-160
    • /
    • 2018
  • Long subsea tunnel is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for tunnel ventilation. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. As a result, ventilation distance become longer and supply airflow becomes excessive due to air leakage, So, duct mounting for temporary ventilation is impossible or fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In previous study, we have found that air leakage is the key factor in solving these problems and experimental results show that the new connection method has a leakage rate of about $1.46mm^2/m^2$ (Jo et al., 2017). In this study, we present the experimental results of the measurement of the leakage rate of the prototype with the new connection method, and analyze experimentally the improvement of the leakage rate when applying the flexible cover inside the duct to improve the leakage performance of the existing connection method.

The Feasibility of Natural Ventilation in Radioactive Waste Repository Using Rock Cavern Disposal Method (동굴처분 방식을 사용하는 방사성 폐기물 처분장의 자연 환기 타당성 평가)

  • Kim Jin;Kwon Sang Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.183-192
    • /
    • 2005
  • Natural ventilation in radioactive waste repositories is considered to be less efficient than mechanically forced ventilation for the repository working environment and hygiene & safety of the public at large, for example, controlling the exposure of airborne radioactive particulate matter. It is, however, considered to play an important role and may be fairly efficient for maintaining environmental conditions of the repository over the duration of its lifetime, for example, moisture content and radon (Rn) gas elimination in repository. This paper describes the feasibility of using natural ventilation which can be generated in the repository itself, depending on the conditions of the natural environment during the periods of repository construction and operation. Evidences from natural cave analogues, actual measurements of natural ventilation pressures in mountain traffic tunnels with vertical shafts, and calculations of airflow rates with given natural ventilation pressures indicate possible benefits from passive ventilation for the prospective Korean radioactive waste repository. Natural ventilation may provide engineers with a cost-efficient method for heat and moisture transfer, and radon (Rn) gas elimination in a radioactive waste repository. The overall thermal performance of the repository may be improved. The dry-out period may be extended, and the seepage flux likely would be decreased.

  • PDF

A Study on the Design of Rotary Mower and Its Utilization. (Rotary Mower의 제작과 그 이용에 관한 연구)

  • 최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3897-3920
    • /
    • 1975
  • Since the most of Korean dairy and cattle raising farms are too small to introduce western mechanized farming, it is necessary to develope small size equipments. This study has been carried to develop a rotary mower as on attachment of 8 to 10 horse powertiller which is widely spread in rural area. It will not ony be helpfull for the farmers to harvesting hay grass but also desirable to increase the power tiller utility. The protto type rotary mower designed through the fundamental investigations, has been modified and improved through the field trials, and a series of field tests has been carried to investigate its performance and economic feasibility comparing with existing vailable harvesting equipments. The results are as follows; 1. To increase the stability, two guide wheels are attached to both side of the protto type rotary mower. 2. To prevent the clinging of tall grasses, the vertical driving shafts are covered with cylindrical protectors. 3. The cutting height is adjustable in 8 steps from 2.5 to 20 centimeters by changing the length of guide wheel legs. 4. The practical Critical cutting speed were always higher than theoretical value in both case of single cutting blade and three when the cutting depth was 25 millimeter. 5. The peripheral speed of cutting blade was varied in response to the change of engine speed, mean while the peripheral speed was adequate as it was changhed from 25 to 35 meter per second when the power tiller is operated in proper working ground speed. 6. The time requirement to harvest 10 a were 88.7, 54.6 and 41.4 minutes for the first, second and third stage of ground speed respectively, and because of the difficulty of delivery, it was observed that operating with fourth stage of ground speed was not recomanendable when the grass height is taller than 90 centimeters. 7. The performance of rotary mower were 1.1-1.7, 1.4-4.0, 3.8-11.8 and 7.4-22.0 times of reciprocating mower, portable disc type cutter, hay scythe and ordinary sickle respectively. 8. When the slope exceeds, 20 degree the downward harvesting operation was impossible because of the excessive front end weight, while less than 5 degree of land slope did not effect in field operation. 9. Increased traveling spee caused higher cutting height and slight cutting failure, but seems not to effect to the gross yield, and the efficiency of cutting width were from 83 to 94 precent. 10. Tn rank of economy were rotary mower (3,2 stage operation), reciprocating mower, hay scythe, portable disc type cutter and sickle in order when the annul operation exdeeds 100 hours. From the above results, it is convinced that the protto type rotary mower is good enough to the livestock farmers as a hay harvesting equipment because of its economy, hardiness in operating and its out standing performance and hopefully it will contribute to the extension of Korean livestock farming.

  • PDF

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation (건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구)

  • Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

The Characteristics of Flexibility applied to Unit Plan of Housing by Residents Participation - focusing on European Multi-story Housing applying Residents Participation - (거주자 참여형 공동주거의 평면계획에 적용된 가변성의 특성 - 유럽의 거주자 참여형 다층 공동주거를 중심으로 -)

  • Kim, Hyun-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.113-123
    • /
    • 2018
  • First of all, the multi-story Housing applying resident's participation in europe was classified by the menu selection method, the two-step supply method and the cooperative method. And then I analyzed flexible unit plan of cases for deriving the planning methode and the characteristics of flexibility. First, I analyzed the area and form of the unit plan, structure and Installation, fixed and variable elements to derive the planning method. The area of units are distributed from a minimum of $35m^2$ to a maximum of $150m^2$, and many of the unit planes have a narrow front and a deep depth. The structure is a long-span wall-structure or a skeleton structure, and is designed without any columns and bearing walls in the interior space for flexibility in spatial composition. The vertical shafts are located in the center of the unit in a box-form or in the corner at the unit dividing wall for free placement of interior wall. Fixed elements are framework and facility systems. Most of the future residents in the two-steps supply method and the cooperative method were able to freely design the internal space within the zoning concept proposed by the architect and change the location of the facade element within module system proposed by the architect. Second, the characteristics of the flexibility applied to the unit plan were divided in integrated flexibility, functional flexibility, construction flexibility, and supply flexibility. The integrated flexibility enables residents to give the variable space combination based on the complex structure of the inner space for providing various living experiences. Regarding functional flexibility, the three-dimensional spatial structure with neutral space has multi-functionality according to the needs of residents and easily accepts mixing of hybrid programs such as work and residence. Constructive flexibility allows residents to create identity by freely planning interior space and changing the size or location of facade components in a determined system of architects. Finally, various types of size and space composition are proposed and realized in the whole building applying menu selection method, so that flexibility in the offer can accommodate and integrate various types of living.