• Title/Summary/Keyword: vertical drain method

Search Result 113, Processing Time 0.022 seconds

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (연직드레인 공법에 의한 연약지반의 압밀거동)

  • 이달원;강예묵
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.376-381
    • /
    • 1998
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system 1. The relation of measurement settlement( $S_{m}$) versus design settlement( $S_{t}$) and measurement consolidation ratio( $U_{m}$) versus design consolidation ratio( $U_{t}$) were shown $S_{m}$=(1.0~l.1) $S_{t}$, $U_{m}$=(1.13~l.17) $U_{t}$, at 1.0m drain spacing and $S_{m}$=(0.7~0.8) $S_{t}$, $U_{m}$=(0.92~0.99) $U_{t}$ at 1.5m drain spacing, respectively. 2. The relation of field compression index( $C_{cfield}$) and virgin compression index( $V_{cclab}$) was shown $C_{cfield}$=(1.0~1.2) $V_{cclab}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio( $C_{h}$/ $C_{v}$) were $C_{h}$=(2.4 ~ 3.0) $C_{v}$. $C_{h}$=(3.5 ~ 4.3) $C_{v}$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacingngasing of drain spacingng spacingng

  • PDF

A Assessment of Discharge Capacity of Vertical Drains and Smear Zone Effect from Model Test (실내모형시험을 통한 연직배수재의 통수능력 및 스미어존 영향 평가)

  • Chun, Byung-Sik;Kim, Eui-Seok;Do, Jong-Nam;Kuk, Kil-Keun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1136-1143
    • /
    • 2008
  • The Vertical Drains(Sand Drains, Pack Drain, PBD) is used for Vertical Drains Method in domestic. Each of the drains is selected after it consider a field condition and efficiency of drain. A discharge capacity is very important factor, which to estimate a efficiency. And the smear Zone where disturbance area of in-suit by installation of Vertical Drains is important factor to select a drains. In this study, the complex discharge capacity test was operated for discharge capacity comparison of the Wing Drain and PBD. And a model test was operated to apprehend smear zone of the Wing Drain and PBD. From these tests, it was apprehended an engineering characteristic of vertical drain. The results of the complex discharge capacity test, a discharge capacity fell below $20cm^3/sec$ to $1cm^3/sec$ in more than overburden load $2.5kg/cm^2$. The Wing Drain maintained a over $40cm^3/sec$ in more than overburden load $2.5kg/cm^2$ and minimum discharge capacity $8cm^3/sec$. The results of the smear zone test, a influence bounds of smear zone was more larger in case of the Wing Drain(rectangle) than the PBD. But when a discharge capacity of Wing Drain is considered, it was concluded which smear zone bounds difference was effected in comparison with PBD. I think that it minimized a mandrel section to minimize a smear zone effect range

  • PDF

한국에서의 PBD공법의 현황 및 문제점과 발전방향

  • 김영남;권성진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.65-94
    • /
    • 2001
  • The use of PBD(prefabricated band drain)far ground improvement is rapidly increased due to the merit of construction period and cost, environmental preservation compared with other vertical drain method, and the development of material. This paper presents the historical review, theoretical background, design procedure and method, and typical construction example for the PBD. Also, the direction of further technical development and study is recommended.

  • PDF

A Study on the Effect of Improvement Boundary of Vertical Drain Method by Finite Element Analysis (유한요소해석을 이용한 연직배수재의 타설범위에 따른 개량효과에 관한 연구)

  • Chang, Y.C.;Kim, J.H.;Lee, J.S.
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.5-12
    • /
    • 2004
  • Soft foundation is extensively distributed in coastal areas including our local regions. Embankment load on such soft foundation causes displacement due to lack of base ground supports. Long-term consolidation can result in settlement and destruction of shear failure and structure. Therefore, a variety of vertical drain methods are applied to construction sites to prevent base from breaking and changing for secure construction. This study analyzed the patterns of changes displacement to determine efficient range of improvement since range of vertical drain material determines vertical and horizontal changes based on the width range of under ground improvement. Changes of intensity with distance from embankment edge were also analyzed in the field study of embankment slope.

  • PDF

Required Discharge Capacity for Horizontal Drains Installed with Vertical Drains (연직배수공법에서 수평배수층의 소요통수능)

  • 김현태;김상규;공길용
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.1
    • /
    • pp.59-70
    • /
    • 2002
  • Horizontal drains are sometimes installed on the ground together with vertical drains in order to drain excess pore water. Taking into account the discharge capacity of horizontal drains, a new analytical method is developed in this paper, and then a new formula for the discharge capacity of horizontal drains is proposed. It is known from the analysis that the effect of the rate of surcharge loading is negligible in determining horizontal discharge capacity. This formula is described as the function of coefficient of consolidation, space of vertical drain, compression index, length of horizontal drains, and thickness of the compressible layer.

Deformation Analysis of Soft Foundation with Vertical Drain Wells using the Interface Element Method -With Emphasis on Model Foundation and Actual Sand Drain Well Foundation- (접합요소에 의한 Vertical Drain Well 지반의 변형해석 - 모델지반과 실제 Sand Drain Well 지반을 중심으로 -)

  • Lee, Jean Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.227-237
    • /
    • 1993
  • This paper dealt with numerical analysis of sand drain considering the smear effect around drain wells and discontinuous deformation behavior due to difference in rigidity between drain materials and adjacent clayey soils. Biot's equation was selected as governing equation coupled with MODCAM (Modified Cam-clay) model or EVP(Elasto-Viscoplastic) model as constitutive equation. The validity as well as the accuracy of the method developed by author was checked by comparing the proposed method with those by Siriwardane and Ghaboussi using joint element. The FEM analysis developed in this study was applied to both 2-dimensional model foundation and actual foundation. the result of which proved to be satisfactory.

  • PDF

A study on the analysis of a vertical V-groove junction field effect transistor with finite element method (유한요소법에 의한 V구JFET의 해석에 관한 연구)

  • 성영권;성만영;김일수;박찬원
    • 전기의세계
    • /
    • v.30 no.10
    • /
    • pp.645-654
    • /
    • 1981
  • A technique has been proposed for fabricating a submicron channel vertical V-groove JFET using standard photolithography. A finite element numerical simulation of the V-groove JFET operation was performed using a FORTRAN progrma run on a Cyber-174 computer. The numerical simulation predicts pentode like common source output characteristics for the p$^{+}$n Vertical V-groove JFET with maximum transconductance representing approximately 6 precent of the zero bias drain conductance value and markedly high drain conductance at large drain voltages. An increase in the acceptor concentration of the V-groove JFET gate was observed to cause a significant increase in the transconductance of the device. Therefore, as above mentioned, this paper is study on the analysis of a Vertical V-groove Junction Field Effect Transistor with Finite Element Method.d.

  • PDF

A study on evaluation of duplex loading pressure in Suction Drain Method (Suction Drain 공법에서 양방향 압력재하에 의한 효율 평가에 관한 연구)

  • Ahn, Dong-Wook;Chae, Kwang-Seok;Han, Sang-Jae;Yoon, Myung-Seok;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1256-1263
    • /
    • 2010
  • Suction Drain Method is soft ground improvement technique, in which a vacuum pressure can be directly applied to the Vertical Drain Board to promote consolidation and strengthening the soft ground. This method does not require a surcharge load, different to embankment or Preloading Method. In this study, ground improvement efficiency of suction drain method was estimated when duplex loading pressure with vacuum and pressure. During suction drain method process, surface settlement and pore pressure were monitored, and cone resistance test as well as water content were also measured after the completion of Suction Drain Method treatment.

  • PDF

Design of Vortical Drain in consideration of Smear Effect and well Resistance (교란효과와 배수저항을 고러한 연직 배수재의 설계)

  • 김태우;강예묵;이달원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.438-443
    • /
    • 1998
  • In this study, compared the degree of consoildation of vertical drain considering variation of smear effect and well resistance with that of hyperbolic and curve fitting method. It applied Barren, Yoshikuni, Hansbo, Onoue's theory for the consolidation of vertical drain, and compared differences of theoretical curve by comparing with measured value, and finded out the extent of smear effect and well resistance.

  • PDF