• 제목/요약/키워드: vertical dampers

검색결과 65건 처리시간 0.022초

Analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Dongping
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.355-366
    • /
    • 2019
  • Self-centering wall (SCW) is a resilient and sustainable structural system which incorporates unbonded posttensioning (PT) tendons to provide self-centering (SC) capacity along with supplementary dissipators to dissipate seismic energy. Hysteretic energy dissipators are usually placed at two sides of SCWs to facilitate ease of postearthquake examination and convenient replacement. To achieve a good prediction for the skeleton curve of the wall, this paper firstly developed an analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers (VD-SCWs) using the concept of elastic theory. A simplified method for the calculation of limit state points is developed and validated by experimental results and can be used in the design of the system. Based on the analytical results, parametric analysis is conducted to investigate the influence of damper and tendon parameters on the performance of VD-SCWs. The results show that the proposed approach has a better prediction accuracy with less computational effects than the Perez method. As compared with previous experimental results, the proposed method achieves up to 60.1% additional accuracy at the effective linear limit (DLL) of SCWs. The base shear at point DLL is increased by 62.5% when the damper force is increased from 0kN to 80kN. The wall stiffness after point ELL is reduced by 69.5% when the tendon stiffness is reduced by 75.0%. The roof deformation at point LLP is reduced by 74.1% when the initial tendon stress is increased from $0.45f_{pu}$ to $0.65f_{pu}$.

Numerical performance assessment of Tuned Mass Dampers to mitigate traffic-induced vibrations of a steel box-girder bridge

  • Bayat, Elyas;Bayat, Meysam;Hafezzadeh, Raheb
    • Structural Engineering and Mechanics
    • /
    • 제78권2호
    • /
    • pp.125-134
    • /
    • 2021
  • In this paper, the effects of Tuned Mass dampers (TMDs) on the reduction of the vertical vibrations of a real horizontally curved steel box-girder bridge due to different traffic loads are numerically investigated. The performance of TMDs to reduce the bridge vibrations can be affected by the parameters such as dynamic characteristics of TMDs, the location of TMDs, the speed and weight of vehicles. In the first part of this study, the effects of mass ratio, damping percentage, frequency ratio, and location of TMDs on the performance of TMDs to decrease vertical vibrations of different sections of bridge deck are evaluated. In the second part, the performance of TMD is investigated for different speeds and weights of traffic loads. Results show that the mass ratio of TMDs is the more effective parameter in reducing imposed vertical vibration in comparison with the damping ratio. Furthermore, it is found that TMD is very sensitive to its tuned frequency, i.e., with a little deviation from a suitable frequency, the expected performance of TMD significantly decreased. TMDs have a positive and considerable performance at certain vehicle speeds and this performance declines when the weight of traffic loads is increased. Besides, the results reveal that the highest impact of TMD on the reduction of the vertical vibrations is when free vibrations occur for the bridge deck. In that case, maximum reductions of 24% and 59% are reported in the vertical acceleration of the bridge deck for the forced and free vibration amplitudes, respectively. The maximum reduction of 13% is also obtained for the maximum displacement of the bridge deck. The results are mainly related to the resonance condition.

Comparison of different distributions of viscous damper properties in asymmetric-plan frames

  • Landi, Luca;Molari, Andrea;Diotallevi, Pier Paolo
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.233-248
    • /
    • 2020
  • In this article, one of the procedures to design viscous dampers proposed in literature is applied to 3D asymmetric-plan buildings, considering different distributions for the damping coefficients, which are assumed to be proportional to specific structural or response parameters. The main purpose was to investigate the effectiveness of different vertical and in-plan distributions of the damping coefficients of nonlinear viscous dampers for the seismic retrofit of existing buildings. For comparison purposes, all the distributions were applied utilizing both a simplified and an extended method for the 3D structures, where the simplified method takes into account only the translation in the seismic direction, and the extended method considers the translations along the two orthogonal directions together with the floor rotations. The proposed distributions were then applied to a typical case study involving an asymmetric-plan six-storey RC building. The effectiveness of the different distributions was examined through time-history analyses, assuming nonlinear behaviour for both the viscous dampers and the structural elements. The results of the nonlinear dynamic analyses were examined in terms of maximum and residual inter-storey drifts, peak floor accelerations and maximum damper forces.

Seismic retrofit of structures using added steel column friction dampers

  • Mohammad Mahdi Javidan;Asad Naeem;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제49권3호
    • /
    • pp.257-270
    • /
    • 2023
  • In this study, the feasibility and applicability of a friction damper with a vertical installation scheme are investigated. This device is composed of a steel section and two friction hinges at both ends which dissipate seismic energy. Due to its small width and vertical installation scheme, the proposed damper can minimize the interference with architectural functions. To evaluate the performance of the proposed damper, its mechanical behavior is theoretically evaluated and the required formulas for the yield strength and elastic stiffness are derived. The theoretical formulas are verified by establishing the analytical model of the damper in the SAP2000 software and comparing their results. To further investigate the performance of the developed damper, the provided analytical model is applied to a 4-story reinforced concrete (RC) structure and its performance is evaluated before and after retrofit under the Maximum Considered Earthquake (MCE) hazard level. The seismic performance is thoroughly evaluated in terms of maximum interstory drift ratio, displacement time history, residual displacement, and energy dissipation. The results show that the proposed damper can be efficiently used to protect the structure against seismic loads.

Vertical uplift of suspension equipment due to hanger slackening: Experimental and numerical investigation

  • Yang, Zhenyu;He, Chang;Mosalam, Khalid M.;Xie, Qiang
    • Structural Engineering and Mechanics
    • /
    • 제82권6호
    • /
    • pp.735-745
    • /
    • 2022
  • The suspension thyristor valve can generate tremendous vertical acceleration responses in layers and large tension forces in hangers. A shaking table test of a scaled-down model of thyristor valves suspended on a hall building is performed to qualify the risk of vertical uplift of two representative types of valves, the chain valve and the rigid valve. Besides, an analytical model is established to investigate the source of the slackening of hangers. The test results show that the valves frequently experience a large vertical acceleration response. The soft spring joint can significantly reduce acceleration, but is still unable to prevent vertical uplift of the chain valve. The analytical model shows a stiffer roof and inter-story connection both contribute to a higher risk of vertical uplift for a rigid valve. In addition, the planar eccentricity and short hangers, which result in torsional motion of the valve, increase the possibility of vertical uplift for a chain valve. Therefore, spring joints with additional viscous dampers and symmetric layout in each layer are recommended for the rigid and chain valve, respectively, to prevent the uplift of valves.

실차 시험을 통한 ER 현가장치의 성능평가 (Rerformance Evaluation of ER Suspensions Under Field Test)

  • 이헌균;최승복;한승직;장유진;이성범
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.347-354
    • /
    • 2000
  • This paper presents performance characteristics of a semi-active suspension featuring continuously variable ER (electro-rheological) dampers. These are evaluated through the field test of a passeng er car. Four ER dampers (two for front and two for rear part) are manufactured and their field-dependent damping properties are experimentally investigated. The damping force responses to step input fields are also identified by employing small size of high voltage amplifiers which are made adaptable to the field test. A skyhook controller considering the vertical, pitch and roll motions is formulated and incorporated with a car to be tested. The field test is then undertaken in order to evaluate both comfortability and steering stability showing bump, dive and squat responses.

에너지 소산형 감쇠기를 이용한 철근콘크리트 전단벽-골조 시스템의 진동제어 (Vibration Control of Shear Wall-Frame System using Energy Dissipation Devices)

  • 박지훈;김길환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.578-581
    • /
    • 2007
  • In this study, the seismic control performance of energy dissipation devices installed in a shear all-frame structure is investigated through nonlinear time history analysis of a 12-story building. Inelastic shear walls are modeled using the multiple vertical line element model (MVLEM) and inelastic columns and girders were modeled using fiber beam elements. For a seismic load increased by 38% compared to the design load, the seismic control performance was analyzed based on the results of a nonlinear time history analysis in terms of the inter-story drift, the story shear and the flexural strain. Friction type dampers was found to performs best if they are installed in the form of a brace adjacent to the shear wall with the friction force of 15 % of the maximum story shear force induced in the original building structure without dampers.

  • PDF

경부고속철도 시험선 구간에서 G7 고속전철 차량의 동특성 검토 (Review on the Dynamic Behavior of G7 High Speed Train(KHST) in the KTX Test Line)

  • 박찬경;김영국;배대성;박태원
    • 한국철도학회논문집
    • /
    • 제4권4호
    • /
    • pp.131-137
    • /
    • 2001
  • The dynamic behavior of high speed train is very important because of its safety and passengers' ride comfort. The railway vehicle is composed of many suspension components, such as 1st springs, 1st dampers, 2nd springs and 2nd dampers, that have an influence on the dynamic characteristics of high speed train. Also, the wheel/rail shapes and the track geometry affect the dynamic behavior of high speed train. This paper reviews the dynamic behavior of KHST in the KTX test line. The VAMPIRE program is used for this simulation. The simulation results are within the limits of safety criteria. Thus the KHST can operate safely at 350 km/h in the KTX test line.

  • PDF

탄소성 이력댐퍼를 구비한 접합부의 거동 (Structural Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers)

  • 오상훈;유홍식;김영주
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.552-559
    • /
    • 2005
  • The resistance of a structure against an earthquake is related to its ability to absorb the seismic input energy. The development of devices for dissipating the seismically induced energy on the structure is a subject that is receiving large attentionin the field of earthquake engineering. One example of these devices is the steel plate with slits. In this paper, a connection with a slit-type steel plate damper installed at each ends of wide-flange section beam, as an energy absorption element, was proposed. A series of experiment was performed to investigate their behavior and structural characteristic. The main parameters were the aspect ratio of the struts in slit plates, thickness of the struts and height of the vertical plates. Test results indicated that most of the energy was absorbed by plastic deformation of slit plate dampers.

  • PDF

MR 댐퍼를 이용한 구급차의 환자용 Bed Stage 설계 및 제어 (Design and Control of Bed Stage for Patient Compartment of Ambulance Using MR Damper)

  • 최승복;채희동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.26-27
    • /
    • 2014
  • This paper proposes a new bed stage system for vibration attenuation in patient compartment of ambulance. The bed stage which consist of four MR dampers can isolate vibration in the vertical, rolling and pitching directions. After evaluating dynamic characteristics of MR damper, 1/4 bed stage model is formulated. The sky hook controller is then utilized for vibration control. Finally, control responses of the bed stage equipped with MR dampers are presented.

  • PDF