• 제목/요약/키워드: vertical dampers

검색결과 65건 처리시간 0.022초

Multiple tuned mass dampers for controlling coupled buffeting and flutter of long-span bridges

  • Lin, Yuh-Yi;Cheng, Chii-Ming;Lee, Chung-Hau
    • Wind and Structures
    • /
    • 제2권4호
    • /
    • pp.267-284
    • /
    • 1999
  • Multiple tuned mass dampers are proposed to suppress the vertical and torsional buffeting and to increase the aerodynamic stability of long-span bridges. Each damper has vertical and torsional frequencies, which are tuned to the corresponding frequencies of the structural modes to suppress the resonant effects. These proposed dampers maintain the advantage of traditional multiple mass dampers, but have the added capability of simultaneously controlling vertical and torsional buffeting responses. The aerodynamic coupling is incorporated into the formulations, allowing this model to effectively increase the critical speed of a bridge for either single-degree-of-freedom flutter or coupled flutter. The reduction of dynamic response and the increase of the critical speed through the attachment of the proposed dampers to the bridge are also discussed. Through a parametric analysis, the characteristics of the multiple tuned mass dampers are studied and the design parameters - including mass, damping, frequency bandwidth, and total number of dampers - are proposed. The results indicate that the proposed dampers effectively suppress the vertical and the torsional buffeting and increase the structural stability. Moreover, these tuned mass dampers, designed within the recommended parameters, are not only more effective but also more robust than a single TMD against wind-induced vibration.

Design of MR dampers to prevent progressive collapse of moment frames

  • Kim, Jinkoo;Lee, Seungjun;Min, Kyung-Won
    • Structural Engineering and Mechanics
    • /
    • 제52권2호
    • /
    • pp.291-306
    • /
    • 2014
  • In this paper the progressive collapse resisting capacity of steel moment frames with MR dampers is evaluated, and a preliminary design procedure for the dampers to prevent progressive collapse is suggested. Parametric studies are carried out using a beam-column subassemblage with varying natural period, yield strength, and damper force. Then the progressive collapse potentials of 15-story steel moment frames installed with MR dampers are evaluated by nonlinear dynamic analysis. The analysis results of the model structures showed that the MR dampers are effective in preventing progressive collapse of framed structures subjected to sudden loss of a first story column. The effectiveness is more noticeable in the structure with larger vertical deflection subjected to larger inelastic deformation. The maximum responses of the structure installed with the MR dampers designed to meet a given target dynamic response factor generally coincided well with the target value on the conservative side.

DTMD를 이용한 플랜트 수직 펌프의 진동저감 (Vibration Reduction of Vertical Pumps in Industrial Plants Using Double TMDs)

  • 문영종;최현훈;김현수
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.51-58
    • /
    • 2017
  • The characteristics and effectiveness of double tuned mass dampers (DTMD) have been studied by many researchers. DTMD usually consists of one larger mass block and one smaller mass block. In this study, DTMD was proposed to reduce the vibration of vertical pumps in industrial plants. In order to assess the efficiency of the proposed method, numerical analysis for the simplified vertical pump model with single and double TMDs was carried out. It was also investigated that the effects of optimal TMD parameters such as frequency ratio and damping ratio on dynamic responses of the main structure. According to analysis results, DTMD are more effective to control the vibration of the vertical pump and show good robustness to the change in the stiffness of TMD.

Tuned mass dampers for human-induced vibration control of the Expo Culture Centre at the World Expo 2010 in Shanghai, China

  • Lu, Xilin;Ding, Kun;Shi, Weixing;Weng, Dagen
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.607-621
    • /
    • 2012
  • The Expo Culture Centre is one of the permanent buildings at the World Expo 2010 in Shanghai, China. The main structure has an oval shape and consists of 36 radial cantilever steel trusses with different lengths and inner frames made of concrete-filled rectangular steel tube members. Tuned mass dampers are used to reduce the excessive vibrations of the sixth floor that are caused by human-induced resonance. A three-dimensional analytical model of the system is developed, and its main characteristics are established. A series of field tests are performed on the structure, and the test results show that the vertical vibration frequencies of most structural cantilevers are between 2.5 Hz and 3.5 Hz, which falls in the range of human-induced vibration. Twelve pairs of tuned mass dampers weighing 115 tons total were installed in the structure to suppress the vibration response of the system. These mass dampers were tuned to the vertical vibration frequency of the structure, which had the highest possibility of excitation. Test data obtained after the installation of the tuned mass dampers are used to evaluate their effectiveness for the reduction of the vibration acceleration. An analytical model of the structure is calibrated according to the measured dynamic characteristics. An analysis of the modified model is performed and the results show that when people walk normally, the structural vibration was low and the tuned mass dampers have no effect, but when people run at the structural vibration frequency, the tuned mass dampers can reduce the floor vibration acceleration by approximately 15%.

유동유체에 의한 파이프의 동적안정성에 미치는 외부감쇠와 말단질량의 영향 (Effect of External Damping and Tip Mass on Dynamic Stability of Pipes Conveying Fluid)

  • 김효준;류봉조;정승호
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.569-574
    • /
    • 2009
  • The paper presents the influences of the external damping and the tip mass on dynamic stability of a vertical cantilevered pipe conveying fluid. In general, real pipe systems may have some valves and attached mechanical parts, which can be regarded as attached lumped masses and support-dampers. The support-dampers can be assumed as viscous dampers. The equations of motion are derived by energy expressions using extended Hamilton's principle, and some numerical results using Galerkin's method are presented. Critical flow velocities and stability maps of the pipe with external dampers and tip mass are obtained for various tip mass ratios, external damping coefficients and positions of the viscous dampers.

유동유체에 의한 파이프의 동적안정성에 미치는 외부감쇠와 말단질량의 영향 (Effect of External Damping and Tip Mass on Dynamic Stability of Pipes Conveying Fluid)

  • 류봉조;정승호;신광복;한현희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.465-468
    • /
    • 2005
  • The paper deals with the influences of external damping and tip mass on dynamic stability of a vertical cantilevered pipe conveying fluid. In general, real pipe systems may have some valves and attached parts, which can be regarded as attached lumped masses and support-dampers. The support-dampers can be assumed as viscous dampers. The equations of motion are derived by energy expressions using extended Hamilton's principle, and some numerical results using Galerkin's method are presented. Critical flow velocities and stability maps of the pipe with external dampers and tip mass are obtained for various tip mass ratios, external damping coefficients and positions of the viscous dampers.

  • PDF

인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과 (Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers)

  • 정희산;민경원
    • 한국전산구조공학회논문집
    • /
    • 제22권1호
    • /
    • pp.105-115
    • /
    • 2009
  • 휨거동을 하는 전단벽을 대상으로 동일한 총 단면적을 갖는 1개의 전단벽과 마찰형 감쇠기로 연결된 전단벽의 내진성능을 수치해석을 통해 비교하였다. KBC 2005 설계스펙트럼을 근거로 축소 조절한 7개의 지진파를 입력하중으로 마찰형 감쇠기가 설치된 전단벽의 평균응답을 분석하였다. 마찰형 감쇠기의 중요한 설계변수인 기준 마찰력인 슬립하중은 각층의 마찰형 감쇠기 위치에 생기는 수직방향 전단력의 총합의 5, 10, 20, 30, 60, 90%값으로 하여 슬립이 특정한 층에 편중되지 않도록 하였다. SeismoSturct 프로그램을 이용해 비선형시간이력 해석을 수행하여 밑면 전단력, 에너지 소산량, 1층 벽체곡률, 최상층변위 측면에서 마찰 감쇠기의 제진성능을 분석하였다. 기준마찰력의 30%이하 수준의 총 마찰력을 갖는 마찰 감쇠기가 우수한 제진성능을 보였다.

점성감쇠기가 설치된 모멘트골조의 연쇄붕괴 저항성능 (Progressive Collapse Resisting Capacity of Moment Frames with Viscous Dampers)

  • 김진구;이승준;최현훈
    • 한국전산구조공학회논문집
    • /
    • 제23권5호
    • /
    • pp.517-524
    • /
    • 2010
  • 본 논문에서는 비선형 동적해석방법을 이용하여 점성감쇠기가 설치된 철골조 건물의 연쇄붕괴 저항성능을 평가하였다. 감쇠기가 설치된 2경간 보-기둥 부분골조를 이용하여 주기 및 항복강도의 변화에 따른 감쇠력의 효과를 검토하였다. 해석 결과에 따르면 감쇠비가 증가할수록 기둥이 제거된 지점의 수직변위가 감소하는 것으로 나타났으며, 탄성시스템 뿐만 아니라 비탄성시스템에서도 효과가 있는 것으로 나타났다. 감쇠기가 설치된 15층 3경간 철골 모멘트골조의 비탄성해석을 통하여 감쇠기의 효과를 검증한 결과, 기둥이 제거될 경우 처짐이 작게 발생하는 6m 경간 모델보다 처짐이 크게 발생하는 9m경간 모델의 경우에 감쇠기의 효과가 더욱 크게 나타났다.

Performance-based Design of 300 m Vertical City "ABENO HARUKAS"

  • Hirakawa, Kiyoaki;Saburi, Kazuhiro;Kushima, Souichirou;Kojima, Kazutaka
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.35-48
    • /
    • 2014
  • In designing a 300 meter high skyscraper expected to be the tallest building in Japan, an earthquake-ridden country, we launched on the full-scale performance based design to ensure redundancy and establish new specifications using below new techniques. The following new techniques are applied because the existing techniques/materials are not enough to meet the established design criteria for the large-scale, irregularly-shaped building, and earth-conscious material saving and construction streamlining for reconstructing a station building are also required: ${\bullet}$ High strength materials: Concrete filled steel tube ("CFT") columns made of high-strength concrete and steels; ${\bullet}$ New joint system: Combination of outer diaphragm and aluminium spray jointing; ${\bullet}$ Various dampers including corrugated steel-plate walls, rotational friction dampers, oil dampers, and inverted-pendulum adaptive tuned mass damper (ATMD): Installed as appropriate; and ${\bullet}$ Foundation system: Piled raft foundation, soil cement earth-retaining wall construction, and beer bottle shaped high-strength CFT piles.

진동 및 고체음 제어를 위한 스프링 매스댐퍼계의 효과 (The Efficiency of a Spring Mass Dampers System for the Control of Vibrations and Structure-borne Noise)

  • 손충열;구민세;인치만;최순근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 춘계학술대회논문집; 한국과학연구소, 21 May 1993
    • /
    • pp.147-147
    • /
    • 1993
  • All types of dynamic excitation, periodical, pulse or transient in vertical, horizontal or all three directions can be effectively reduced by vibration isolation systems. Typical elements for vibration isolation control are spring units consisting of a group of helical compression springs. In all cases of shock, transient or random excitation energy absorbing dampers have to be added to the spring units in order to reduce system response in the frequency range near the natural frequency of the isolation system. The same isolation system of spring units and viscos-dampers has been used since 1979 for passive protection of buildings and structures has been proved to by very advantageous for vibration and structure borne noise control. Not only because of high vertical flexibility of the spring units, compared for example with typical rubber or neoprene mounts out also because of the horizontal of flexibility, which can be adapted by modifying the spring dimensions to nearly every requirement. It is just normal to use the same basic elements for passive isolation as for active isolation.

  • PDF