• 제목/요약/키워드: vertical acceleration

검색결과 476건 처리시간 0.021초

Numerical verification of a dual system's seismic response

  • Phocas, Marios C.;Sophocleous, Tonia
    • Earthquakes and Structures
    • /
    • 제3권5호
    • /
    • pp.749-766
    • /
    • 2012
  • Structural control through integration of passive damping devices within the building structure has been increasingly implemented internationally in the last years and has proven to be a most promising strategy for earthquake safety. In the present paper an alternative configuration of an innovative energy dissipation mechanism that consists of slender tension only bracing members with closed loop and a hysteretic damper is investigated in its dynamic behavior. The implementation of the adaptable dual control system, ADCS, in frame structures enables a dual function of the component members, leading to two practically uncoupled systems, i.e., the primary frame, responsible for the normal vertical and horizontal forces and the closed bracing-damper mechanism, for the earthquake forces and the necessary energy dissipation. Three representative international earthquake motions of differing frequency contents, duration and peak ground acceleration have been considered for the numerical verification of the effectiveness and properties of the SDOF systems with the proposed ADCS-configuration. The control mechanism may result in significant energy dissipation, when the geometrical and mechanical properties, i.e., stiffness and yield force of the integrated damper, are predefined. An optimum damper ratio, DR, defined as the ratio of the stiffness to the yield force of the hysteretic damper, is proposed to be used along with the stiffness factor of the damper's- to the primary frame's stiffness, in order for the control mechanism to achieve high energy dissipation and at the same time to prevent any increase of the system's maximum base shear and relative displacements. The results are summarized in a preliminary design methodology for ADCS.

Seismic vulnerability assessment of low-rise irregular reinforced concrete structures using cumulative damage index

  • Shojaei, Fahimeh;Behnam, Behrouz
    • Advances in concrete construction
    • /
    • 제5권4호
    • /
    • pp.407-422
    • /
    • 2017
  • Evaluating seismic performance of urban structures for future earthquakes is one of the key prerequisites of rehabilitation programs. Irregular structures, as a specific case, are more susceptible to sustain earthquake damage than regular structures. The study here is to identify damage states of vertically irregular structures using the well-recognized Park-Ang damage index. For doing this, a regular 3-story reinforced concrete (RC) structure is first designed based on ACI-318 code, and a peak ground acceleration (PGA) of 0.3 g. Some known vertical irregularities such as setback, short column and soft story are then applied to the regular structure. All the four structures are subjected to seven different earthquakes accelerations and different amplitudes which are then analyzed using nonlinear dynamic procedure. The damage indices of the structures are then accounted for using the pointed out damage index. The results show that the structure with soft story irregularity sustains more damage in all the earthquake records than the other structures. The least damage belongs the regular structure showing that different earthquake with different accelerations and amplitudes have no significant effect on the regular structures.

유전자 알고리즘을 이용한 SUSPENSION SEAT SYSTEM의 진동 승차감 최적화 (Vibration Ride Quality Optimization of a Suspension Seat System Using Genetic Algorithm)

  • 박선균;최영휴;최헌오;배병태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.584-589
    • /
    • 2001
  • This paper presents the dynamic parameter design optimization of a suspension seat system using the genetic algorithm. At first, an equivalent 1-D.O.F. mass-spring-damper model of a suspension seat system was constructed for the purpose of its vibration analysis. Vertical vibration response and transmissibility of the equivalent model due to base excitations, which are defined in the ISO's seat vibration test codes, were computed. Furthermore, seat vibration test, that is ISO's damping test, was carried out in order to investigate the validity of the equivalent suspension seat model. Both analytical and experimental results showed good agreement each other. For the design optimization, the acceleration transmissibility of the suspension seat model was adopted as an object function. A simple genetic algorithm was used to search the optimum values of the design variables, suspension stiffness and damping coefficient. Finally, vibration ride performance test results showed that the optimum suspension parameters gives the lowest vibration transmissibility. Accordingly the genetic algorithm and the equivalent suspension seat modelling can be successfully adopted in the vibration ride quality optimization of a suspension seat system.

  • PDF

수직축 풍차의 자기동 성능 개선 (Improving the Self-starting Performance of a VAWT)

  • 정선환;최성대;손재율;맥이사 알렉산더;김신호;최명수
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.13-20
    • /
    • 2006
  • The inherent problem of a Darrieus wind turbine is its inability to self-start. Usually, a motor is used to provide angular acceleration until lift forces are produced in the airfoil blades or up until the turbine can already sustain its speed on its own. This paper describes a method of improving the self-starting of an H-type Darrieus vertical axis wind turbine (VAWT) by incorporating a helical Savonius turbine thus utilizing a drag-lift combination. The effect of each turbine in the combination relative to each other is investigated by testing a prototype windmill consisting of three NACA 0015 airfoil blades combined with a Savonius rotor with a helix angle of 180 degrees and whose swept area equals 30% of the entire turbine.

  • PDF

IPPT, SQT에서의 엔진부 비상정지 시스템 설계 및 운용 (Design and Application of Emergency Blockage System for Engine Part at IPPT and SQT)

  • 하성업;이중엽;정태규;한상엽
    • 한국추진공학회지
    • /
    • 제7권2호
    • /
    • pp.44-53
    • /
    • 2003
  • KSR-III의 추진시스템 종합성능시험과 단인증시험을 위한 수직형 연소시험시설이 구축되었다. 이러한 시험은 발사체에 준하는 단품을 사용하는 시험으로, 상대적으로 낮은 수준의 안전율 하에서 시험이 진행되게 된다. 이에 연소시험 안전대책의 하나로 엔진부에 대한 비상정지 시스템이 검토되었으며, 정확하고 빠른 판단을 위하여 연소실 압력과 가속도신호를 사용하는 비상정지 시스템이 구축되었다. 이러한 측정변수를 통하여 점화지연 및 실패, 소화, 추진제 공급상태, 불안정 연소, 구조물 과도진동 등을 감시할 수 있었으며, 이상 상황인지 후 빠르게 시험을 중단할 수 있었다. 이처럼 빠른 판단과 후속조치로 시험의 안전을 확보할 수 있었으며, 목적한 개발시험을 안전하게 마칠 수 있었다.

한국고속철도 천안역사에 대한 소음 및 진동영향 연구 (Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea)

  • 권영철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

라이즈-스팬비에 따른 면진 아치구조물의 지진응답 분석 (The Seismic Response According to Rise-Span Ratio of the Arch Structure With Seismic Isolation)

  • 김수근;김유성;김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2018
  • In order to reduce the seismic response of the spatial structure, a seismic isolation system with sufficient flexibility is used. The natural period of structure with seismic isolation system got be long to avoid prominent period. In this study, The seismic response of the truss-arch structure, which is modeled in three types according to the rise-span ratio is analyzed on El-centro, Northridge and Artificial Earthquake and compared with the seismic response of the truss-arch structure with lead rubber bearing(LRB). When seismic load is applied to the truss arch with isolation system, the horizontal acceleration response of the truss arch is reduced and vertical seismic response is also reduced. The application of the seismic isolation system is effective in controlling the seismic response.

파이프 트러스교의 동적특성 분석을 위한 바이모달트램 주행실험연구 (A Speed Increasing Test of BIMODALTRAM for Dynamic Response Analysis of Pipe-truss Bridges)

  • 김희주;전명일;조은상;황원섭
    • 한국철도학회논문집
    • /
    • 제14권2호
    • /
    • pp.137-142
    • /
    • 2011
  • 바이모달트램(Bimodal tram)은 현행 교통체계를 해소하고자 도입되는 신형식 차량으로 버스와 지하철의 장점을 지니고 있는 시스템이다. 이러한 차량의 도입으로 인해 전용선로인 파이프트러스교가 건설 되어지는데 기존에 시공되지 않은 새로운 형식의 교량으로 이에 대한 동적응답 특성에 대한 분석이 필요하다. 본 연구에서는 바이모달트램의 전용선로인 파이프 트러스교에 대하여 교량 하부에 센서를 부착하여 차량의 주행실험을 실시하였다. 또한, 실험을 통하여 신형식 교량에 대한 변위 및 최대 수직 수평가속도를 계측하여 동적응답 특성을 분석하였다. 이러한 실험결과를 바탕으로 수치해석을 실시하여 증속주행에 대한 거동을 예측하였다.

저손실 자기부상 시스템 개발 (Development of Low Loss Magnetic Levitation System)

  • 김종문;강도현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.592-600
    • /
    • 2005
  • In this paper, a low loss magnetic levitation(Maglev) system is suggested and tested. The suggested Maglev system includes four hybrid magnets which consist of permanent magnet and coil. In the steady state, the levitated module system can be supported by attraction force generated by permanent magnet. The coil current controls only dynamic loads due to external disturbances. The module systems are designed by using finite element method(FEM) software tools such as MAXWELL and ANSYS. Also, digital control systems are designed to keep the magnet airgap at a constant value. The control systems include a VME(versa module europa)-based CPU(central processing unit) board, AD(analog to digital) board, PWM(pulse width modulation) board, 4-quadrant chopper, and sensors. In order to estimate the vertical velocity of the magnet, we use second order state observer with acceleration and gap signals as input and output signals, respectively. The characteristics of the suggested low loss Maglev system are demonstrated by experimental results showing coil current of 0A in the steady state of 3m airgap and performance specifications are satisfied for reference gap and force disturbance.

A study on the liquefaction risk in seismic design of foundations

  • Ardeshiri-Lajimi, Saeid;Yazdani, Mahmoud;Assadi-Langroudi, Arya
    • Geomechanics and Engineering
    • /
    • 제11권6호
    • /
    • pp.805-820
    • /
    • 2016
  • A fully coupled non-linear effective stress response finite difference (FD) model is built to survey the counter-intuitive recent findings on the reliance of pore water pressure ratio on foundation contact pressure. Two alternative design scenarios for a benchmark problem are explored and contrasted in the light of construction emission rates using the EFFC-DFI methodology. A strain-hardening effective stress plasticity model is adopted to simulate the dynamic loading. A combination of input motions, contact pressure, initial vertical total pressure and distance to foundation centreline are employed, as model variables, to further investigate the control of permanent and variable actions on the residual pore pressure ratio. The model is verified against the Ghosh and Madabhushi high acceleration field test database. The outputs of this work are aimed to improve the current computer-aided seismic foundation design that relies on ground's packing state and consistency. The results confirm that on seismic excitation of shallow foundations, the likelihood of effective stress loss is greater in deeper depths and across free field. For the benchmark problem, adopting a shallow foundation system instead of piled foundation benefitted in a 75% less emission rate, a marked proportion of which is owed to reduced materials and haulage carbon cost.