• Title/Summary/Keyword: vernier

Search Result 114, Processing Time 0.021 seconds

The Measurement of Normal Talus in Korean Cadaver (한국인 사체에서의 정상 거골의 실측)

  • Ha, Dong-Jun;Gwak, Heui-Chul;Kim, Jeon-Gyo;Kim, Jung-Han;Lee, Chang-Rak;Kim, Young-Jun;Lee, Jeong-Han;Ha, Byung-Ho;Kim, Ui-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.163-169
    • /
    • 2016
  • Purpose: To investigate the measured values of the talus in Koreans. Materials and Methods: We measured 88 tali from 44 cadavers that have been donated between December 2012 and December 2015. Of the cadavers, 27 were male and 17 were female. Their mean age was 73 years. The length and width of the talus were measured using a digital goniometer and vernier caliper. Results: The values of cadaveric measurement, mean maximal width and length, width and length of the dome anterior, width and length of the posterior facet, height and length of the trochlear medial facet, and height and length of the trochlear lateral facet were $43.6{\pm}2.6mm$, $56.5{\pm}3.3mm$, $32.5{\pm}2.0mm$, $42.2{\pm}2.7mm$, $22.2{\pm}2.2mm$, $34.7{\pm}2.0mm$, $15.3{\pm}1.3mm$, $33.3{\pm}2.9mm$, $25.3{\pm}3.3mm$, and $30.8{\pm}2.4mm$ for men and $38.9{\pm}1.6mm$, $53.6{\pm}2.4mm$, $27.9{\pm}2.1mm$, $37.4{\pm}3.2mm$, $20.6{\pm}0.8mm$, $31.9{\pm}1.2mm$, $13.6{\pm}2.6mm$, $28.4{\pm}2.5mm$, $24.9{\pm}2.1mm$, and $28.9{\pm}1.4mm$ for women, respectively. The size of the talus showed an accuracy of 86% when anteroposterior diameter was greater than 59 mm. A difference in the size of the right and left talus was not observed. The mean inclination and declination angles were $24.4^{\circ}{\pm}4.2^{\circ}$ and $28.2^{\circ}{\pm}5.4^{\circ}$ for men, and $24.6^{\circ}{\pm}3.6^{\circ}$ and $24.7^{\circ}{\pm}6.7^{\circ}$ for women (p=0.980, p=0.018), respectively, at least $15^{\circ}$, which showed a big difference for every object up to $37^{\circ}$. Conclusion: This paper, to the best of our knowledge, is the first study to measure the talus in Koreans. There were differences by gender and ethnicity in the in measured talus values. The measurements were smaller than European-Americans and greater than Japanese.

The Tooth Size RelaTionship Between Crowding Patients and Normal Subjects in Korean (총생치열을 갖는 교정환자와 정상인의 치아크기 비교)

  • Han, Man-Deuk;Jeon, Eun-Sook
    • Journal of dental hygiene science
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • This study was undertaken to compare the tooth and arch size between crowding patient and normal subjects. Two group of dental casts were selected on the basis of crowding patients and normal subjects. One group, consisting of 40 pair of dental casts(20 male and 20 female), exhibited noncrowded dentitions. A second group, consisting of 40 pairs of dental cast(21 male and 21 female), exhibited remarkably crowding need for orthodontic treatment. Tooth width measurements were made with a sliding digital caliper with Vernier scale neared 0.01 mm. Mean, standard deviation, T-test of the following parameters were used to compare two group : individual mesiodistal crown widths, arch width and arch length. The following result were obtained. In the mesiodistal crown widths, normal subjects had generalized larger teeth than Wheeler's results(human tooth size index), except for maxillary central incisor, maxillary 2nd premolar, mandibular canine, and mandibular 1st molar. In the orthodontic patients with crowded dentitions, the mesiodistal tooth crown widths were generalized larger teeth than noncrowded normal subjects. In the arch width and arch length, the crowded dentition group had smaller arch width and arch length than the normal group.

  • PDF

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Measurement of Verticality and Joint Gaps of a Near-surface Disposal Facility Vault Through a Mock-up Test for Fill-up Stages (표층처분시설 처분고의 목업테스트를 통한 채움단계별 수직도 및 이음부 벌어짐 측정)

  • Choi, Dong-Ho;Ann, Ki-Yong;Choi, In-Yong;Lee, Hyuk-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.537-544
    • /
    • 2021
  • In order to describe the fill-up stages of a near-surface disposal facility vault, a mock-up test is performed, and its behavior during the fil l -up stages is investigated. On an in-site concrete foundation with a l ength of 6600mm, a width of 6600mm and a thickness of 400mm, a reinforced concrete disposal vaul t is manufactured with 4 precast (PC) corner wal l s and 8 PC side wal l s. 36 wasted drums are pl aced on the 1st fl oor in 6 by 6, and then the empty space is fil l ed with grout fil l er. These processes are repeated up to the 5th floor, and the verticality and the joint gaps are measured for each fill-up stage. The verticality is measured using a level at 6 positions on each side wall (3 positions on the left and right sides, respectivel y), i.e. a total of 24 positions on the 4 side wal l s. The joint gaps are measured at 9 positions on each side wal l (3 positions on the left, center and right sides, respectively), I.e. a total 36 positions on the 4 side walls. To measure the joint gaps, crack tips are installed on the left and right sides of every joint gap, and vernier calipers are used. The measured verticality obtained through the mock-up test was found to be ±0.1° based on the initial stage (ST0), and the result of the joint gap was up to 0.38mm. This appears to have a negligible effect on the structure.