• Title/Summary/Keyword: ventilation house

Search Result 303, Processing Time 0.02 seconds

A Study on Ecological Characteristics of Interior Design for Apartment Building - A Case Analysis of Model Houses for Medium- and large-sized Pyeong Apartments in Busan Area - (아파트 실내디자인의 생태적 특성에 관한 연구 - 부산지역 중.대형 평수 아파트 모델하우스 사례분석 -)

  • Shin, Jae-Moon;Youn, Ji-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.181-191
    • /
    • 2007
  • This study attempted to analyze the characteristics of interior design of the apartment units of Model-houses in terms of ecological aspects. 9 companies that possessed their model houses among the construction companies in Busan area as of August 2006 were selected. 20 units in the model houses of these companies were visited and analyzed. Through literature review, the guideline for the environmentally-friendly residential design was designed and developed to the checklists. The data collected were analyzed to find out the ecological characteristics of the interior space of apartment units. The findings are the followings. First, energy efficiency was properly considered in terms of natural lighting and natural ventilation. Second, in sustainability, the materials for floors and walls could not be reused even though they were environmentally-friendly. Water system needs more improvement for sustainable development including grey-water and rain recycling system. Third, interior greening should be applied more for better environment both physically and emotionally. It is expected that future housing will be more high-risen and densely-populated apartment spaces. Therefore, an approach to new ecological aspects including an emphasis on interior greening, use of eco-materials and adhesives, water recycling and flexibility of the spatial configuration should be made for the next generation.

Aerodynamic Approaches for Estimation of Waste Disease Spread in Pig Farm through Airborne Contaminants (양돈장의 소모성질병 확산 분석을 위한 현장 모니터링 및 공기유동학적 분석)

  • Seo, Il-Hwan;Lee, In-Bok;Moon, Oun-Kyung;Kwon, Kyeong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • Pig chronic wasting disease, including porcine reproductive and respiratory syndrome (PRRS) and postweaning multisystemic wasting syndrome (PMWS), have made a continuous economic damage in pig farms. Airborne spread of livestock viruses are an important spread factor which is difficult to analyze due to invisible airflow and limitation of measurement. The objective of this study is to analyze airborne disease spread between buildings in the experimental pig farm by means of field experiment and computational fluid dynamics (CFD). The field experiments were conducted to capture airborne virus using air sampler and teflon filter along multi points in the experimental pig farm. The samples were tested in terms of virus detection resulting in positive reaction for PRRS and PCV-2 viruses, which can be a firm evidence of airborne virus spread. The CFD simulation model was developed by considering complex topography, wind conditions, building arrangement, and ventilation systems and was used to analyze airborne virus spread according to different wind conditions. The CFD computed result showed a possibility of airborne virus spread via livestock aerosol from infected pig house to neighboring pig houses according to wind directions. The CFD simulation technique is expected to provide significant data for estimating and making a counterplan against airborne disease spread.

Resident's Subjective Responses to Indoor Air quality of Multi Family Houses in Winter (공동주택의 겨울철 실내공기환경에 대한 거주자 반응)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.173-186
    • /
    • 1997
  • The purpose of this study is to find out understand the resident's subjective responses to physical indoor environment. The questionnaire survey was carried out to measure form Jan. 8th to Feb. 2th in 1996, the typical external climate of winter in Korea. The subjects were four hundred and eleven housewives, living in apartments of RC structure I Ilsan apartment complex. As the result, residents usual ventilate once or twice a day by opening outward windows for about ten minutes. Unpleasant smell producted by cooking and wet garbage made most of them negatively respond to kitchen's air quality. regression analysis of relativeness between sense of air freshness smell, dust and comfort revealed that sense of comfort was the most highly related with the extent of bad smell. Housing factors such as size of apartments and ventilating, smoking and gas usage had significant effects on indoor air quality and the subjective responses in winter. Therefore it is especially important to consider air pollution problem from the beginning stage when planning small apartments. It is required that the government of environment has to emphasize the importance of ventilation to residents, and makes an effort to establish the design criteria on indoor air quality in house.

  • PDF

Effect of Carbonization Temperature on Hygric Performance of Carbonized Fiberboards

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.615-623
    • /
    • 2014
  • Increases of public attention on healthy environment lead to the regulation of indoor air quality such as Clean Healthy House Construction Standard. This standard covers emission of total volatile organic compounds (TVOCs) (e.g., formaldehyde, benzene, and toluene), ventilation, and use of environmentally-friendly products or functional products. Moisture absorption and desorption abilities are a recommended functionality for improving indoor air quality. In this study, moisture absorption and desorption capacities of carbonized board from wood-based panels and other materials were determined by using UNT-HEAT-01 according to ISO 24358:2008. Pine had higher moisture absorption and desorption capacities ($49.0g/m^2$ and $35.3g/m^2$, respectively) than hinoki cypress, cement board, gypsum board, oriented strand board, and medium density fiberboard (MDF). The moisture absorption and desorption capacities differed considerably according to the wood species. After carbonization process at $400^{\circ}C$, the absorption and desorption ability of MDF increased to 38% and 60%, respectively. However, moisture absorption and desorption capacities decreased with increasing carbonization temperature, but they were still higher than original MDF. Therefore, it is suggested that carbonization below $600^{\circ}C$ can improve moisture absorption/desorption capacities.

A Study on the Residential Character and Consciousness of Housing Environment in Earth Housing (흙주거의 거주특성과 주거환경 의식에 관한 연구)

  • Jeong Joo-Seong;Kim Jeong-Gyu;Oh Yang-Ki
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.47-54
    • /
    • 2006
  • The purpose of this study is to investigate residential characters and consciousness about housing environment concerned with earth housing, and to suggest basic data reflectible on the planning of earth housing. Residential characters and consciousness are investigated with the people lived in forty seven earth housings located in nationwide scale through interviews and questionnaire. As a result, it is shown that a reason of health like sick house syndrome, residential environments such as ventilation and lighting, site environment such as neighbor and greenfield are very influential elements to the consciousness of inhabitants. Meanwhile, approximation of residential area, the connection with public facilities including medical service, educational and commercial conditions, additionally, preparation of disaster and crime prevention in a viewpoint of safety are pointed out as relatively weak ones. It means that earth housing is not systematically fixed as a residential site because it is personally progressed by small number of peoples having different reasons. For the improvement of systematic housing environment, development and proposition of various model are needed on earth housing and its site.

Greenhouse Cooling by Fog System (FOG SYSTEM 을 이용한 여름철 온실냉방)

  • 서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

Study on Indoor Thermal Environment Controlled by Portable Cooler (실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토)

  • Choi, Dong-Kyun;Song, Doosam;Kim, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

A Survey on Housing Environment of Vulnerable Population - Focused on the Recipients of Visiting Health Care Services - (취약계층의 주거환경 실태조사 -보건소 방문보건사업 대상을 중심으로-)

  • Kim, Hee Gerl;Nam, Hye Kyung
    • Journal of Korean Public Health Nursing
    • /
    • v.29 no.3
    • /
    • pp.528-539
    • /
    • 2015
  • Purpose: The aim of this study is to provide baseline data on the housing environment of a vulnerable population. Methods: This study provides a descriptive survey on the housing environment of a vulnerable population of a city in Gyeong-gi province. A total of 9,061 households were selected as research participants. Data were collected through face-to-face interviews by visiting nurses from February 2014 to March 2014. Results: Interviewees answered "poor" on items including cold drafts, illumination, daylight penetration, inflow of polluted air, house odor, stairs safety, noise, mold, pests, and ventilation. The score for housing environment problems showed a significant group difference due to gender, age, economic status, family type, type of housing, and type of ownership. Conclusion: These results indicate that the vulnerable population is exposed to a poor housing environment. Thus, there is an urgent need to improve the housing environment for the vulnerable population. Based on this study, linking a visiting health care service program and housing environment improvement projects from relevant administrative agencies might be recommended in order to effectively improve the housing environment.

Indoor, Outdoor, and Personal Exposure to Nitrogen Dioxide Comparing Industrial Complex Area with Country Area (공단지역과 시골지역 주택 실내, 실외 및 개인의 이산화질소 노출평가)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.183-187
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay, and outdoor levels. Various indoor and out-door combustion sources produce nitrogen dioxide ($NO_2$), which is a by-product of high temperature fossil fuel combustion. Especially, the presence of gas ranges and smoking have been identified as major factors contributing to indoor $NO_2$ exposures. In this study, we compared an industrial complex area with a country area by assessing the personal exposure to $NO_2$with measurements of indoor and outdoor $NO_2$ levels in residences and by house characteristics and questionnaire. Personal exposure concentrations were significantly correlated with indoor $NO_2$ concentrations of residences in both the industrial complex area and the country area with correlation coefficients of 0.561 and 0.664, respectively, compared to outdoors. Multiple regression analysis, indicated that indoor $NO_2$ levels in residences were only affected by outdoor levels (p = 0.000) in spite of higher indoor sources such as smoking. Therefore, it is suggested that outdoor air quality as well as indoor air quality should be considered in the reduction of the personal exposure to air pollutants.

Study on Development of Subroutine based on TRNSYS for Unglazed Transpired Air Collector System (TRNSYS 기반 무창기공형 공기식 집열 시스템 부프로그램 개발에 관한 연구)

  • Park, J.U.;Lee, E.J.;Chung, M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2003
  • UTAC(unglazed transpired air collector) system has unique advantage for space heating and tempering ventilation air over the conventional collector system such as flat plate and vacuum collector. UTAC can improve radiative and convective loss due to nonglazed component and enhanced plate surface configuration. and heating energy and its equivalent green house emission performance can be improved from the use of this like collector in building application. The Option D Calibration simulation approach of IPMVP(International Performance Measurement and Verification Protocol) in ESCO businesses has been recommended to use of the calibrated computer modules like these Energy-10. DOE2.1E and TRNSYS(transient system simulation). This study is to develop subroutine type-203 of TRNSYS15.2 program and appraise thermal performance of UTAC. With newely addeded subroutine type-203. 1) Thermal performance of unglazed transpired collector could be possible based on dimensionless variables such as efficiency and heat exchanger effectiveness. and 2) Assessement of energy consists of solar useful and insulation saving for UTAC could be possible.