• Title/Summary/Keyword: ventilation house

Search Result 303, Processing Time 0.027 seconds

A Study on the Elderly Households' Needs for Housing Modification (노인가구 특성에 따른 주거개조요구에 관한 연구)

  • Lee, Kwang-Soo;Park, Soo-Been
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.278-283
    • /
    • 2009
  • This study aims to figure out the old people's needs for modification of their housing to maintain an independent lifestyle despite their health status and living arrangements. The total of 438 residents take part in the questionnaire survey research through the quota sampling method grouped by age (60-64 group, 65-69 group, 70-74 group, and over 75 group), sex (male and female), and house type (apartment houses and others). The results are as follows. (1) The old people's most inspired modification needs in interior spaces are remodeling the heating controls in the living room and the bedroom, ventilation facilities and storage spaces in the kitchen, non-slip tile flooring and ventilation facilities in bathroom, an easy door-lock, non-slip tile flooring, a draft cut-off, and storage spaces in the entrance. Besides they require emergency alarm, easy door and window locks, fire and gas alarm, and furniture with easy handling. It is necessary to supply the aged with the appropriate heating controls for their sensitivity to heat, with enough storage spaces for the increased possessions, and with diverse safety systems reflected blunting of mobility and sensibility. (2) As they grow older, the aged require more remote controls and safety facilities such as emergency alarm, easy locks and furniture with distinguishable colors. Male elderly is more concerned with safety, while female elderly do with convenience due to their different time spending in the house. The elderly residents in the apartment houses require the heating controls, a draft cut-off, and storage space less than other types of houses. Thus modification of the heating controls, a draft cut-off, and storage space are regards as basic needs for the elderly residents in non-apartment houses.

  • PDF

The Effects of Job Stress on Workers' Physiological Somatic Complaints (직무스트레스가 근로자들의 신체적 불편감에 미치는 영향)

  • Lee, Jong-Eun;Jung, Hye-Sun;Lee, Bok-Im;Kim, Soon-Lae
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.2
    • /
    • pp.289-297
    • /
    • 2004
  • Purpose: This study was conducted to determine factors affecting workers' physiological somatic complain using the Job Stress Model proposed by the National Institute for Occupational Safety and Health (NIOSH). Method: Data were collected from the 1st to the 30th of December 1999. The subjects were 2.123 workers employed at 155 work sites. Collected date were analyzed through SAS/PC program. Result: According to individual characteristics, younger and women groups showed significantly higher physiological somatic complaint than elder men groups. By work condition, groups with higher physiological somatic complaint included workers of irregular shift work. Dark lighting, improper temperature in winter, improper ventilation, inappropriate humidity, unpleasant work environment and crowded work place were significantly related with physiological somatic complaint. By work-related factor, physiological somatic complaint was high in those with higher variance in work load, quantitative work load, role conflict, job burden, role ambiguity and future ambiguity. On the other hand, physiological somatic complaint was low in those with little underutilization of ability. As for the relationships between physiological somatic complaint and non-work related factors, physiological somatic complaint was high in workers who had a side job, were bringing up infants alone, cleaned the house alone, cared for the elderly and disabled persons, were studying, were volunteering at another organization, and were spending 5-10 hours in religious activities per week. Physiological somatic complain was in significantly negative correlations with overall social support, supervisory support and family support, but in significantly positive correlations with co-worker support. Conclusion: The main predictors of physiological somatic complain were gender, shift work pattern, overtime work, ventilation, role ambiguity, role conflict, future ambiguity, job control, variance in work load, overall social support, worker with side job, worker who cleans the house alone, worker who is studying. These predictors explained 19.10% of the total variance of physiological somatic complain.

  • PDF

Study on Moisture Variation in Light Frame Wall with Different Wall Assemblies (I) - Evaluation of Improvement with Laboratory Test - (벽체구성에 따른 목조벽체 내 수분변화에 대한 연구(I) - 실내 실험을 통한 개선 가능성 평가 -)

  • Kim, Se-Jong;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.320-329
    • /
    • 2009
  • The purpose of this study was reducing the moisture accumulation in a wall, which can threaten the structural safety of light-frame wall and make residential environment poor. For the purpose, the laboratory test was carried out with different wall assemblies. Vapor retarder and air gap for ventilation were added to the typical wall. The improved performance of the proposed walls was examined through the test with distinct difference of temperature and relative humidity between outdoor and indoor air conditions. Increased dampproofing performance of additional vapor retarder was effective on reduction of moisture transmission from inside the house into the wall. However, unexpected high relative humidity was shown in the wall with two additional vapor retarder because of excessive dampproofing performance or inadequate location of vapor retarder. And, the open air gap induced the moisture transfer from inside the wall into outdoor air by ventilation. If the alternative to the induction of moisture transmission from inside the house into the wall with open air gap can be found, moisture reduction effect of that will be increased obviously.

Studies on the Method of Reducing of the Photobleaching Leaves and Shortening the Curing Period in Burley Tobacco Stalk Curing (버어리종담배 대말림시 백화엽발생방지 및 건조기간단축에 관한 연구)

  • 김상범;백기현;추홍구
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.2
    • /
    • pp.252-257
    • /
    • 1983
  • This study was conducted to find out the stalk curing methods that can reduce photobleaching, and shorten the curing period in burley to bacco stalk curing. The results obtained summarized as follows. In the ventilation window-plot, the temperature within the curing house was high and the curing period was shortened, too. The rate of photobleached leaves of whole plant stalk curing-plot was higher than those of any other plots. In the ventilation window-plot, the labor of operating the curing house was saved and the yield and visual quality of cured leaves were high, too. For reducing the photobleaching of leaves, following procedures are desirable; to prevent the lower leaves from drying up and overripening at maturing stage, cut the stalk after first or second priming, shorten the curing period as possible when the 80% of leaf bodies changed brown.

  • PDF

Control of Spinach Downy Mildew by Forced Ventilation in Greenhouse Cultivation (강제환기처리에 의한 비닐하우스재배 시금치의 노균병 발생 억제)

  • Park, Seok-Hee;Lee, Joong-Hwan;Woo, Jin-Ha;Choi, Seong-Yong;Park, So-Deuk;Moon, Yong-Sun
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.1
    • /
    • pp.147-154
    • /
    • 2014
  • Spinach downy mildew caused by Peronospora spinaciae is the main reason of yield reduction in Korea as well as in worldwide. After forced ventilation or horizontal air circulation fans were installed to control growth conditions in green house, the changes of temperature, relative humidity (RH), growth and yield, and occurrence of downy mildew were examined. Althought here was no significant difference of temperature between the treatments, RH as 9.2% lower at nighttime by forced ventilation. In addition, final fresh weight was increased to 17.8g compared to control (10.1g), which as 7.7g enhancement. Downy mildew s tarted to show 20 days after sowing (DAS) and increased to 34.7% at 60 DAS on harvest time in control. In contrast downy mildew was occurred 40 DAS with 0.7% incidence rate and 4% at harvest by forced ventilation. The results indicated that reduction of only 9.2% of RH at nighttime by forced ventilation in greenhouse spinach growth was dramatically thrived over 76.2%. Additionally spinach downy mildew occurred 20 days later with extremely lower incident rate, which meant 88.5% reduction of downy mildew.

EFFECTS OF GAS EXHAUSTED FROM GASOLINE ENGINE ON PLANTS GROWN IN THE GREENHOUSE

  • Sugimoto, H.;Yamashita, J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.487-494
    • /
    • 1993
  • In order to establish a fully automatized pest control in the a greenhouse , the authors developed a prototype of microcomputer installed spraying vehicle which traveled along the furrows. Since a power sprayer mounted on the vehicle was driven by gasoline engine, plants grown in the greenhouse might be injured by the gas exhausted from the engine. Thus , effects of exhausted gas on photosynthetic rate and the shedding of flowers and buds of plants were examined. At first, effects of exhausted gas on photosynthetic rate of potted sweet pepper (Capsicum annuum L.) and eggplant(Solanum melongena L.) plants were examined. In a closed vinyl house the engine was operated for 5 minutes and plants were exposed to the gas for 2hours in the daytime on a fine day. Photosynthetic rate did not significantly decreased by the treatment in both species. Secondly, effects of ehtylene on the shedding of flowers and buds of sesame (Sesamum indicum L. ) were examined. In the closed and partiall opened vinyl house, the engine was operated for 5 minutes and potted sesame plants were exposed to the gas for 12 hours in the night. In partially opened vinyl house, ethylene concentration decreased to 0 ppm 3 hours after the engine was stopped and flower and bud did not shed. In contrast, when vinyl house was closed ethylene concentration was 0.75 pm even 12 hours after the engine was stopped and flowers and buds shed markedly and epinasty was observed in upper young leaves. As mentioned above , it was revealed that injury of plants in the greenhouse caused by the gas exhausted from a gasoline engine could be prevented by providing suitable ventilation.

  • PDF

An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control (한지창호의 실내 온.습도 조절효과에 관한 실험적 연구)

  • Jang Gil-Soo;Park Sa-Keun;Song Min-Jeong;Shin Hoon
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.8
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.

Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions (다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구)

  • Lee, Keon-ho;Kim, Hyeon-soo;Jang, Dae-hee;Moon, Soo-young
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.