Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions

다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구

  • 이건호 (한국건설기술연구원, 건축연구부) ;
  • 김현수 (한국건설기술연구원, 건축연구부) ;
  • 장대희 (한국건설기술연구원, 건축연구부) ;
  • 문수영 (한국건설기술연구원, 건축연구부)
  • Published : 2005.06.30

Abstract

Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.

Keywords

References

  1. Daniels K., Technologie des oekologischen Bauens, Birkhaeuser, Berlin, 1999
  2. Lee K., Untersuchung zur Einsatz-moeglichkeit von Doppelfassaden bei hohen Verwaltungsbauten mit Glasfassaden im extremgemaessigten Klimagebiet, Berlin, 2003
  3. Oesterle 외, Doppelschalige Fassaden, Ganzheitliche Planung, Callwey, Muenchen, 1999
  4. 김현수 외, 복합기능 생태적 건물외피 조성 기술 개발 I, II, 한국건설기술연구원, 2003, 2004
  5. 종합진단 보고서, 노후ㆍ불량주택 재건축 진단, 한국건설기술연구원, 2003
  6. www.passiv.de
  7. M. Schulz, Bautechnik, Leben im Schwitzkasten, Der Spiegel 47/2004, http://www.spiegel.de/spiegel/0,1518, 327749,00.html
  8. Boris Kruppa, Untersuchungsergebnisse der Pro- Klima Felduntersuchung, Raumklima in Buerohaeusern, 21. Internationaler Velta Kongress' 99, Tirol, 1999