• Title/Summary/Keyword: ventilation house

Search Result 303, Processing Time 0.067 seconds

Analysis of Ventilation Efficiency by Duct System in Pig House (돈사 덕트 환기시스템의 효율 분석)

  • Song, J.I.;Yoo, Y.H.;Lee, D.S.;Choi, H.C.;Kang, H.S.;Kim, T.I.;Jeon, B.S.;Park, C.H.;Kim, H.H.
    • Journal of Animal Environmental Science
    • /
    • v.8 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • The experiment was carried out to investigate the optimal air velocity for improving the ventilation efficiency of duct ventilation system used in Korean swine building. The results are followed ; In 2.2 m height of duct, the air velocity of hole was 5.0 m/s as the over level of recommendation. In different hole interval, the air velocity was various of 4.6${\sim}$11.6 m/s in narrow hole interval, 5.4${\sim}$10.9 m/s in broad hole interval. But the air velocity was 6.6${\sim}$7.7 m/s in duct system pierced hole with equal interval, and it was equal velocity in different parts of duct in this hole interval.

  • PDF

A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance (공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses (초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가)

  • Kim, Young-Bae;Kim, Jae-Hong;Sung, Jae-Yong;Lee, Myeong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows (초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교)

  • Choi, Tae-Hwoan;Jeon, Mi-Sook;Lee, Jung-Hyun;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF

Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season (하절기 효율적인 하우스 온도 습도 관리에 관한 연구)

  • 우영회;남윤일;송천호;김형준;김동억
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 1994
  • It is necessary to effective temperature and humidity management for normal growth of crops in protected cultivation during the summer season. Because the highest temperature of vinyl house inhibit normal growth of crop and decrease of crop production or marketability in summer season. Finally, the vinyl house was impossible some crop cultivation in summer season. This study was conducted to investigate effective and economic method for temperature drop in protected cultivation during the summer season. 1. In medium size vinyl house(5$\times$13$\times$3m), the effect of temperature drop appeared the highest in treatment of shading with aluminium thermal curtain+fog system+ventilation with fan. The effect of temperature drop was about 1$0^{\circ}C$ lower than outer air temperature and about 4$^{\circ}C$ lower than outer soil temperature. 2. The effect of temperature drop according to shading with aluminium thermal curtain+fog system+ventilation with fan during the highest temperature of summer season Jul., 20 to Aug., 21 was appeared about 8$^{\circ}C$ lower than outdoor above ground(1.2m) and about 7$^{\circ}C$ lower than outdoor surface ground. 3. The changes of solar radiation during a day according to shading with aluminium thermal curtain+ventilation with fan and shading with black curtain+ventilation with fan treatments was appeared respectively about 29.3%, 32.5% of outdoor solar radiation a fine day and respectively about 27.4%, 31.8% of outdoor solar radiation a cloudy day.

  • PDF

Concentrations of VOCs and Formaldehyde in Newly Constructed Apartment Buildings Before and After Residence (신축공동주택의 입주전후 VOCs 및 HCHO 농도)

  • Park, Sang-Eun;Kim, Hyun-Wook;Sim, Sang-Hyo;Lee, Se-Hoon;Koo, Jung-Wan
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.98-103
    • /
    • 2007
  • This study was performed to measure the changed concentrations of formaldehyde and volatile organic compounds after moving in the newly constructed apartment buildings at Seoul. From December 2004 to October 2005, we measured the concentration of formaldehyde and volatile organic compounds in newly constructed apartment buildings before and after residence. In conclusion, it showed that there was a significant relationship association between the con centration of the volatile organic compound and the formaldehyde and remodeling of the house, built in-furniture, and ventilation of the house. Therefore, it was suggested that we need preventive measures and management plans about various factors such. as remodeling, and built in-furniture, ventilation to decrease the concentrations of volatile organic compounds and formaldehyde.

The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory (대학교 신축기숙사의 휘발성유기화합물 농도 및 새집증후군 반응)

  • Choi, Yoon-Jung;Kim, Jung-Jae;Jang, Yoon-Jeong;Oh, Ye-Seul
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.255-260
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor air quality by TVOC concentration and residents' responses and to analyze the influencing factors of IAQ in newly built university dormitory. The field measurements on the levels of TVOC and HCHO were carried out three times at an interval of 4 weeks in 3 rooms of a dormitory. The questionnaire survey on the residents that inquired into the lifestyle, the consciousness related to IAQ, and the responses of SHS was fulfilled. According to the results, the level of TVOC was approximately $0.14{\sim}18.5ppm$ and HCHO was $0.23{\sim}6.89ppm$ during 3 month since construction completion, which are seriously in excess of standard level, and seemed to be on the decrease as time goes by. The factors influencing the differences of the levels of TVOC or HCHO were the amount of ventilation including infiltration, heating temperature, relative humidity, or the use of living things including chemical. However, the residents rarely felt the responses of SHS and did not be conscious of the importance of ventilation.

  • PDF

An Analysis on the Safety related to Architectural Elements in Housing (주거 공간 내 건축 구성 요소의 안전성 분석)

  • Yi, Hoon;Lee, Yong-Hee;Jeong, Sang-Kyu
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this study is to analyze the safety issues with regard to architectural elements in housing. Causes of accidents and threats to health are reviewed for 'safety' aspects. Threats to health tend to draw more attention due to recent increase of SHS and its public perceptions. The majority of victims by accidents in residential houses are on juveniles aged under 14 in bathrooms and living rooms. Non-slip finish materials are recommended to floors for access and circulation and protective pads to furniture edges. Colored glass may increase the safety of the windows in the living room. Handles and non-slip mats will be a good addition for the safety. Human scale design of the kitchen system is mandatory and appropriate size of storages for hazardous equipment are to be provided. Passive air ventilation for better air quality by dwellers in residence is occasionally used whereas large-scale apartments provide mechanical ventilation to supplement the volume of fresh air. Since the internal air quality is proved one of the major causes of atopic and respiratory diseases, steady effort to achive better air quality utilizing appropriate materials, plants and equipment is mandatory. Frequent cleaning and the use of anti-fungus materials are necessary because House Dust Mites are believed to be one of main causes of such diseases.

Energy Saving by Combination of Element Technologies of Zero-Energy House (제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구)

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

The Survey and its Effect for Cooling Systems used in Dairy Cattle Farms in Gyeonggi (경기지역 젖소 농가 고온저감시설 활용 실태조사 및 축사내 온습도 변화)

  • Lee, Jun-Yeob;Choi, Hee-Cheol;Lee, Dong-Hyun;Woo, Saem-Ee;Ki, Kwang-Seok;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • This survey was conducted to give the basic information and temperature and humidity variation by cooling systems in dairy farms in Korea. A total of 36 farms were surveyed in Gyeonggi province with the general information of farms such as milk production, and milk quality, types of cooling systems, and its operation method of dairy farms. All of surveyed farms have cooling fan and some have 1 more cooling systems such as sprinkler, foggy systems, ventilation duct, and shower system. Although the indoor THI of cow house was decreased by either ventilation duct or foggy system during hot season, the range belongs to mild heat stress scale for dairy cows.