• Title/Summary/Keyword: ventilating performance

Search Result 48, Processing Time 0.02 seconds

Design of Optimized Multi-Fuzzy Controllers by Hierarchical Fair Competition-based Genetic Algorithms for Air-Conditioning System (에어컨시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적화된 다중 퍼지제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Kim, Hyun-Ki;Oh, Sung-Kwun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.4
    • /
    • pp.344-351
    • /
    • 2007
  • In this paper, we propose an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of air conditioning system with multi-evaporators. Air conditioning system with multi-evaporators is composed of compressor, condenser, several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as a kinds of controller types such as a simplified fuzzy inference type. Here the scaling factors of each fuzzy controller are efficiently adjusted by Hierarchical Fair Competition-based Genetic Algorithms. The values of performance index of the simulation results of the A company type compare with simulation results of simplified inference type.

A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers- (에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구-)

  • 구형모
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

A Study on Winter Season Usability Performance Improvement of Flapper Valve for KUH-1 (한국형 기동헬기 동계운용능력 향상을 위한 플래퍼밸브 개선연구)

  • Choi, Jae Hyung;Chang, In ki;Shim, Dai Sung;Ahn, Jeong Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Flapper Valve of Korean Utility Helicopter(KUH-1) is an essential equipment in Environmental Control System(ECS) for pilot to perform flight mission. It provides pilots and crews with heating, ventilating and air conditioning. It has function of maintaining room temperature to sustain operational capability for pilot and crew. This paper summarizes pilot comments in flight test which are classified by cause of occurrence and the troubleshooting process about each comment. It also describes design improvements which was derived from troubleshooting and suggests verification results of flight test at low temperature.

Study on Improvement in Cooled Air Defense Gun System Including Closed Drum Basket (비개방형 포탑드럼바스켓을 가진 대공포체계의 냉방장치개선 연구)

  • Hwang, Boo Il;Lee, Dong Hui;Kim, Chi Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.109-113
    • /
    • 2015
  • Combat vehicles need an air-conditioning unit, although new combat systems tend to use an integrated system for heating, cooling, and ventilating. The specifications of an air-conditioning unit depend on the combat vehicle's purpose. It is difficult to send cooling air from the air-conditioning unit to a gun turret through the drum basket because the gun turret rotates and consists of a closed anti-aircraft shell magazine. In this study, we considered an air-conditioning unit for armored combat vehicle based on the special requirements and military specifications. We evaluated the performance of the air-conditioning unit despite the rotating gun turret through analysis and tests in terms of flow improvement compared to the previous model.

Performance Evaluation Study of Solarwall-Photovoltaic Module to Generate Solar Electric Power (SWPV 태양 열-전기 복합생산 모듈 성능평가 연구)

  • Naveed Ahmed T;Kang E. C.;Lee E. J.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.397-402
    • /
    • 2005
  • Photovoltaic (PV) module can generate electricity using sunlight without causing any environmental degradation. Due to higher fossil fuel prices and environmental awareness, PV applications are becoming more popular as clean source of electricity generation. PV output is sensitive to the operating temperature and can be drastically affected in Building Integrated PV (BIPV) systems. PV Solarwall (SWPV) combination and PV systems have been evaluated in this study for improvement in electrical output and system costs. PV modules under forced ventilation. A 75W polycrystalline silicon PV module was fixed on SW in front of the ventilation fan as it was indicated to be the coolest position on the SW in phoenix simulations. The effectiveness of cooling by means of the forced ventilating air stream has been studied experimentally. The results indicate that there appears to be significant difference in temperature as well as electricity output comparing the SWPV and BIPV options. Electrical output power recovered is about $4\%$ during the typical day of the month of February. RETScreen(R) analysis of a 3kW PV system hypothetically located at Taegu has shown that with typical temperature reduction of $15^{{\circ}C$, it is possible to reduce the simple payback periods by one year. The work described in this paper may be viewed as an appraisal of a SWPV system based on its improved electrical and financial performances due to its ability to operate at relatively lower temperatures.

  • PDF

Design of Optimized Multi-Fuzzy Controllers for Air-Conditioning System with Multi-Evaporators (다중 증발기를 갖는 에어컨시스템에 대한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In this paper, we introduce an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of aft conditioning system. Air conditioning system is composed of compressor, condenser several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as two kinds of controller types such as a continuous simplified fuzzy inference type and a discrete fuzzy lookup_table type. Here the scaling factors of each fuzzy controller ate efficiently adjusted by veal coding type Genetic Algorithms. The values of performance index of the conventional type are compared with the simulation results of discrete lookup_table type and continuous simplified inference type.

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

The Effects of Soil factors on the Growth in Populus euramericana Guinier (토양인자(土壤因子)가 이태리 포플러의 생장(生長)에 미치는 영향)

  • Son, Doo Sik;Hong, Sung Chun;Joo, Sung Hyun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.14
    • /
    • pp.49-60
    • /
    • 1996
  • In order to evaluate soil factors affecting the growth of Italian poplar, 23 areas planted with Italian poplar were surveyed. These 23 areas were classified into 3 categories, river-side, fallow-land and hill-side. The growth performance and soil factors for each area were investigated. The growth of Italian poplar at river-side was shown to be superior to that of fallow-land and fill-side. The rates of growth for fallow-land and hill-side are decreased by 8% and 21% compared to those of river-side, respectively. This suggests that plantation of Italian poplar at hill-side would not be profitable. Soil conditions of high productive area appeared liquid phase 20%, porosity 45%, water holding capacity 35 - 40%, soil hardness $1kg/cm^3$. pH 6 and rich in organic matter and total nitrogen. The results of factor analysis for soil factors affecting to Italian poplar growth that showed eigenvalue over 1 and communality value over 70% explained factor 1 : liquid phase, porosity and water holding capacity, factor 2 : pH and calcium, and factor 3 : soil hardness. This suggests that physical characteristics of soil is more important than chemical characteristics for Italian poplar growth. Multiregerssion analysis was conducted between diameter growth and soil hardness, liquid phase and calcium. The t-values for each independent variables showed significance at 1 - 10% level, but water holding capacity and pH are not significant. It is supposed that sites suitable to Italian poplar were alluvial plain of sandy loam or part of banking soil, well-ventilating soil, lower soil hardness, apposite soil moisture absorbing with about 100cm of ground water level, plentiful organic matters and total nitrogen and little acidity soil.

  • PDF