• 제목/요약/키워드: veneering porcelain

검색결과 57건 처리시간 0.022초

Influence of surface modification techniques on shear bond strength between different zirconia cores and veneering ceramics

  • Mosharraf, Ramin;Rismanchian, Mansour;Savabi, Omid;Ashtiani, Alireza Hashemi
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.221-228
    • /
    • 2011
  • PURPOSE. Veneering porcelain might be delaminated from underlying zirconia-based ceramics. The aim of this study was the evaluation of the effect of different surface treatments and type of zirconia (white or colored) on shear bond strength (SBS) of zirconia core and its veneering porcelain. MATERIALS AND METHODS. Eighty zirconia disks (40 white and 40 colored; 10 mm in diameter and 4 mm thick) were treated with three different mechanical surface conditioning methods (Sandblasting with $110{\mu}m$ $Al_2O_3$ particle, grinding, sandblasting and liner application). One group had received no treatment. These disks were veneered with 3 mm thick and 5 mm diameter Cercon Ceram Kiss porcelain and SBS test was conducted (cross-head speed = 1 mm/min). Two and one way ANOVA, Tukey's HSD Past hoc, and T- test were selected to analyzed the data (${\alpha}=0.05$). RESULTS. In this study, the factor of different types of zirconia ceramics (P=.462) had no significant effect on SBS, but the factors of different surface modification techniques (P=.005) and interaction effect (P=.018) had a significant effect on SBS. Within colored zirconia group, there were no significant differences in mean SBS among the four surface treatment subgroups (P=0.183). Within white zirconia group, "Ground group" exhibited a significantly lower SBS value than "as milled" or control (P=0.001) and liner (P=.05) groups. CONCLUSION. Type of zirconia did not have any effect on bond strength between zirconia core and veneer ceramic. Surface treatment had different effects on the SBS of the different zirconia types and grinding dramatically decreased the SBS of white zirconia- porcelain.

지르코니아 코어 두께에 따른 전부도재관의 상부도재 축성방법이 보철물 색조에 미치는 영향 (The Effect of Veneering Techniques on the Color Parameters of Y-TZP Based All Ceramic Restoration of Varying Ceramic Core Thickness)

  • 허성윤;손호정;김혜영;김재홍
    • 치위생과학회지
    • /
    • 제12권2호
    • /
    • pp.123-129
    • /
    • 2012
  • 이 연구에서는 지르코니아 코어의 두께를 달리 제작하여 동일한 색조의 상부도재를 축성함에 있어 제작방법을 다르게 하여 두 상반된 시편을 각각 분광측색장치를 이용하여 CIE $L^*,a^*,b^*$ 색체계로 산출하여 객관적으로 색차를 비교, 분석하여 다음과 같은 결론을 얻었다. 1. 지르코니아 코어의 두께가 두꺼워 지고 상부도재의 두께가 얇아지면서 $L^*$ 값의 수치는 높아지며 $a^*,b^*$ 값은 낮아지는 경향을 띠었다. 상부도재 축성방법을 다르게 제작한 시편에서도 같은 결과를 보였다. 동일한 색조 시편에서 HP군은 PST군에 비해 $L^*$ 값의 수치는 낮게 측색되어 어두운 경향을 보였으며 $a^*,b^*$ 값도 낮은 수치를 보여 황색의 경향을 띠었다. 2. HP군, PST군 모두 동일한 색조에서 지르코니아 코어 두께와 상부도재 제작방법 간에 교호작용은 없었다(P=.083). 지르코니아 코어의 두께에 따라서는 통계적으로 유의한 차이는 존재하였으며(P=.001), 두께가 0.3 mm의 시편 A1, A2 색조에서 색차 값($E^*$)은 3.7 이상으로 나타났고, 그 이외 시편에서는 3.7 이하로 분석되어 임상가능 허용치로 나타났다. 이상의 결과로 볼 때 지르코니아를 이용한 전부 도재관 제작 시 같은 색조의 재료 일지라도 제작방식과 상부도재의 재료에 따라 색차 값이 존재하므로 이를 감안하여 보철물 제작에 사용해야 할 것으로 사료되며, 특히 코어의 두께가 얇은 보철물에서는 임상 허용치 이상의 색차 값을 보이므로 코어의 두께를 좀 더 추가하여 설계한 보철물이 바람직하다고 생각된다.

색소체용액 침투가 지르코니아 및 전장용 세라믹의 전단결합강도에 미치는 영향 (Influence of coloring liquids on the shear bond strength between zirconia and veneering ceramic)

  • 정종현;오계정
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.291-298
    • /
    • 2016
  • Purpose: This study was to evaluate the effect of coloring liquids on the shear bond strength between zirconia and veneering ceramic. Methods: Zirconia(15 mm in diameter, 2.5 mm in thickness; n=40) used in the experiment were divided into 5 groups depending on the coloring liquid. Each specimen were polished using a polishing machine(LaboPol-2, Struers, UK). A cylinder of veneering porcelain(6 mm in diameter, 3 mm in thickness) was fabricated and fired on zirconia surfaces. The shear bond strength was measured using a universal testing machine(Model 4302, Instron, USA). All data were analyzed statistically using a one-way ANOVA and Tukey's multiple comparisons test. After the shear bond test, fracture surfaces were examined by SEM. Results: Colored zirconia showed a higher shear bonding strength than that of uncolored zirconia except for colored zirconia immersed in Zirkonzahn coloring liquid. In particular, colored zirconia immersed in Kuwotech coloring liquid showed the highest shear bond strength. After the shear bond test, mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. Conclusion: Coloring liquid enhanced the shear bond strength zirconia and veneering ceramic than uncolored zirconia.

주조도재관과 도재전장주조관의 치경부 변연적합도에 관한 비교 연구 (A Comparative Study on the Marginal Fit between Castable Ceramic(Dicor) Crowns and Metal-Ceramic Crowns)

  • 김정호;양재호;이선형
    • 대한치과보철학회지
    • /
    • 제26권1호
    • /
    • pp.51-61
    • /
    • 1988
  • The recently introduced castable glass ceramics incorporate properties characteristic of natural teeth and they are regarded as an ideal material to restore lost tooth structure. The purpose of this study was to compare the marginal fit of castable ceramic crown with that of the metal-ceramic crown in the process of heat treatment. Two master dies for castable ceramic crowns and metal-ceramic crowns were fabricated from being cast with the base metal. Each master die was duplicated with addition silicone and hard stone. Ten castable ceramic crowns were made on each hard stone die and their marginal openings were measured three times first, after casting; second, after ceramming; third, after shading. The other ten metal-ceramic crowns were made on each hard stone die and their marginal openings were measured three times : first, after casting; second, after degassing; third, after porcelain veneering. Each crown was seated on its master die with the constant force delivered by loading jig. And then, marginal openings were measured on four locations by optical projector at X50 magnification. The results were as follows: 1. The mean marginal openings of castable ceramic crowns were $31.1{\pm}12.7{\mu}m$ after casting; $44.6{\pm}12.8{\mu}m$ after ceramming; $51.2{\pm}16.8{\mu}m$ after shading. 2. The mean marginal openings of the metal-ceramic crowns were $26.2{\pm}13.8{\mu}m$ after casting; $29.8{\pm}10.3{\mu}m$ after degassing; $38.0{\pm}14.5{\mu}m$ after porcelain veneering. 3. There was significant increase in the marginal opening of castable ceramic crowns after ceramming, while metal-ceramic crowns sho(wed significant increase after porcelain veneering (p<0.05). 4. Marginal fit of metal-ceramic crown was better than that of castable ceramic crown (p<0.01).

  • PDF

Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

  • Kwon, Taek-Ka;Pak, Hyun-Soon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.92-97
    • /
    • 2013
  • PURPOSE. All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS. The mean fracture strengths were as follows: $54.9{\pm}15.6$ N for the Lava CAD/CAM zirconia crowns and $87.0{\pm}16.0$ N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

The effect of various veneering techniques on the marginal fit of zirconia copings

  • Torabi, Kianoosh;Vojdani, Mahroo;Giti, Rashin;Taghva, Masumeh;Pardis, Soheil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.233-239
    • /
    • 2015
  • PURPOSE. This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). MATERIALS AND METHODS. Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (${\alpha}$=.05). RESULTS. Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group ($63.06{\mu}m$) was higher than press-over ($50.64{\mu}m$) and CAD-on ($51.50{\mu}m$) veneered groups (P<.001). CONCLUSION. Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CADon techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.

Optimization of Surface Treatment for Bonding S trength between Zirconia and Veneering Porcelain

  • Won, H.Y.;Kim, H.S.L.;Yun, C.H.;Son, M.K.;Cho, H.C.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.332-332
    • /
    • 2012
  • All-ceramic prostheses are widely used to fulfill the high esthetic demand. However, bonding failure between zirconia and porcelain is one of the all-ceramic prostheses failures. In order to improve clinical sucess of all-ceramic prostheses, laboratory or in-office surface conditioning techniques on zirconia have been studied.

  • PDF

Y-TZP ceramic의 표면처리에 따른 전장용 레진의 전단결합강도 (Effect of Conditioning Methods on the Shear Bond Strength of Veneering composite on Zirconia Ceramic)

  • 남현석;송광엽;안승근;박주미
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.253-264
    • /
    • 2010
  • 최근 개발된 Yttrium-stabilized-tetragonal-zirconia-polycrystal(Y-TZP ceramic)은 생체 친화적이며 높은 굴곡 강도, 파절 저항성, 파괴 인성을 지니고 CAD-CAM을 통해 milling이 가능하여 많은 치과 영역에서 사용되고 있다. 구치부 zirconia framework을 사용하는 고정성 수복물의 경우에는 상부 장석 도재의 상대적으로 높은 빈도의 파절을 보이고 있다. 복합레진은 취성이 적고 법랑질 보다 마모도가 낮으며 수리가 용이하다. 높은 교합압 부위에서 전장용 복합레진을 사용한 임플란트 수복은 기능적인 장점을 지니며 흥미롭게 여겨지고 있다. 이번 연구의 목적은 Y-TZP ceramic에 몇 가지 표면 처리를 시행하여 전장용 복합레진을 적용 시켰을 때 도재 전장시과 비교하여 임상적 활용을 위한 유용한 전단결합강도를 지니는지를 알고자 함이다.