• Title/Summary/Keyword: velocity relation

Search Result 608, Processing Time 0.023 seconds

Analysis of Ship Groundings on Soft Sea Beds

  • Simonsen, B. Cerup;Redersen, P. Terndrup
    • Journal of Ship and Ocean Technology
    • /
    • v.1 no.1
    • /
    • pp.35-47
    • /
    • 1997
  • The consequences associated with ships running aground depend very much on the soil characteristics of the sea bed and the geometrical shape of the ship bow. The penetration into the sea bed depends on these factors and the penetration is an important factor for the ship motion because it influences the ship heave and pitch motions as well as the friction between the ship and the soil. In this paper a rational calculation model is presented for the sea bed soil reaction forces on the ship bottom. The model is based on the assumption that the penetration of the ship bow generates a flow of pore water through the grain skeleton of the soil. The flow is governed by Darcy\`s law and it is driven by the pressure of the pore water at the bow. In addition to this pore water pressure, the bow is subjected to the effective stresses in the grain skeleton at the bow surface. These stresses are determined by the theory of frictional soils in rupture. Frictional stresses on the bow surface are assumed to be related to the normal pressure by a simple Coulomb relation. The total soil reaction as a function of velocity and penetration is found by integration of normal pressure and frictional stresses over the surface of the bow. The analysis procedure is implemented in a computer program for time domain rigid body analysis of ships running aground and it is verified in the paper through a comparison of calculated stopping lengths, effective coefficients of friction, and sea bed penetrations with corresponding experimental results obtained by model tests as well as large, scale tests.

  • PDF

The Stability Riprap on Scattered Submerged Breakwater due to Physical Model (난적잠제 상부 사석의 안정에 관한 실험적 연구)

  • Park, Sang-Kil;Kim, Woo-Saeng;Lee, Jae-Sung;Kim, Sung-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.106-115
    • /
    • 2010
  • This study described the stability of riprap, which was examined by a two-dimensional physical model of a scattered riprap submarine breakwater. Artificial reef structures made of scattered riprap are used like artificial intertidal zone structures as waterfront seaside structures. To prevent topography change in such an artificial intertidal zone the energy is reduced at the scattered riprap submarine breakwater by intercepting high waves. The breaking waves are converted into flow on the front surface slope of the submarine breakwater, which follows the upper part of the artificial intertidal zone. Because of this phenomenon of resisting water flow, it is very important to calculate the required weight of the riprap to maintain its stability. The results of a physical model can be abstracted as shown below. First, distribute the wave breaking types occurring on the front surface slope of the submarine breakwater and arrange it in relation to the movement of riprap. Second, using the hydraulic phenomenon that occurs at the depth of the scattered riprap submarine breakwater, propose a calculation formula for the velocity distribution showing the influence on the stability of the riprap. Third, propose and compare values, which can be obtained by experiments and calculations for riprap stability on the front surface of the artificial intertidal zone. Fourth, calculate the required weight for riprap stability.

Analysis on Mandibular Movement of Temporomandibular Disorder Patients using Mandibular Kinesiograph (Mandibular Kinesiograph를 이용한 측두하악장애환자의 하악운동 분석)

  • Woo-Cheon Kee;Byung Gook Kim;You-Kyung Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.185-194
    • /
    • 1995
  • The purpose of this study was to estimate primary diagnosis, prediction of prognosis and recognition fo treatment progress for treatment of TMD patients through measuring the various ranges of mandibular movement in normal and TMDs patients using Mandibular Kinesiograph K-6 Diagnostic system. In normal groups, 20 adults were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. In Patients group, we selected 31 outpatients who were confirmed to TMDs with clinical examination and radiographic findings. The obtained results were as follows : 1. In maximal opening, patient group was showed the limitation of vertical movement range (P<0.01) and lager lateral deviation than in normal group (P<0.05). And actual dimensional displacement of opening was calculated larger in normal group (P<0.05). 2. In protrusive movement, patients group was showed the limitation of anteroposterior movement range (P<0.001) and larger deviation than in normal group (P<0.01). And actual 3 dimensional displacement of protrusion was calculated larger in normal group (P<0.001). 3. In lateral maximum excursion, compared with normal group patient group was no significant differences to affected side, but was showed the limitation of lateral movement to unaffected side (P<0.001). 4. There was no significant difference in movement velocity of opening and closing in both groups. 5. Mandibular movement from physiologic rest position to centric occlusion was moved more anteroposteriorly in patient group. 6. Mandibular movement from centric relation to centric occlusion was no significant difference in both groups.

  • PDF

Effects of Accelerometer Signal Processing Errors on Inertial Navigation Systems (가속도계 신호 처리 오차의 관성항법장치 영향 분석)

  • Sung, Chang-Ky;Lee, Tae-Gyoo;Lee, Jung-Shin;Park, Jai-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.71-80
    • /
    • 2006
  • Strapdown Inertial navigation systems consist of an inertial sensor assembly(ISA), electronic modules to process sensor data, and a navigation computer to calculate attitude, velocity and position. In the ISA, most gryoscopes such as RLGs and FOGs, have digital output, but typical accelerometers use current as an analog output. For a high precision inertial navigation system, sufficient stability and resolution of the accelerometer board converting the analog accelerometer output into digital data needs to be guaranteed. To achieve this precision, the asymmetric error and A/D reset scale error of the accelerometer board must be properly compensated. If the relation between the acceleration error and the errors of boards are exactly known, the compensation and estimation techniques for the errors may be well developed. However, the A/D Reset scale error consists of a pulse-train type term with a period inversely proportional to an input acceleration additional to a proportional term, which makes it difficult to estimate. In this paper, the effects on the acceleration output for auto-pilot situations and the effects of A/D reset scale errors during horizontal alignment are qualitatively analyzed. The result can be applied to the development of the real-time compensation technique for A/D reset scale error and the derivation of the design parameters for accelerometer board.

An Investigation on the Spray Characteristics of a Compressed Natural Gas Injector (고압 천연 가스 인젝터의 분무 특성에 관한 연구)

  • THONGCHAI, SAKDA;KANG, YUJIN;LIM, OCKTAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.219-225
    • /
    • 2018
  • This study was carried out to investigate the injection characteristics of 800 kPa compressed natural gas compressed natural gas (CNG) injector developed in Korea. The CNG injector with multi-holes, employed in this experiment, was designed to inject CNG in the manifold at high pressure of 800 kPa. The spray macroscopic visualization test was carried out via Schlieren photography to study fuel-air mixing process. The fundamental spray characteristics, such as spray penetration, spray cone angle and spray velocity, were evaluated in the constant volume combustion chamber (CVCC) with varying the constant back pressure in CVCC from 0 to 1.8 bar. For the safety reason, nitrogen ($N_2$) and an acetone tracer were utilized as a surrogate gas fuel instead of CNG. The surrogate gas fuel pressures were controlled at 3, 5.5, and 8 bar, respectively. Injection durations were set at 5 ms throughout the experiment. The simulating events of the low engine speed were arranged at 1,000 rpm. The spray images were recorded by using a high-speed camera with a frame rate of 10,000 f/s at $512{\times}256pixels$. The spray characteristics were analyzed by using the image processing (Matlab). The results showed the significant difference that higher injection pressure had more effect on the spray shape than the lower injection pressure. When the injection pressure was increased, the longer spray penetration occurred. Moreover, the linear relation between speed and time are dependent on the injection pressure as well.

On the AR Coating Method of Al-MIS(p-Si) Solar Cel (Al-MIS(p-Si) 태양전지의 AR Coating 방법)

  • 엄경숙;백수현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.6
    • /
    • pp.64-69
    • /
    • 1984
  • We found that the maximum efficiency of Al-MIS (p-Si) solar ceil was shown at 80$\AA$ thickness of Al-film which was deposited with slower velocity than 0.6$\AA$/sec. It was coated with ZnS and SiO for Anti-Reflecting. In single coating, ZnS and SiO film had maximum Isc at 570 and 690 A thickness, respectively. We confirmed that these results agreed well with the quarter coating condition; n1d1=λ/4. In double coating, we held the one layer with its optimum thickness in single coating and controlled the other layer. The maximum value of Isc in this case was almost the same with it in single coating but was maintained its value in so wide range of thickness. Keeping the relation; n1d1=n2d2 as another way, we made the total thickness of film thinner to 70-90% of the sum of each optimum thickness in single coating. In this case Isc was higher value than 20% of it in any other previous case and was retained so wide range of thickness.

  • PDF

Simple Method for Improving the Frequency Sweep Linearity of FMCW Collision Warning Radar (차량 충돌방지용 FMCW 레이더의 주파수 Sweep 선형성 개선을 위한 간단한 기법)

  • Hyun, Eu-Gin;Oh, Woo-Jin;Lee, Jong-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1109-1115
    • /
    • 2010
  • FMCW(Frequency Modulation Continuous Wave) Radar can detect the distance and the velocity of forward obstacles using linearly modulated FM signal. For better performance, the RF of radar should be operated with wideband frequency linearity on 300 MHz bandwidth at 77 GHz carrier frequency. In this paper, we propose a simple method for improving frequency linearity of FMCW radar implemented with VCO. The proposed method shows that the Voltage-Frequency relation of VCO could be measured by using the modified Tx waveform of FMCW radar. Then the measured nonlinearity could be compensated using LUT(Look-up Table) with easy. It is noted that the proposed can be adopted in existing system without extra circuit.

Facilitation of Quadriceps Activation Following a Concentric Knee Flexion During Reciprocal Knee Movement: The Influence of Muscle Preloading (교차적 슬관절 굴곡-신전 시 슬관절 굴곡근의 구심성 수축에 의한 선행부하가 대퇴사두근의 활성화에 미치는 영향)

  • Jeon, Hye-Seon;Trimble, Mark H.;Brunt, Denis
    • Physical Therapy Korea
    • /
    • v.10 no.4
    • /
    • pp.1-15
    • /
    • 2003
  • 본 연구는 슬관전 신전 직전에 수행된 선행 슬관절 굴곡이 슬관절 신전근의 최대 근력발생 및 근육 활성도(activation)에 미치는 영향을 알아보기 위하여 실시되었다. 16명의 정상인이 Cybex II 등속운동기구에서 3가지 다른 운동 속도($100^{\circ}/s$, $200^{\circ}/s$, $300^{\circ}/s$)와 2가지 다른 근육 활성 조건(선행부하가 없는 조건과 선행부하 조건)에서 슬관절의 최대 신전을 수행하였다. 연구대상자들에게 선행부하 없는 조건에서는 $90^{\circ}$ 슬관절 굴곡 상태에서 $0^{\circ}$까지 최대 신전을 수행하도록 하였고, 선행부하 조건에서는 구심성 슬와부 근육의 구심성 수축으로 $0^{\circ}$에서 $110^{\circ}$까지 굴곡한 후, 다시 $0^{\circ}$까지 최대 신전을 하도록 요구하였다. 종속변인으로는 내측광근과 외측광근의 최대 근전도와 최대 신전근력을 측정하였다. 실험 결과 최대 근전도와 최대 근력 모두 선행부하 조건에서 높게 나타났으며, 운동 속도가 증가함에 따라 최대 근력은 감소하는 전형적인 최대 근력-운동속도 상관법칙이 본 실험에서도 나타났다. 또한 운동속도와 전환속도 간의 간섭이 없는 것으로 나타나, 슬관절 신전근에 선행부하(preloading)를 가하는 것이 최대 근력-운동속도 상관법칙(force-velocity relation)에 영향을 미치지 못하는 것으로 해석되었다. 선행부하로 인해 증가된 최대 근력 및 근 활성도의 증가는 주로 신경촉진에 의한 것으로 해석된다.

  • PDF

CAE/CFD Analysis and Design of High-Pressure Drop Control Valve for Offshore Project (해양플랜트용 고차압 제어밸브의 해석 및 설계)

  • Jang, Sung Cheol;Park, Tae-Soo;Hur, Nam-Soo;Kim, In-Whan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.42-49
    • /
    • 2015
  • In this study, the multi-disk of a high-pressure drop control valve is designed and manufactured. Then, the flow rate and high-pressure drop of fluids flowing in the high-pressure drop control valve is CAE/CFD. This study involves numerical analysis for the Zambil offshore project of a high-pressure drop control valve. ANSYS used a solver for offshore structures analysis. A high-pressure drop control valve, which transforms the power transfer of a system by reducing the inlet pressure of 345bar to the outlet pressure of 112bar, is a fundamental component in the offshore process. This study not only analyzes the relation between pressure drop and fluid velocity in a trim by using fluid analysis, but also examines the possibility of cavitation in a valve in addition to the plot for the extension of lifespan. It is demonstrated that the pressure drop from 345bar to 112bar is more feasible in the presence of the trim, which can induce a continuous and diminutive pressure drop in order to prevent cavitation in a high-pressure drop control valve.

A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅰ). Improvements of the Dialysis Apparatus and Its Operations (透膜法에 依한 이온量 및 分子量의 決定에 關한 硏究 (I) 透析裝置 및 實驗方法의 改良)

  • Shin Yun Kyong;Rhee Jhun
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.304-313
    • /
    • 1972
  • This paper reports the improvements of the dialysis apparatus and operations since there are some problems to be improved in the dialysis method which is applied to determine the ionic and molecular weight of dissolved particles. The hook gauge was utilized in order to control the surface level of the dialysing solution and the solvent to be equal with the precision of 0.02 mm to minimize the osmotic and filtration effects. An accurate agitation velocity for both solutions was maintained and so was the same temperature for both solutions with ${\pm}0.01^{\circ}C$ precision. The dialysis membrane was fixed uniformly and flatly on one end of the dialysis cylinder by using a newly developed ring. The volume change of the dialysing solution during the dialysis was reduced to the range of -1.62 ~ +0.92%. Optimum duration of dialysis was searched from the relation between the osmotic and filtration effect and the pore size of the membrane.

  • PDF