• Title/Summary/Keyword: varistor voltage

Search Result 239, Processing Time 0.026 seconds

A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor (옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

Study on the Causes of Malfunctions of PCBs Applied to the Power Saving Mode of Electrical Systems and its Solution (전기시스템의 절전모드에 적용되는 PCB의 오작동 원인 개선에 관한 연구)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.51-55
    • /
    • 2013
  • The purpose of this study is to find the causes of malfunctions and defective operation of printed circuit boards(PCBs) built into home refrigerators to perform power saving functions. This study performed an electrostatic test of a PCB built-in using an Auto Triggering system; lightning and impulse tests using an LSS-15AX; and an impulse test using an INS-400AX. From the analysis of a secondarily developed product, it was found that electrostatic discharge(ESD) caused more malfunctions and defective operations than electric overstress(EOS) due to overvoltage. As a result of increasing the condenser capacity of the PCB circuit, withstanding voltage was increased to 7.4 kV. In addition, this study changed the power saving mode and connected a varistor to the #2 pin of an IC chip. As a result, the system consisting of all specimens of a finally developed product was operated stably with an applied voltage of less than 10 kV. This study found it necessary to perform quality control at the manufacturing stage in order to reduce the occurrence of electrostatic accidents to IC chips built into a PCB.

Fabrication and Performance Evaluation of Zinc Oxide Varistors for the Arresters used for Station System (발변전소 피뢰기용 산화아연소자의 제작 및 성능평가)

  • Cho, Han-Goo;Han, Se-Won;Kim, Suk-Soo;Yoon, Han-Soo;Lee, Un-Yong;O, Cheol-Gyu;Yu, Kun-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.636-639
    • /
    • 2004
  • This paper presents the fabrication and performance evaluation of zinc oxide varistors for the arresters used for station system. ZnO varistors were fabricated with typical ceramic production methods and the structural and electrical characteristics were investigated. All varistors exhibited high density, which were in the range of $5.41{\sim}5.49g/cm^3$. In the electrical properties the reference voltage increased in the range of $4.410{\sim}5.250kV$ with increasing their thickness and the residual voltage exhibited the same trends as the reference voltage. In the long duration current impulse withstand test, E-2 and F-1 samples failed in the two and four shots, respectively, but E-1 and F-2 samples survived 18 shots during the test. Before and after this test, the variation ratio of residual voltage of E-1 and F-2 samples were -0.34% and 0.05%, respectively, which were in the acceptance range of 5%. According to the results of tests, it is thought that if the fabrication process such as insulating coating, sintering condition, and soldering method is improved, these ZnO varistors would be possible to apply to the station class arresters in the new future.

  • PDF

Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages (서지전압에 대한 50[A]용 누전차단기의 부동작 특성)

  • 이승칠;장석훈;이복희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.44-52
    • /
    • 1997
  • Electronic circuits with semiconductor and IC are very weak against the surge voltage and currents. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of the earth leakage circuit breaker(ELB) due to the operation of surge protective devices, and the interruption of AC power lines on account of the malfunction of the ELB brings about several disadvantages such as low operation efficiency and reliability of electronic and informational systems, economical loss, and etc. The aim of the present work is to investigate the dead operation characteristics of the ELB against the surge voltages. The impulse generator of 10[kV) in an 1.2/ 50[~) voltage waveform was fabricated. The dead operation characteristics of the ELB applied by surge voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a consequence, the peak value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not bring about dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELB installed at the AC power lines with the surge protective devices bring about the dead operation.

  • PDF

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

Microstructure and Electrical Properties of ZPCCYT Varistor Ceramics

  • Nahm, Choon-Woo;Lee, Sun-Kwon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.262-265
    • /
    • 2012
  • The Microstructure and nonlinear electrical properties of the ZPCCYT (ZnO-$Pr_6O_{11}$-CoO-$Cr_2O_3$-$Y_2O_3$-$Tb_4O_7$) varistors were investigated for different amounts of $Tb_4O_7$. The addition of $Tb_4O_7$ has a significant effect on microstructure and electrical properties. Analysis of the microstructure indicated that the ceramics consisted of ZnO grain as a main phase and a few secondary phases as a mix of $Pr_6O_{11}$, $Y_2O_3$, and $Tb_4O_7$. As the amount of $Tb_4O_7$ increased, the sintered densities of pellets increased from $\rho$ = 5.70 to $5.78g/cm^3$ and the average grain size decreased from d = 4.8 to $3.6{\mu}m$. The increase in the amount of $Tb_4O_7$ increased from $E_B$ = 7,473 to 10,035 V/cm and from ${\alpha}$ = 39.7 to 52.2. In particular, it was found that the ceramics modified with 1.0 mol% in the amount of $Tb_4O_7$ are suited for the varistors for high voltage in the light of a high sintered density and a high voltage gradient.

Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices (MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • Protection against lightning surge is an essential part of almost any electrical and electronic equipment today. Metal Oxide Varistor(MOV) is the single most important component in the overwhelming majority of the Surge Protective Devices(SPD) designated to provide such protection. In this paperr various types of MOV based SPD are inspected and experiments are carried out on the side effects of the low Measured Limiting Voltage(MLV) characteristics. Experiment results show that a lower MLV could cause a higher Temporary Overvoltage(TOV)-induced SPD failure rate in the field, and SPD are more likely to be victims rather than protectors in a TOV scenario. This means that from a safety perspective, the SPD should be specified with higher TOV withstand capability(UT) and faster SPD disconnector.

The characteristic of leakage current of ZnO block varistor according to fault conditions of three-phase four-wire distribution system (3상 배전계통의 고장조건에 따른 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee, B.H.;Choi, H.S.;Kang, S.M.;Park, K.Y.;Lee, S.B.;Oh, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.174-177
    • /
    • 2003
  • Kinds of most frequent faults happened on overhead distribution system are the single line-to-ground fault, the line-to-line fault and the two line-to-ground fault. Occasionally, the three line-to-ground fault and the disconnection of a wire are happened in severe conditions. In this study, the single line-to-ground fault, the line-to-line fault, two line-to-ground fault on three-phase four-wire overhead distribution system were experimentally simulated and characteristics of total leakage current of distribution arrester caused by these faults were investigated. Also, the changing aspect of total leakage current of distribution arrester caused by voltage variation was investigated. In a consequence, abnormal voltages caused by voltage variation, the line-to-line fault, the two line-to-ground fault have a little effect on total leakage current of ZnO arrester. But abnormal voltages caused by the single line-to-ground fault have an important effect on total leakage current of ZnO arrester.

  • PDF

Nonlinearity and Degradation Characteristics of $Pr_{6}O_{11}$-Based ZnO varistors Doped with $Er_{2}O_3$ ($Er_{2}O_3$가 첨가된 $Pr_{6}O_{11}$계 ZnO 바리스터의 비직선성 및 노화특성)

  • Yoon, Han-Soo;Ryu, Jung-Sun;Nahm, Choon-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1673-1675
    • /
    • 2000
  • The nonlinearity and degradation characteristics of $Pr_{6}O_{11}$-based ZnO varistors doped with, $Er_{2}O_3$ were investigated. The varistors were sintered at 1335$^{\circ}C$ in the addition range of 0.0 to 2.0 mol% $Er_{2}O_3$, respectively The varistor doped with $Er_{2}O_3$ exhibited more higher nonlinearity than that without $Er_{2}O_3$. Most of the varistors containing 0.5 mol% $Er_{2}O_3$ showed nonlinear exponent more than 70 and a excellent stability, which the variation rate of the varistor voltage and the nonlinear exponent is -0.85% and -1.43%. respectively, even under 3rd d.c stress, such as (0.80 $V_{1mA}/90^{\circ}C$/12h)+(0.85$V_{1mA}/115^{\circ}C$/12h)+(0.90$V_{1mA}/120^{\circ}C$/12h). Consequently, since $Pr_{6}O_{11}$-based 2nO varistors doped with 0.5 mol% $Er_{2}O_3$ have an excellent stability as well as good nonlinearity, it is expected to be usefully used to develop the advanced varistors in future.

  • PDF

Impulse Characteristics of MOV Elements for Railroad Vehicle Arrester (전철 탑재 피뢰기용 MOV 소자 임펄스 특성)

  • Han, S.W.;Cho, H.G.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1529-1531
    • /
    • 1999
  • The main functions of AC railroad vehicles arresters is to protect the main transformer from lightening impulse or switching impulse surge, then the MOV(metal oxide varistor) elements rated of 10kA is applied. The residual voltage and surge energy absorption are important parameters in designing arrester, these must be carefully decided with considering protecting level of impulse environment of system. The purpose of this study is to discuss the residual voltages and the energy absorption capability by impulse currents on MOV elements for railroad vehicles, and to introduce design factors which act as optimal protecting condition against impulse currents.

  • PDF