• 제목/요약/키워드: variable power factor

검색결과 280건 처리시간 0.027초

단상 AC/DC 승압형 컨버터를 이용한 피복 아크 용접기 역률 개선에 관한 연구 (A Study On Power Factor Correction of SMAW(shielded metal-arc welding) Using Single Phase AC/DC Boost Converter)

  • 유영진;김이훈;김준호;원충연;김영렬;이상용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.556-559
    • /
    • 2001
  • In this paper, we proposed AC/DC boost converter to improve input current harmonic reduction in SMAW(shielded metal-arc welding). The proposed harmonic reduction with the boost converter design and the UC2854 integrated circuit which controls the converter, The topology of welding power supply is made of a pair of boost converter and welder half-bridge IGBT inverter. The voltage arc is modeled by a variable resistance in series with a voltage source. The results has been confirmed by PSIM simulation tool. The simulation results show that input at current is nearly sinusoidal with low harmonic contents and sinusoidal input current waveform at high power factor.

  • PDF

발전소 건설프로젝트 품질관리에 영향을 미치는 요인에 관한 연구 : 원전 건설 집단민원 사례를 중심으로 (A Study on the Influential Factors to Power Plant Construction Project Quality Control : Focused on Collective Civil Complaints of Nuclear Power Plant Construction)

  • 안성식;정재만
    • 품질경영학회지
    • /
    • 제46권2호
    • /
    • pp.351-374
    • /
    • 2018
  • Purpose: The collective civil complaint problem is considered as important obstructive factor of the nuclear power plant construction project's success and quality. Therefore, this study demonstrate the factors which can affect the settling collective civil complaints, and also suggest the improvement of the resolution. Methods: This study collected the data of Kori Nuclear Power Division staff, local residents and Hanul Nuclear Power Division staff, local residents, and use them for analysis. Results: The results are twofold in the study: First, the 'Situation Recognition' and 'Mutual Cooperation' which are independent variables for solving collective civil complaints have proved to give positive influence on both the nuclear staff and the local residents about the complaint resolution outcome of the dependent variable. Second, the moderation variable 'Expected Benefit' on the influential relationship between the collective civil complaint resolution factor and the civil complaints resolution outcome proved to have a moderating effect only on the nuclear staff. On the other hand, moderation variables 'Time of SOC Business Implementation' and 'Time of Compensation' proved to have a moderating effect only for the local residents. Conclusion: According to the results, the staff have a positive opinion on the benefits of the nuclear power plant construction, while residents feel strongly that they do not get any benefit from the construction despite of tremendous investment and expected benefit in local area. As this results, policy implementation which is superable different understanding is required.

이동식 에너지 뱅크용 대용량 배터리 충전 시스템의 개발 (Development of the High Power Battery Charging System for Portable Energy Banks)

  • 김수연;김동옥;이정환;박성준
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.491-499
    • /
    • 2021
  • Batteries are widely used for energy storage, such as ESS(Energy Storage System), electric vehicles, electric aircraft, and electric powered ships. Among them, a submarine uses a high power battery for an energy storage. When the battery of a submarine is discharged, a diesel generator generates AC power, and then AC/DC power converter change AC power to DC power for charging the battery. Therefore, in order to lower the current capacity of the diesel generator, it is necessary to use an AC/DC converter with a high input power factor. And, a power converter with a large power capacity must have high stability because it can lead to a major accident when a failure occurs. However, the control algorithm using the traditional PI controller is difficult to satisfy stability and dynamic characteristics. In this paper, we design the high power AC/DC converter with high input power factor for battery charging systems. And, we propose a stable control algorithm. The validity of the proposed method is verified through simulation and experiments.

LED Driver with TRIAC Dimming Control by Variable Switched Capacitance for Power Regulation

  • Lee, Eun-Soo;Sohn, Yeung-Hoon;Nguyen, Duy Tan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.555-566
    • /
    • 2015
  • A TRIAC dimming LED driver that can control the brightness of LED arrays for a wide range of source voltage variations is proposed in this paper. Unlike conventional PWM LED drivers, the proposed LED driver adopts a TRIAC switch, which inherently guarantees zero current switching and has been proven to be quite reliable over its long lifetime. Unlike previous TRIAC type LED drivers, the proposed LED driver is composed of an LC input filter and a variable switched capacitance, which is modulated by the TRIAC turn-on timing. Thus, the LED power regulation and dimming control, which are done by a volume resistor in the same way as the conventional TRIAC dimmers, can be simultaneously performed by the TRIAC control circuit. Because the proposed LED driver has high efficiency and a long lifetime with a high power factor (PF) and low total harmonic distortion (THD) characteristics, it is quite adequate for industrial lighting applications such as streets, factories, parking garages, and emergency stairs. A simple step-down capacitive power supply circuit composed of passive components only is also proposed, which is quite useful for providing DC power from an AC source without a bulky and heavy transformer. A prototype 60 W LED driver was implemented by the proposed design procedure and verified by simulation and experimental results, where the efficiency, PF, and THD are 92%, 0.94, and 6.3%, respectively. The LED power variation is well mitigated to below ${\pm}2%$ for 190 V < $V_s$ < 250 V by using the proposed simple control circuit.

PWM-based Integral Sliding-mode Controller for Unity Input Power Factor Operation of Indirect Matrix Converter

  • Rmili, Lazhar;Hamouda, Mahmoud;Rahmani, Salem;Blanchette, Handy Fortin;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1048-1057
    • /
    • 2017
  • An indirect matrix converter (IMC) is a modern power generation system that enables a direct ac/ac conversion without the need for any bulky and limited lifetime electrolytic capacitor. This system also allows four-quadrant operation, generation of sinusoidal output voltage waveforms with variable frequency and amplitude, and control of input power factor. This study proposes a pulse-width modulation-based sliding-mode controller to achieve unity input-power factor operation of the IMC independently of the active power exchanged with the grid, as well as a fast dynamic response. The designed equivalent control law determines, at each sampling period, the appropriate q-axis component of the modulated input current to be injected into the grid through the LC input filter. An integral term of the error is included in the expression of the sliding surface to increase the accuracy of the control method. A double space vector modulation method is used to synthesize the direction of the space vector of the input currents as required by the sliding-mode controller and the space vectors of the target output voltages. Simulation and experimental results are provided to show the effectiveness and evaluate the performance of the proposed control method.

LED 정전류 구동회로의 입력전압 리플 크기에 의한 특성 비교 (Characteristic comparisons of the constant current LED driver by the ripple of the input voltage)

  • 박종연;전인웅;유진완;최영민
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.115-118
    • /
    • 2012
  • Recently, there are a lot of papers in order to replace the electrolytic capacitor into the film capacitor in output of PFC(Power Factor Correction). However, the film capacitor, which has capacitance of low values, causes a large ripple voltage in output of PFC. The LED drivers are connected series in the output of PFC and affected by the magnitude of voltage ripple. In this paper, we have compared the fixed frequency method with the variable frequency for the constant-current control and propose the control method to avoid the sub-harmonic oscillation in the variable input voltage. An 80W PFC, using film capacitors instead of electrolytic capacitors, and LED driver has been built and compared the fixed frequency control method with the variable frequency control method.

  • PDF

부분안전계수를 이용한 감육배관의 신뢰도 기반 건전성 평가 (Reliability-Based Structural Integrity Assessment of Wall-Thinned Pipes Using Partial Safety Factor)

  • 이재빈;허남수;박치용
    • 한국생산제조학회지
    • /
    • 제22권3_1spc호
    • /
    • pp.518-524
    • /
    • 2013
  • Recently, probabilistic assessments of nuclear power plant components have generated interest in the nuclear industries, either for the efficient inspection and maintenance of older nuclear plants or for improving the safety and cost-effective design of newly constructed nuclear plants. In the present paper, the partial safety factor (PSF) of wall-thinned nuclear piping is evaluated based on a reliability index method, from which the effect of each statistical variable (assessment parameter) on a certain target probability is evaluated. In order to calculate the PSF of a wall-thinned pipe, a limit state function based on the load and resistance factor design (LRFD) concept is first constructed. As for the reliability assessment method, both the advanced first-order second moment (AFOSM) method and second-order reliability method (SORM) are employed to determine the PSF of each probabilistic variable. The present results can be used for developing maintenance strategies considering the priorities of input variables for structural integrity assessments of wall-thinned piping, and this PSF concept can also be applied to the optimal design of the components of newly constructed plants considering the target reliability levels.

Active clamp 컨버터의 주파수 변조 제어 (Frequency modulation control for active clamp converter)

  • 백주원;손호섭;류명효;유동욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.73-76
    • /
    • 2003
  • A zero voltage soft switching inverter using active clamp is presented for induction heating application. This converter have long been attractive because of its simplicity, high efficiency, and low cost compared to other schemes. In addition to those merits, Input power factor can be improved with a variable frequency control. In this paper, it describe the control method and operational principle to improve a power factor with a single stage US converter using active clamp for induction heating application.

  • PDF

단일전력단으로 구성된 역률 보상 AC/DC Full-Bridge Converter의 소프트 스위칭 기법에 대한 비교 연구 (A Comparative Study on Soft Switching Method of Single Stage AC/DC Full-Bridge Converter)

  • 이성룡;전칠환;정채규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.694-697
    • /
    • 2001
  • A optimal soft switching technique for A/DC full bridge converter is proposed. variable soft switching single stage AC/DC full bridge converter with unit power factor are presented in this paper. Using soft switching, we can reduce a switching losses. As a result, achieving good power factor and achieving a good efficiency. We search a optimal soft switching technique in this paper and to verify the theoretical analysis of the presented AC/DC full bridge converter, a design example is given with its Pspice and Psim simulation and experimental results.

  • PDF

A Single-Stage AC/DC Converter with Low Voltage Stresses and Reduced Switching Losses

  • Kim, Kyu-Tae;Choi, Woo-Young;Kwon, Jung-Min;Kwon, Bong-Hwan
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.823-834
    • /
    • 2009
  • This paper proposes a high-efficiency single-stage ac/dc converter. The proposed converter features low voltage stresses and reduced switching losses. It operates at the boundary of discontinuous- and continuous-conduction modes by employing variable switching frequency control. The turn-on switching loss of the switch can be reduced by turning it on when the voltage across it is at a minimum. The voltage across the bulk capacitor is independent of the output loads and maintained within the practical range for the universal line input, so the problem of high voltage stress across the bulk capacitor is alleviated. Moreover, the voltage stress of the output diodes is clamped to the output voltage, and the output diodes are turned off at zero-current. Thus, the reverse-recovery related losses of the output diodes are eliminated. The operational principles and circuit analysis are presented. A prototype circuit was built and tested for a 150 W (50V/3A) output power. The experimental results verify the performance of the proposed converter.