• Title/Summary/Keyword: variable capacity

Search Result 770, Processing Time 0.028 seconds

Experimental study on the compression of concrete filled steel tubular latticed columns with variable cross section

  • Yang, Yan;Zhou, Jun;Wei, Jiangang;Huang, Lei;Wu, Qingxiong;Chen, Baochun
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.663-675
    • /
    • 2016
  • The effects of slenderness ratio, eccentricity and column slope on the load-carrying capacities and failure modes of variable and uniform concrete filled steel tubular (CFST) latticed columns under axial and eccentric compression were investigated and compared in this study. The results clearly show that all the CFST latticed columns with variable cross section exhibit an overall failure, which is similar to that of CFST latticed columns with a uniform cross section. The load-carrying capacity decreases with the increase of the slenderness ratio or the eccentricity. For 2-m specimens with a slenderness ratio of 9, the ultimate load-carrying capacity is increased by 3% and 5% for variable CFST latticed columns with a slope of 1:40 and 1:20 as compared with that of uniform CFST latticed columns, respectively. For the eccentrically compressed variable CFST latticed columns, the strain of the columns at the loading side, as well as the difference in the strain, increases from the bottom to the cap, and a more significant increase in strain is observed in the cross section closer to the column cap.

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Effects of Limited Capacity on Screening Procedures Using a Surrogate Variable (대용특성을 활용한 스크리닝 검사에서 제한된 생산용량의 효과분석)

  • Choi, Ik-Jun;Hong, Sung-Hoon
    • Journal of Korean Society for Quality Management
    • /
    • v.36 no.4
    • /
    • pp.77-86
    • /
    • 2008
  • Due to the rapid growth in automated testing and manufacturing systems, screening inspection becomes very attractive. In this paper, we investigate the effects of limited capacity on screening inspection using a surrogate variable. The model is developed under the assumption that the reprocessed and nonreprocessed items are produced by the same manufacturing process and therefore their quality characteristics are independently and identically distributed. Profit models are constructed which involve four price/cost components; selling price, cost incurred by imperfect quality, reprocessing and quality inspection costs. Methods of finding the optimal screening limits are presented, and a numerical example is given. Sensitivity analyses are also performed to study the effect of a process standard deviation on this model.

Model Test of O-Cell Pile Load Test with Variable End Plate (가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험)

  • Joo, Yong-Sun;Kim, Nak-Kyung;Kim, Sung-Kyu;Kim, Ung-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

Difference of Vital Capacity According to Cranio-Vertebral Angle and Posture Change of Forward Head Posture People (두부전방전위자세에서 두개척추각과 자세변화에 따른 폐활량의 차이)

  • Kim, Ji-Yeon;Park, Eun-Ji;Yu, Ji-Min;Lee, Myoung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.1
    • /
    • pp.44-51
    • /
    • 2018
  • Background: In this paper, the relationship between the Cranio-Vertebral Angle (CVA) and the vital capacity in each position is reviewed, and the vital capacity in the position is studied. Methods: This study targeted 20 non-smoking female students of U university, which is located in Gyeongju-si. To review the Forward Head Posture (FHP) of each subject, CVA was measured, and FVC, FEV1, and FEF (25-75%) were measured and analyzed using a spirometer. Subjects were ordered to exhale three times with ease and then inhale up to their total lung capacity. After then, they were requested to exhale longer than six seconds. Then the inspiration and expiration were repeated. The measurement was executed in three positions, including supine, prone, and sitting. In each position the measurement was repeated twice, and a one-minute break was given between each cycle, so it was measured six times in total. SPSS 14.0 for Windows was used to analyze the data. The subjects' general properties were analyzed using descriptive statistics, and the correlation between the angle and the respiration variable result in each position was analyzed. The result of the respiration variable in each position was analyzed using the one-way ANOVA, and then a Scheffe post-hoc comparison was executed. Results: According to the analysis result of the correlation between the angle and respiration variable in each position, the sitting position and FEF (25-75%) showed a positive correlation (P<0.05). The respiration variable in each position showed a significant difference in FVC (p<0.05), and the Scheffe post-hoc comparison differed in prone and sitting positions. Conclusion: To increase the FVC of FHP patients, different exercises for each position can be applied, and the result of this study can be utilized as background data for further research.

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Improvement of Variable Renewable Energy Penetration of Stand-Alone Microgrid Hosting Capacity by Using Energy-Storage-System Based on Power Sensitivity

  • CHOI, DongHee
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.91-101
    • /
    • 2020
  • Recently, the demand for high penetration of variable renewable energy (VRE) penetration in a power system is increased. In consequence, distribution systems including microgrids confront the increased installation of VRE-based distributed generation. Despite of the high demand of VRE-based distributed generation in a distribution system, the installation of photovoltaic (PV) system in a distribution system has been restricted by various problems. In other words, the hosting capacity for high VRE penetration in a distribution system is limited. This paper analyzes the improvements of hosting capacity VRE penetration of stand-alone microgrid (SAMG) with energy storage system (ESS) by considering virtual-slack (VS) control based on power sensitivity. With the pre-defined power sensitivity, the ESS operates as virtual slack in the SAMG by controlling its bus voltage and phase angle indirectly. Therefore, the ESS enables the increase of VRE penetration in the SAMG. The proposed VS control is realized by analyzing the ESS as a virtual slack in power flow analysis based on power sensitivity. Then its validity is demonstrated with the case study on the SAMG in South Korea with practical data.

Design of a Variable-Stiffness Type Safety Joint for Service Robots (서비스 로봇용 가변강성 형 안전관절의 설계)

  • Jeong, Jae-Jin;Chang, Seung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.128-134
    • /
    • 2009
  • This paper aims to design a variable-stiffness type economical safety joint for service robots. The safety joint was designed to have a passive shock absorbing mechanism for protecting human from a catastrophic collision under service condition of robots. A simple mechanism composed of two action disks for switching the load transfer, a spring and a screw for pre-load was proposed. In order to evaluate the performance of the safety joint a testing platform which can carry out the static and impact tests was also designed and fabricated. From the test results, the designed safety joint was proved to have a variable load-carrying capacity and about 42% impact absorption capacity with simple manipulation of the control screw.

The Knowledge Transfer Network and Performance of Chinese Subsidiary in Korean MNCs : Focusing on Roles of Absorptive Capacity and Entry Mode (한국 다국적기업의 중국 자회사의 지식이전, 네트워크와 경영성과에 관한 연구 - 흡수능력과 진입방식의 역할을 중심으로 -)

  • Yoon, Ki-Chang
    • Korea Trade Review
    • /
    • v.41 no.5
    • /
    • pp.325-351
    • /
    • 2016
  • This study empirically investigated the relationship among knowledge transfer, network(firm network and government network) and performance Korean MNCs' subsidiaries in terms of absorptive capacity and entry mode roles in China. For this, absorptive capacity was established as an independent variable, mediating variable, and moderating variable. And the entry mode was divided into single investment and joint venture and set to the moderating variable. Data for the analysis of actual proof was randomly selected from the companies which was established more than 3 years before KOTRA 'The overseas expansion Korean company directory (2014)'. Questionnaires to 138 Chinese subsidiaries of Korean MNCs were collected by FAX and E-mail. AMOS was utilized and collected data investigated the role of the absorption capacity and entry mode as the covariance structure analysis. The empirical analysis showed that absorption capacity has a direct influence on management performance as an independent variable with the network (firm network and government network). It only has a partial mediating role between enterprise networks and management performance, and no meaningful result was gained as its moderationg role bewteen the exogenous variable and management performance. And in terms of Korean companies' moderating role in entering China, they have a moderating role between government network, absorption capacity and management performance, but did not show a statistically significant result between knowledge transfer, enterprise network and management performance. Absorption capacity, as the variable affecting overseas subsidiary's management performance, should not be considered a mediating or moderating variable, but an independent variable. Since the joint venture is showing higher performance than single investment when going into the Chinese market, implication is provided for options in overseas expansion. But this research has the limitation in generalization because it is aiming at the subsidiaries of the Korean company investing in China. Therefore, it is more desirable in the future to conduct a study of the subsidiary of the Korean company entering several countries. It also has limitations in generalization, because the research was conducted using a limited number of variables, despite there are various factors affecting the management performance of Chinese subsidiaries.

  • PDF

Stress Change Varying with Hole Place of RC Column (유공위치 변경에 따른 RC기둥의 내력변화에 관한 실험적 연구)

  • Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.70-79
    • /
    • 2006
  • many plumbing system are needed in the ceiling of the building as it becomes advanced more and more. This leads to make effective space between ceiling level and slab less. Also, piping system is not suitably arranged and operated if it is bent around the columns which they are a lot. But this system can be more effective if it passes through the columns directly. Most people think that those columns should not be damaged with such as holes. But actually this is existed in a hotel building in switzerland. This study is to fing out how much capacity the columns become damaged and low using model size of $20cm{\times}30cm$ rectangular section, and 160cm long, in the structural test. it's compressive strength is focused on $240kg/cm^{2}$ design strength, commonly used in korea. Compressive test for them was done at Hanyang University using UTM one thousand tone(1000t) capacity. Variable numbers for the study are one hole of dia 3cm with distance 20cm or 40cm, two holes of dia 3cm with 20cm and 40cm distance, one hole of dia 5cm with distance 20cm and 40cm, two holes of dia 5cm with 20cm and 40cm distance, me eccentric hole with 20cm and 40cm distance, Normal(without hole). two test specimens of each variable are made for the test. ED5H20 capacity was 16.7% decreased, compared to normal one. While ED5H40 distant 40cm from the end of column top showed 19.5% capacity decrease, compared to normal one. Strain of ED5H20 diameter 5cm, in distance of 20cm form the top of the column was less 5% than the one of diameter 3cm. Finally, conclusions are that in case of hole diameter 3cm, located at 20cm from the end of the column top, capacity was decreased down to 3, percent only compared to the same diameter hole with 20cm distant from the end of it.