• Title/Summary/Keyword: van Laar and Wilson equations

Search Result 13, Processing Time 0.022 seconds

The Lower Flash Points of the n-Butanol+n-Decane System

  • Dong-Myeong Ha;Yong-Chan Choi;Sung-Jin Lee
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.50-55
    • /
    • 2003
  • The lower flash points for the binary system, n-butanol+n-decane, were measured by Pensky-Martens closed cup tester. The experimental results showed the minimum in the flash point versus composition curve. The experimental data were compared with the values calculated by the reduced model under an ideal solution assumption and the flash point-prediction models based on the Van Laar and Wilson equations. The predictive curve based upon the reduced model deviated form the experimental data for this system. The experimental results were in good agreement with the predictive curves, which use the Van Laar and Wilson equations to estimate activity coefficients. However, the predictive curve of the flash point prediction model based on the Willson equation described the experimentally-derived data more effectively than that of the flash point prediction model based on the Van Laar equation.

The Measurement of Minimum Flash Point Behaviour (MFPB) for Binary Mixtures (이성분계 혼합물의 최소인화점 현상의 측정)

  • Hong, Soon-Kang;Yoon, Myung-O;Lee, Sung-Jin;Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • The flash point is an important indicator of the flammability of a chemical. The minimum flash point behaviour (MFPB) is exhibited when the flash point of a mixture is below the flash points of the individual components. The identification of this behaviour is critical, because a hazardous situation results from taking the lowest component flash point value as the mixture flash point. In this study, the flash points for the n-butanol + n-decane and n-octane + n-propanol systems which exhibit MFPB, were measured by Tag open-cup apparatus. The experimental data were compared with the alues calculated by the Raoult's law, the van Laar equation and the Wilson equation. The calculated values based on the van Laar and Wilson equations were found to be better than those based on the Raoult's law. It was concluded that the van Laar and Wilson equations were more effective than the Raoult' law at describing the activity coefficients for non-ideal solution such as the n-butanol + n-decane and n-octane + n-propanol systems. The predictive curve of the flash point prediction model based on the Wilson equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the van Laar equation.

The Measurement and Estimation of Lower Flash Point for o-Xylene+n-Pentanol and m-Xylene+n-Hexanol Systems Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 o-Xylene+n-Pentanol 계와 m-Xylene+n-Hexanol 계의 하부인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin;Jeong, Kee-Sin
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.19-25
    • /
    • 2010
  • The flash points for the systems, o-xylene+n-pentanol and m-xylene+n-hexanol, were measured by using Tag open-cup tester(ASTM D1310-86). The experimental data were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law. The predictive curve of the flash point prediction model based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the Wilson equation.

Measurement and Prediction of the Flash Points and the Fire Points for the Flammable Binary Mixtures Using Open-cup Apparatus (개방식 장치를 이용한 가연성 2 성분계 혼합물의 인화점 및 연소점 측정 및 예측)

  • Ha, Doo-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.47-52
    • /
    • 2007
  • The flash points and the fire points for the m-xylene+n-propionic acid and n-butanol+n-pentanol systems were measured by using Tag open-cup apparatus(AS1M D 1310-86). The experimental flash points of two binary systems were compared with the values calculated by the Raoult's law, Van Laar equation and Wilson equation. The calculated values based on the Raoult's law on m-xylene+n-propionic acid system were found to be better than those based on Van Laar and Wilson equations. The calculated values based on Van Laar equation on n-butanol+n-pentanol system were found to be better than those based on the Raoult's law and Wilson equation. The the fire points for the m-xylene+n-propionic acid system were about $7{\sim}8^{\circ}C$ above the flash points. In the case of n-butanol+n-pentanol system, the flash points and the fire points had been found to be identical.

The Prediction of Lower Flash Points by Optimization Method

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.15-19
    • /
    • 2009
  • The flash point is the most widely used flammability property for the evaluation of the flammability hazard of combustible liquid mixtures. In this paper, the reported flash points for the the binary systems, ethylbenzene+n-butanol and ethylbenzene+n-hexanol were correlated by the optimization method. The optimization method based on the van Laar and Wilson equations were compared with the Raoult's law. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

The Measurement and Prediction of Maximum Flash Point Behavior for Binary Solution (이성분계 용액의 최대인화점 현상의 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.70-74
    • /
    • 2013
  • The flash point is one of the most important physical properties to charaterize fire and explosion hazard of liquid solutions. The maximum flash point of liquid mixture is larger than those of the individual components. In this study, the flash points of 2-pentanol+acetic acid system were measured by Seta flash closed cup tester. This system exhibited the maximum flash point behavior. The flash points were estimated by the Raoult's law and the optimization methods using the van Laar and Wilson equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

Prediction of Lower Explosion Limits of Binary Liquid Mixtures by Means of Solution Thermodynamics (용액열역학에 의한 2성분계 혼합물의 폭발하한계 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.5
    • /
    • pp.20-25
    • /
    • 2009
  • Low explosion limits of flammable liquid mixtures can be calculated with the appropriate use of the fundamental laws of Raoult, Dalton, Le Chatelier and activity coefficient models. In this paper, Raoult's law, van Laar equation and Wilson equation are shown to be applicable for the prediction of the lower explosion limits for ethylacetate+ethanol and ethanol+toluene systems. The calculated values based on Raoult's law were found to be better than those based on van Laar and Wilson equations.

  • PDF

Measurement and Prediction of Flash Points of Acetic Acid-Formic Acid System using Cleveland Open Cup Apparatus (Cleveland 개방식 장치를 이용한 Acetic acid+Formic acid 계의 인화점 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.67-72
    • /
    • 2013
  • The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. The flash point is a major physical property used to analyse the fire and explosion hazards of a flammable liquid solution. The flash point data for pure components are easily available in several literature. But the flash points of the flammable binary solutions appear to be scarce in the literature. The objective of this study is to measure and estimate the flash point of acetic acid-formic acid system. Cleveland open cup tester was used to measure the flash point. The experimental data were compared with the values estimated by the Raoult's law and the optimization methods based on van Laar and Wilson equations. As a result, the estmated values by optimization methods were found to be better than those based on the Raoult's law.

Flash Points of the Binary Solutions Using Cleveland Open Cup Tester (클리브랜드 개방식 장치를 이용한 2성분계의 인화점)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.57-62
    • /
    • 2011
  • The flash point is one of the most significant combustion properties of flammable liquids in industrial processes when evaluation process safety, In this paper, Cleveland open cup tester is used to measure the flash points for the two binary systems (n-propanol + formic acid and acetic acid + propionic acid). The measured flash points were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

Isobaric vapor-liquid equilibria for ternary and each corresponding binaries of the system n.Dodecane-1.Decanol-1.Dodecanol at 15 mbar (n.Dodecane-1.Decanol-1.Dodecanol 삼성분계 및 각 이성분계의 15 mbar 정합 기액평형)

  • 박소진;이태종
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.308-314
    • /
    • 1993
  • Both Vapor-liquid equilibrium data and boiling temperature have been measured for ternary and each corresponding binaries of n.dodecane-1.decanol-1.dodecanol mixture under constant pressure of 15 mbar. Measured vapor-liquid equilibrium data were correlated with the conventional g$\^$E/ model ; Margules, van Laar, Wilson, NRTL and UNIQUAC equations. Binary equilibrium data were thermodynamically tested by Redlich-Kister integral method and ternary data were also qualitatively checked by two point consistency test, suggested by McDermott-Ellis. Among the binary VLE data, only the system n.dodecane-1.decanol has minimum boiling azeotrope.

  • PDF