Flash Points of the Binary Solutions Using Cleveland Open Cup Tester

클리브랜드 개방식 장치를 이용한 2성분계의 인화점

  • 하동명 (세명대학교 보건안전공학과) ;
  • 이성진 (세명대학교 임상병리학과)
  • Received : 2010.12.09
  • Accepted : 2011.02.11
  • Published : 2011.02.28

Abstract

The flash point is one of the most significant combustion properties of flammable liquids in industrial processes when evaluation process safety, In this paper, Cleveland open cup tester is used to measure the flash points for the two binary systems (n-propanol + formic acid and acetic acid + propionic acid). The measured flash points were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

인화점은 공정안전을 평가할 때 산업공정에서 가연성 액체의 중요한 연소 특성 가운데 하나이다. 본 연구에서는 클리브랜드 개방식 장치를 사용하여 n-propanol + formic acid계와 acetic acid + propionic acid계의 인화점을 측정하였다. 실험값은 Raoult의 법칙과 최적화 기법에 의해 추산된 값과 비교하였다. 그 결과, 최적화 기법에 의한 추산값이 Raoult의 법칙에 의한 추산값 보다 실험값에 더욱 근접하였다.

Keywords

References

  1. F. Gharagheizi and R.F. Alamdari, "Prediction of Flash Point Temperature of Pure Components Using a Quantitative Structure-Property Relationship Model", QSAR. Comb. Sci., Vol.27, pp.679-683(2008). https://doi.org/10.1002/qsar.200730110
  2. J.A. Lazzus, "Prediction of Flash Point Temperature of Organic Compounds Using a Hybrid Method of Group Contribution + Neural Network + Particle Swarm Optimizaion", Chinese Journal of Chem. Eng., Vol.18, No.5, pp.817-823(2010). https://doi.org/10.1016/S1004-9541(09)60133-6
  3. J. Taskinen and J. Yliruusi, "Prediction of Physicochemical Properties Based on Neural Network Modeling", Adv. Drug Deliv. Rev., Vol.55, pp.1163-1183(2003) https://doi.org/10.1016/S0169-409X(03)00117-0
  4. J.G. Walsham, "Prediction of Flash Points for Solvent Mixtures", Advances in Chemistry Series, Publ. 73, Ser. 124, Washington, DC, pp.56-69(1973).
  5. W.A. Affens and G.W. McLaren, "Flammability Properties of Hydrocarbon Solutions in Air", J. Chem. Eng. Data, Vol.17, No.4, pp.482-488(1972). https://doi.org/10.1021/je60055a040
  6. D. White, C.L. Beyler, C. Fulper, and J. Leonard, "Flame Spread on Aviation Fuels", Fire Safety Journal, Vol.38, pp.1-31(1997).
  7. S.J. Lee and D.M. Ha, "The Lower Flash Points of Binary Systems Containing Non-flammable Component", Korean J. Chem. Eng., Vol.20, No.5, pp.799-802(2003). https://doi.org/10.1007/BF02697279
  8. H.J. Liaw, Y.H. Lee, C.L. Tang, H.H. Hsu, and J.H. Liu, "A Mathematical Model for Predicting the Flash Point of Binary Solutions", J. of Loss Prevention in the Process Industries, Vol.15, pp.429-438(2002). https://doi.org/10.1016/S0950-4230(02)00068-2
  9. M. Vidal, W.J. Rogers, and M.S. Mannan, "Prediction of Minimum Flash Point Behaviour for Binary Mixtures", Process Safety and Environmental Protection, Vol.84(B1), pp.1-9(2006).
  10. S.Y. Kim and B.S. Lee, "A Prediction Model for the Flash Point of Binary Liquid Mixtures", J. of Loss Prevention in the Process Industries, Vol.23, pp.166-169(2010). https://doi.org/10.1016/j.jlp.2009.07.008
  11. B.E. Poling, J.M. Prausnitz, and J.P. O'connell, "The Properties of Gases and Liquids", 5th Edition., McGraw-Hill, New York(2001).
  12. H. Le Chatelier, "Esimation of Firedamp by Flammability Limits", Ann. Minmes, Vol.19, 388(1891).
  13. J. Gmehing, U. Onken, and W. Arlt, "Vapor-Liquid Equilibrium Data Collection", 1, Part 1-Part 7, DECHEMA(1980).
  14. D.M. Ha and S.J. Lee, "Estimation of the Flash Points for n-Propanol + Formic Acid System Using the Binary Parameters Optimization Method", J. of Korea Institute of Fire Sci. & Eng., Vol.22, pp.65-69(2008).
  15. J.L. Kuester and J.H. Mize, "Optimization Techniques with Fortran", McGraw-Hill, NewYork(1973).
  16. D.M. Ha and S.J. Lee, "The Measurement and Estimation of the Lower Flash Points for tert-Pentanol + Propionic Acid and p-Xylene + Propionic Acid Systems Using Open-Cup Apparatus", J. of Korea Institute of Fire Sci. & Eng., Vol.23, No.5, pp.161-166(2009).