• Title/Summary/Keyword: valve stem

Search Result 64, Processing Time 0.028 seconds

Experimental Study on the Oil Leakage Characteristics of Valve Stem System (밸브 스템계의 누유특성에 관한 실험적 연구)

  • 이일권;김청균
    • Tribology and Lubricants
    • /
    • v.20 no.4
    • /
    • pp.204-208
    • /
    • 2004
  • This paper presents the oil leakage characteristics of the valve stem system in gasoline engines. For the oil leakage investigation, four study models have been prepared as functions of used poppet valve and used valve stem seal, used poppet valve and unused valve stem seal, unused poppet valve and used valve stem seal, and unused poppet valve and unused valve stem seal. With four models, the experimental study on the oil leakage has been investigated for the oil temperature, intake pressure, and camshaft speed. The experimental results show that the sealing performance of the valve stem seal plays an important role on the leakage of the valve stem system. And the appropriate replacement of a stem seal with used poppet valve shows good sealing performance in oil leakage in compared with a new valve system.

Surface Roughness Effects of a Valve Stem on the Leakage Characteristics in LPG Automotive (LPG자동차에서 밸브스템 표면거칠기가 누유특성에 미치는 영향에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • This paper provides the effects on the leakage characteristics of the surface roughness of a valve stem in LPG automotive. The valve stem seal is to stop an oil leakage through a sealing gap between a valve stem and a valve stem seal. The sealing performance of two components is related to a leak safety and a long life of a valve stem and a valve stem seal. The experimental results show that the optimal surface roughness of a valve stem is to recommend as $0.4{\sim}0.5{\mu}m$ in a centerline average roughness, Ra and a uniformly distributed profile of the roughness. Basically the smooth surface and uniform profiles of the roughness may reduce an oil leakage between a valve stem and a valve stem seal.

  • PDF

A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve (모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구)

  • Kim, Dae-Woong;Yoo, Seong-Yeon;Park, Sung-Keun;Lee, Do-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

Transient analysis of lubrication with a squeeze film effect due to the loading rate at the interface of a motor operated valve assembly in nuclear power plants

  • Jaehyung Kim;Sang Hyuk Lee;Sang Kyo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2905-2918
    • /
    • 2023
  • The valve assembly used in nuclear power plants is important safety-related equipment. In the new standard, the physical attributes are measured using a valve diagnosis test, which is used in the expansion to other non-tested valves using a quantitative test-basis methodology. With a motor-operated actuator, the state of stem's lubrication is related to physical attributes such as the stem factor and the friction coefficient. This study analyzed the numerical transient of fluid and solid lubrication with a squeeze film effect due to the loading rate on the stem and the stem nut using the experimental data. The differential equation that governs the motion mechanism of the stem and stem nut is established and analyzed. The flow rate, the fluid and the solid contact forces are calculated with the friction coefficient. Finally, we found that a change in the friction coefficient results from a change of the shear force in the solid contact mode during the interchange process between the solid contact mode and the fluid contact mode. The qualitative understanding of the squeeze film effect is expanded quantitatively for forces, thread surface distance, velocity, and acceleration, with consideration of the metal solid contact and fluid contact.

Diagnosis for damage of fire hydrant with long valve stem in power plant. (발전소내 긴 밸브 stem을 갖는 옥외 소화전의 파손 현상 규명)

  • Sohn, Seok-Man;Lee, Sang-Guk;Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Ki-Tae
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3512-3517
    • /
    • 2007
  • Nuclear power plant has many external fire hydrants that have to operate in the state of emergency such as facility fire, forest fire. The valve stem of one among them was broken 3 times for 4 years. It had long valve stem and operated under high water pressure. The elongation and the tensile strength for the broken valve stem was measured to examine the defect of material property. And the vibration level and the natural frequencies was detected to check the resonance. As the result of a diagnosis, the cause of this fault is proven buckling of long valve stem.

  • PDF

Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve (차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향)

  • Kim, Dae-Woong;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.

A Study for the Improvement Method of Flexible Wedge Gate Valve Operation Capability (Flexible Wedge Gate 밸브의 운전 성능향상 방안에 관한 연구)

  • Kim, Dae-Woong;Lee, Do-Hwan;Kang, Sin-Chul;Kim, In-Whan;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.644-651
    • /
    • 2001
  • The purpose of this study is to develop the improvement method of MOV(Motor Operated Valve) operability without major modification or change of MOV which needs a great expense and manpower. We studied valve stem lubrication, stem packing thrust and actuator control switch which could give an major effect to MOV operability, and found the some consequences. First, the stem/stem-nut friction coefficient and stem factor is significantly effected by stem lubrication state. Second, the measured packing thrust value is appeared higer than the design value for tested valves and the preparation of optimal value selection criteria is needed. Finally, optimization of MOV control switch is another major factor for MOV operability and structual integrity.

  • PDF

A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition (고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Yoo, S.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

A Method of ROL Improvement for the Motor Operated Gate Valve Operating in the High Differential Pressure Condition (고차압에서 운전되는 모터구동게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Park, S.G.;Hong, S.Y.;Yooh, S.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.562-567
    • /
    • 2003
  • This paper presents the method of Rate of Loading(ROL) improvement for the Motor Operated Gate Valve operating in high differential pressure condition. The character of ROL and Stem Factor is analyzed. Static test and dynamic test were performed and acquired the diagnosis signal for the valve closing stroke. The result of this study is the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of dynamic test thread friction coefficient stem and stem nut should be combined appropriately.

  • PDF