• 제목/요약/키워드: valve position

검색결과 385건 처리시간 0.02초

이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구 (An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart)

  • 조영호;최원우
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

급발진 사고원인을 증명하기 위한 자동차 블랙박스 시스템 개발 (Implement Automobile Black Box System for Proving Cause of Sudden Unintended Acceleration)

  • 김민영;장종욱
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1429-1434
    • /
    • 2014
  • 현재 자동차 급발진 사고가 급증하고 있다. 아직도 정확한 자동차 급발진 원인을 찾지 못해 아무것도 모르는 운전자가 급발진 사고에 대한 아픔을 가지고 모든 책임을 감당하고 있다. 사용자가 이런 문제를 제조사에 제기할 경우 자동차에 설치된 EDR(Event Data Recorder)을 회수해서 제조사 자체적으로 분석해서 알려주지만, 대부분 자동차에서는 문제가 없다고 일축한다. 이런 상황에서 급발진 사고에서 운전자의 신변을 보호를 위한 기술이 개발이 필요하다. 본 논문에서는 자동차 급발진 사고의 여러 원인 중 유력하게 추정되는 스로틀밸브의 문제에서 운전자의 신변을 보호하기 위해 관련 데이터를 추가적으로 수집하는 블랙박스 시스템을 개발하였다.

오리피스 유량계에서 게이지라인 누설에 의한 계량오차 (The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter)

  • 이철구;하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF

선박 에너지 절감을 위한 PCS 시뮬레이터 및 데이터 저장 시스템 개발 (Development of a PCS Simulator and Data Storage System for Energy Saving in the Ship)

  • 오진석;강영민
    • 한국정보통신학회논문지
    • /
    • 제19권9호
    • /
    • pp.2189-2196
    • /
    • 2015
  • 환경오염 및 유류비가 증가함에 따라 선박 에너지 절감 방안에 대한 연구가 활발히 진행되고 있다. PCS(Pump Control System)는 선박냉각시스템에서 해수펌프 회전속도, 청수펌프 회전속도 및 3-Way V/V 위치 제어를 통해 에너지를 절감하는 펌프제어시스템이다. 본 논문에서는 PCS의 신뢰성 확보를 위해 실 선박의 냉각시스템과 유사한 환경을 갖춘 PCS 시뮬레이터를 개발하였다. 또한 PCS 시뮬레이터를 위한 컴퓨터 기반의 제어 시스템 및 데이터 저장시스템을 개발하였다. 제어 및 데이터 저장시스템 개발에는 National Instrument 사의 cDAQ 및 LabVIEW를 사용하였다. 최종적으로 저장된 데이터를 분석하여 시뮬레이터의 동작을 확인하였다.

The study of environmental monitoring by science airship and high accuracy digital multi-spectral camera

  • Choi, Chul-Uong;Kim, Young-Seop;Nam, Kwang-Woo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.750-750
    • /
    • 2002
  • The Airship PKNU is a roughly 12 m (32 ft) long blimp, filled with helium, whose two-gasoline power(3hp per engine) are independently radio controlled. The motors and propellers can be tilted and are attached to the gondola through an axle and supporting braces. Four stabilizing fins are mounted at the tail of the airship. To fill in the helium, a valve is placed at the bottom of the hull. The inaugural flight was on jul. 31.2002 at the Pusan, S.korea Most environment monitoring system\ problem use satellite image. But, Low resolution satellite image (multi-spectral) : 1km ∼ 250 m ground resolutions is lows. So, detail information acquisition is hard at the complex terrain. High resolution satellite image (black and white) 30m : The ground resolution is high. But it is high price, visit cycle and delivery time is long So. We want make high accuracy airship photogrammetry system. This airship can catch picture Multi. spectral Aerial photographing (visible, Near infrared and thermal infrared), and High resolution (over 6million pixel). It can take atmosphere datum (Temperature (wet bulb, dew point, general), Pressure (static, dynamic), Humidity, wind speed). this airship is very Quickness that aircraft install time is lower than 30 minutes, it is compact and that conveyance is easy. High-capacity save image (628 cut per 1time (over 6million and 4band(R,G,B,NIR)) and this airship can save datum this High accuracy navigatin (position and rotate angle) by DGPS tech. and Gyro system. this airship will do monitor about red-tide, sea surface temperate, and CH-A, SS and etc.

  • PDF

개심술 180례에 대한 임상적 고찰 (Open Heart Surgery:Clinical Analysis of 180 Cases)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • 제27권6호
    • /
    • pp.460-471
    • /
    • 1994
  • Between Feb. 1990 and Aug. 1993, 180 cases of the open heart surgery were performed under cardiopulmonary bypass in the Department of Thoracic & Cardiovascular surgery, Gil General Hospital. There were 83 cases with congenital heart diseases [CHD] and 97 cases with acquired heart diseases [AHD]. The CHD consisted of 78 acyanotic[mortality: 3.8 %] and 5 cyanotic cases with heart anomaly[mortality:l case]. The AHD were 97 cases, which contained 53 valvular, 27 ischemic heart diseases, 10 aortic diseases, 5 cases with myxoma, 1 case with post-infarct VSD, and 1 case with removal of infected pacing wire in right ventricle. In the 53 valvular heart diseases, there were 45 cases with valve replacement[MVR 27, AVR 9,MVR + AVR 9] and 8 cases with valvuloplasty. The number of the implanted prosthetic valves were 53. In MVR, 25 St. Jude, 6 Sorin, 3 Carpentier-Edward and 2 Intact medical valves were used. In aortic position, 13 St. Jude, 3 Sorin and 1 Intact medical valves were applied. The operative mortality was 5.6 % [3/53]. The annuloplasty applying artificial ring was performed in 17 patients[4 cases associated with MVR] and the number of the implanted ring was 19, which included 14 Duran ring[10 mitral, 4 tricuspid] and 5 Carpentier ring [3 mitral, 22 tricuspid]. In the 27 ischemic heart diseases, there were 9 cases with left main coronary artery lesions, 7 one vessel, 5 two vessels, and 6 three vessels. Average number of anastomosis was 2.8 per patient. The operative mortality was 14.3 % [4/27]. Among the 10 patients with aortic diseases, 7 cases were aortic dissection[type A: 5, type B: 2] and 3 cases were descending thoracic aortic aneurysm. The operative morality occurred in 3 cases. The overall mortality and the operative mortality of congenital and acquired heart disease was 7.8 %, 4.8% and 10.4%, respectively.

  • PDF

Phylogenetic position of eight Amphora sensu lato (Bacillariophyceae) species and comparative analysis of morphological characteristics

  • Wang, Pengbin;Park, Bum Soo;Kim, Jin Ho;Kim, Joo-Hwan;Lee, Hae-Ok;Han, Myung-Soo
    • ALGAE
    • /
    • 제29권2호
    • /
    • pp.57-73
    • /
    • 2014
  • Amphora Ehrenberg ex Kutzing sensu lato is a common and widespread benthic diatom genus with a taxonomy that has been under continual revision, particularly based on molecular analyses. Although Amphora species have been studied using modern microscopy in recent years, there has not been much progress on molecular characterization of the species, especially in Asia. In this study of Amphora, sampling was carried out from September 2009 to August 2010 in Korean coastal waters. The morphological and molecular characteristics of eight Amphora sensu lato were examined: Amphora marina, A. proteus, Halamphora costata, H. coffeaeformis, H. eunotia, H. holsatica, H. terroris, and Halamphora sp. Based on previous accounts, morphology suggested that A. marina and A. proteus belong to the subgenus Amphora Cleve, which have smooth girdle bands and rather coarse and very distinct areolae on the valve. The other species, H. coffeaeformis, H. costata, H. eunotia, H. holsatica, H. terroris, and Halamphora sp. belong to the subgenus Halamphora Cleve, which was recently elevated to generic status by Levkov 2009, have plicate girdle bands, puncta which do not form straight longitudinal lines, valves which have a narrow ventral portion and apices that are generally rostrate-capitate and recurved. In agreement with analysis based on morphological characteristics, phylogenetic analysis based on small subunit rDNA suggested that the eight Amphora sensu lato species were not a monophyletic group as the morphological classification. Also, the results of molecular work and statistical analysis on all these Amphora sensu lato combined with phylogenic analysis on our geographically representative samples give strong evidence that Halamphora Levkov is independent of Amphora Cleve. Furthermore, in this study, Amphora terroris was transferred Halamphora as Halamphora terroris (Ehrenberg) Wang comb. nov. and Amphora marina was recorded for the first time in Korea.

감염성 심내막염의 임상적 고찰 (Clinical Analysis of Infective Endocarditis)

  • 김혁;김영학;정원상;신경욱;김지훈
    • Journal of Chest Surgery
    • /
    • 제43권6호
    • /
    • pp.619-626
    • /
    • 2010
  • 배경: 감염성 심내막염의 수술 적응증 및 시기 등은 논란의 대상이다. 저자들은 본 교실에서 최근 10년간 연속적으로 수술받은 감염성 성내막염 환자들에 대한 수술 결과를 분석하여 적절한 수술 적응증 및 시기 등에 대해 문헌 고찰과 함께 보고하고자 한다. 대상 및 방법: 2000년 1월부터 2009년 12월까지 본원에서 연속적으로 수술한 감염성 심내막염 환자 23예를 후향적으로 분석하였다. 진단은 modified Duke criteria에 준하였고 남녀 비율 2.8:1, 평균연령 $46.78{\pm}16.19$ (24~76)세, NYHA 기능 분류상 class I 1예(4.3%), class II 4예 (17.4%), class III 10예(43.5%), class IV 8예(34.8%)였다. 수술 전 혈액내 균 배양 검사에서 8예 (34.8%)가 원인균이 동정되었고 수술 전 평균 항생제 사용기간은 $20.78{\pm}16.00$ (1~56)일이었다. ACC/AHA 심장판막질환 지침중 감염성 심내막염의 수술 적응증에 근거하여 수술을 진행하였으며 12예(52.2%)에서 긴급 수술이 필요하였다. 23명의 환자 모두 외래 추적 관찰이 가능하였으며 평균 외래 추적 관찰 기간은 $49.26{\pm}33.21$ (11~128)개월이었다. 결과: 수술 소견상 우종은 20예에서 발견되었고 대동맥판막 치환술 9예, 승모판막 치환술 8예, 승모판막 성형술 1예, 대동맥판막 치환술과 승모판막 치환술을 함께 시행한 3예가 있었다. 승모판막 성형술 l예를 제외한 20예의 판막치환술 환자 중 19예에서 기계판막을 사용하였다. 감염된 점액종의 제거술이 1예, 감염된 심박동기 lead의 제거술 및 감염조직 절제술이 1예였다. 수술 후 평균 항생제 투여 기간은 $24.39{\pm}15.98$ (l2~85) 일이었다. 수술 후 합병증은 출혈로 재수술한 2예, 심낭막절개술 후 증후군으로 배액술이 필요했던 l예, 수술장에서 발생한 저심박출증 l예, 수술 후 일과성 뇌 허혈증이 있었던 l예 등이었다. 수술 전후로 비교한 NYHA 기능분류는 통계적으로 유의한 개선이 있었고(p<0.001) 평균 좌심실 구현률은 유의하지 않았으며(p=0.468) 좌심실 이완기말/수축기말 크기, 좌심방 크기는 유의한 개선이 있었다(p<0.05). 결론: 감염성 심내막염 환자에서 적절한 수술 적응증을 적용하여 조기수술을 필요로 하는 환자에서는 적시에 수술을 시행하였으며 혈류역학적으로 안정된 경우는 충분한 항생제 투여로 전신성 염증의 소설을 유도한 후 수술을 시행하여 전 예에서 수술 사망이나 감염의 재발없이 좋은 단중기 수술 성적을 얻을 수 있었다.

우심실 유출로에 사용된 냉동 동종 판막도관의 중기성적 (Mid-term Follow-Up Results of Cryopreserved Valved Conduit in RVOT Reconstruction)

  • 장윤희;전태국;민호기;한일용;성기익;이영탁;박계현;박표원
    • Journal of Chest Surgery
    • /
    • 제36권6호
    • /
    • pp.384-390
    • /
    • 2003
  • 1966년 Ross와 Sommerville에 의해서 폐동맥 판 폐쇄 환자의 우심실 유출로 재건에 동종 대동맥 판막 도관 이 처음으로 이식되어 보고된 이후 최근까지 다양한 복잡 선천성 심장기형의 완전 교정술에 꾸준히 사용되어 오고 있다. 이렇게 축적된 경험에 힘입어, 국내에서도 여러 병원에서 적극적으로 사용하고 있지만 아직 임상 경험 및 결과에 대한 국내의 보고가 드물어 본원의 경험을 공유하고자 한다. 대상 및 방법: 1996년 1월부터 2001년 12월까지 우심실 유출로에 심장 외 판막 도관(extra-valved conduit)으로 동종이식편을 사용한 예가 27예 있었는데, 이들 중 1년 이상 추적 관찰이 가능한 22명의 환자들을 대상으로 하였다. 환자의 연령의 중앙값은 16개월(9일~18세)이었다. 수술시 진단은 심실 중격 결손에 폐동맥 판막 폐쇄가 동반 된 환자가 13예로 가장 많았고, 그밖에 총 동맥간 3예, 대 혈관 전위증 혹은 수정 대 혈관 전위증에 우심실 유출로의 폐쇄가 동반된 예가 각각 3예씩 있었다. 이식 편의 크기는 15~26 mm로 다양하였으며, 평균 18$\pm$3.82 mm였다. 추적 관찰 기간의 중앙값은 48개월(기간 12~80.4개월)이었다. 결과: 이식 편 자체의 변성으로 인한 재수술은 없었으나, 말단 폐동맥의 협착으로 인한 이식 도관의 비정상적 확장 및 폐동맥 판막의 역류, 우심실의 기능부전으로 이식 도관의 교체가 필요했던 환자가 1명 있었다. 추적 관찰 시 시행한 심초음파상, 유의한 폐동맥 판막의 협착을 보인 환자가 1명 있었고 폐동맥 판막의 역류가 관찰된 환자가 3명 있었는데, 각각 3~6개월, 1년, 2년에 중등도 이상으로 진행하였다. 그리고, 2명의 환자에서 문합 부분의 경미한 석회화가 관찰되었는데, 모두 대동맥 판막 도관을 이식 받은 환자였다. 결론: 성인과 달리, 소아에서의 우심실 유출로의 재건에 있어서는 아직은 이상적인 대치물이 없다. 본원에서는 초저온 냉동 보관한 동종 판막 도관을 적극적으로 사용하여, 중, 단기 추적 관찰상 비교적 좋은 결과를 보이고 있다. 하지만 향후 동종이식편의 수명에 관련되는 요인들에 대한 면밀한 연구를 통하여, 동종이식편의 채취 및 보관, 사용 등에 대한 기준을 재정립하는 것이 중요할 것이다.

Ross 술식의 중단기 성적 (Mid-term Results of the Ross Procedure)

  • 강성식;정성호;이상권;주석중;송현;송명근;이재원
    • Journal of Chest Surgery
    • /
    • 제38권1호
    • /
    • pp.23-28
    • /
    • 2005
  • Ross 술식은 항응고제의 사용이 필요 없으며, 혈역학적으로 우수하고 내구성이 좋아 대동맥판막 치환술의 이상적인 방법으로 생각되고 있다. 이에 저자들은 본원에서 시행된 Ross 술식의 결과를 조사하여 중-단기 성적을 알아보고자 하였다. 대상 및 방법: 본원에서 1999년 1월부터 2001년 10월까지 Ross 술식을 시행 받은 22명을 대상으로 후향적으로 조사하였다. 환자의 평균 나이는 $30.9{\pm}8.1$$(17\~44)$였고, 수술 전 진단은 대동맥 판막 폐쇄부전증이 20명, 협착증과 부전증이 동반된 경우가 2명이었다. 평균 추적관찰 기간은 $38.9{\pm}1.6$개월이었고, 추적 관찰률은 $100{\%}$였다. 결과: 수술 사망은 없었고, 만기 사망은 2명이었는데 심장질환과 관련된 사망은 1명, 나머지 1명은 다른 원인이었다. 수술과 관련된 생존율은 40.6개월에 $94.1{\pm}5.7{\%}$를 보였다. 수술의 합병증으로는 출혈이 2명, 저심박출증이 3명 있었다. 자가 폐동맥 판막의 이식방법은 근위부 치환술이 14예, inclusion technique이 8예였다. 폐동맥 판막 치환술은 모두 동종 페동맥판막을 이용하였다. 추적 관찰하는 과정에서 중증도 이상의 대동맥 판막 폐쇄 부전증 환자는 없었다. 결론: 본원의 연구 결과 Ross술식의 수술 사망률이나 이환률은 좋은 성적을 보였으나 신대동맥 판막과 폐동맥 동종 판막에 대해서는 앞으로 장기적인 관찰이 필요할 것으로 생각된다.