• Title/Summary/Keyword: valve position

검색결과 386건 처리시간 0.028초

공조용 로터리 압축기의 소음 저감에 관한 연구 (A Study on Noise Reduction of Rotary Compressor)

  • 안병하;김영수
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.60-69
    • /
    • 1999
  • The noise and vibration sources of rotary compressor for room air-conditioner are pressure pulsation of compression process, cavity resonance of inner space, structural radiation noise of shell and impact noise of discharge valve. Among them, pressure pulsation is very important noise and vibration source. Because it transferred various kinds of noise and vibration like as mentioned above. In this reason, muffler and resonator are used in order to absorb and remove these noises. But an analytical prediction using acoustic analysis does not coincident with the experimental result. The difference between analysis and actual state is due to the assumption of analysis. This paper covered with new concept of muffler design based on the turbulence kinetic energy of flow by using CFD. From this analysis, it is possible to decide the best position of discharge port of muffler. Therefore $2{\sim}3dB$ noise reduction effect is acquired in rotary compressor of 5000 BTU grade. Also new approach of resonator design is suggested. From this study, the characteristics of resonator and surge hole (a kind of resonator without pipe length) are identified. The former is useful for pure tone noise (narrow frequency band), and the latter is effective for broad frequency band. This paper shows that it is very available to use 3 dimensional analysis of resonator in order to predict more exact tuning frequency. The result is proved by a lot of experiments. From combination of fluid analysis and acoustic analysis, up stream position is effective location of resonator concerning turbulence motion of fluid.

  • PDF

조수간만의 차를 고려한 새로운 하역 시스템의 능동 제어 (Active Control of a New Cargo Handling System Adapted for Time-Varying Tide)

  • 김형석;정달도;최승복;이재욱
    • 대한조선학회논문집
    • /
    • 제36권2호
    • /
    • pp.61-71
    • /
    • 1999
  • 본 연구에서는 조수간만의 차가 큰 항만에 적합한 새로운 하역 시스템을 제안하였다. 새로운 하역 시스템은 기존의 갑문 이용 방식 대신에 일종의 유압 엘리베이터를 사용함으로써 조수간만의 차에 따라 변하는 선박의 높이로 실시간 제어하여 선적 흑은 하역을 하는 방식이다. 한번에 대량의 컨테이너를 처리하기 위해 컨테이너 팔레트 운송타를 도입함으로써 기존 시스템에 비해 시간당 처리능력을 높일 수 있고, 선적 및 하역의 전 과정을 자동화함으로써 작업 효율을 극대화할 수 있도록 하였다. 새로운 하역 시스템의 개념 입증을 위해 소형 하역 시스템 모델을 설계 제작하였다. 제작된 모델은 컨테이너 팔레트 운송차, 플랫폼과 리프트 칼럼의 복합 구조물, 그리고 전용 운반선으로 구성된다. ER(electro-rheological) 밸브-실린더에 의해 구동되는 플랫폼은 조수간만의 차와 과도에 의해 변하는 선박의 높이를 능동적으로 추적 제어하게 된다. 동적 모델성을 통해 플랫폼의 운동 지배 방정식을 도출하였고, 파도 가진으로 인한 선박의 거동 및 조수간만의 차를 모델링하였다. 선적 및 하역의 자동화와 플랫폼의 정확한 위치 제어를 위해 시퀀스 제어기와 PID(proportional-integral-derivative) 위치 제어기가 연계된 제어 시스템을 구성하였다. 컴퓨터 시뮬레이션과 실험을 통해 제안된 하역 시스템의 유용성을 입증하였다.

  • PDF

유리차수 미분을 이용한 위치제어기 구현 (Position Controller Implementation Using the Fractional Order Derivative)

  • 강정욱;전용호
    • 한국전자통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.185-190
    • /
    • 2019
  • 본 연구는 유리차수 미분의 수학적인 방법을 시스템의 응답을 제어하는 제어기에 적용하고자 한다. 일반적인 PID제어기의 라플라스 변환은 s의 정수지수를 갖게 된다. 유리차수의 미분은 라플라스 변환에서 s에 대한 유리수 지수를 갖게 된다. 따라서 이를 제어기로 구성하기 위해서는 유리수 지수에 대한 설계가 적절하지 않아 이산시간으로 변환하여 설계하는 방법을 제안한다. 이를 표준 2차 시스템에 적용하여 성능을 살펴보고, 산업현장에서 많이 사용되는 솔레노이드밸브에 적용한다. 외란 상태의 추정이 가능하도록 루엔버거 관측기를 설계하고 관측된 상태에 대하여 유리차수 제어기를 적용하여 균일하며 정밀한 제어성능을 얻을 수 있었다. 정상상태의 위치오차가 0.1 [%]이내이고, 기동시간이 약 0.3 [s]이내의 정밀하며 균일한 위치제어성능 가짐을 확인할 수 있었다.

반 쐐기형 연소실을 채택한 SI 기관에서 포트형상이 정상유동 특성에 미치는 영향 (2) - 유속분포 (2) (Effects of Port Shape on Steady Flow Characteristics in an SI Engine with Semi-Wedge Combustion Chamber (2) - Velocity Distribution (2))

  • 윤인경;엄인용
    • 대한기계학회논문집B
    • /
    • 제41권2호
    • /
    • pp.97-107
    • /
    • 2017
  • 본 논문은 반 쐐기형 연소실에서 포트형상에 따른 정상유동 특성을 비교한 연구의 두 번째로 유동 평가위치의 영향을 고찰한 것이다. 입자영상유속계로 반 쐐기형 연소실에 직선형 포트와 나선형 포트를 적용하여 측정위치를 헤드 밑면부터 하류로 보어의 1,75배 위치 즉 1.75B부터 6배 위치 즉, 6.00B까지 변경하면서 평면유속을 측정하였다. 속도분포 분석 결과 반 쐐기형 연소실을 채택하면 지붕형과 달리 동일 리프트에서 거시적 유속분포와 유선은 스월 거동 중심은 측정위치가 관계없이 거의 일정하다. 직선형 포트에서는 모든 측정위치에서 편심도는 충격식 스월 측정기에서 측정값 왜곡이 발생하는 범위에 들어오고, 나선형 포트에서도 리프트 4mm 이하에서는 모든 측정위치에서 편심의 영향을 무시할 수 없지만, 측정위치가 3.00B 이상이 되면 리프트 5mm 이상에서 편심도가 급격히 감소한다. ISM가정과의 속도분포 차이에 의해 직선형 포트의 리프트 4mm 이하 스월 중심 평가를 제외하고 모든 PIV 평가방법에서 ISM 평가 대비 상대적인 상쇄효과가 있다. 마지막으로 중심 설정과 축 방향 속도분포 가정은 스월 평가에 정성적 영향을 주지 않고, 구체적인 접선속도 분포형태에 따라 절댓값에만 영향을 준다.

수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교 (Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves)

  • 강준규;홍준화;김형태;박인덕;이철주
    • Journal of Chest Surgery
    • /
    • 제38권7호
    • /
    • pp.496-500
    • /
    • 2005
  • 심장판막질환의 외과적 교정에 사용되는 수종의 기계판막들은 각기의 장점들을 주장하고 있으나, 중장기의 임상적 결과에는 유의한 차이를 보이지 않는다. 기계적 기능의 차이를 단순 비교하기는 어려우나 수술 후에 시행한 초음파심음향도로 측정한 판막간 압력차와 유효개구면적을 비교하여 다양한 기계판막들간의 기능을 비교하고자 한다. 대상 뜻 방법: 1995년부터 2003년 사이에 아주대학교병원 흥부외과에서 기계판막으로 치환술을 받았던 345명의 환자들에 사용되었던 396개의 기계판막을 대상으로 후향적 분석을 하였다. 사용되었던 판막으로는 Sorin Bicarbon, SJM, ATS, On-X, 그리고 Edward MRA로 5종류였다. 판막의 위치는 승모판막이 232개, 대동맥판막이 162, 그리고 삼첨판막이 2개였으며, 이중 다중판막치환술이 51예에서 있었다. 수술 후 14일이 지난 후에 시행한 초음파심음향도에서 유효개구면적, 수축기 평균압력차, 그리고 이완기 평균압력차를 지표로 통계학적인 비교분석을 하였다. 결과: 345명의 대상환자중 남자가 178명, 여자가 167이었고, 평균연령은 남자/여자가 $50.6\pm13.9/52.6\pm14.6$세였다. 승모판막의 경우 27mm에서는 MDPG/EOA가 Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$였으며, 31m에서는 Sorin, SJM, ATS, Mmh가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\p,0.2,\;3.7\pm1.5/2.7\pm0.7$ 였으며, 31mmdptjsms Sorin, SJM, ATS, MIRA가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$였으며, 33 m에서는 Sorin, SJM, MIRA가 $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$이었다. 대동맥판막의 경우 19mm에서 MSPG/EOA가 Sorin, SJM, ATS, On-X, MIRA가 $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$였으며, 21mm에서는 SJM, ATS, On-X, MIRA가 $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$였으며, 23 m에서는 Sorin, SJM, ATS On-X, MIRA가 $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$이었다 25mm에서는 SJM과 MIRA가 $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$이었다. 통계학적인 분석을 한 결과 같은 위치에 같은 크기의 판막들간에는 통계적으로 유의한 차이가 없었다. 판막재치환을 한 경우는 용혈로 인한 재치환이 ATS에서 1예, 판엽고정에 의한 재치환이 SJM에서 1예 있었다. 결론: 최근 국내에서 흔히 사용되고 있는 5종의 기계판막을 수술 후에 초음파심음향도로 추적조사한 결과 동일한 판막크기에서 각 판막간의 기능적 차이는 없는 것으로 조사되었다.

한국형틸팅열차 틸팅기구장치 부하특성 평가 연구(II) - 대차/차체 인터페이스 조정에 의한 정적부하 영향분석 (Study for Loading Characteristic of Tilting Mechanism on Korea Tilting Train (II) - Adjustmemt for Interface of carbody and Bogie)

  • 고태환;이왕상;이범상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.951-956
    • /
    • 2011
  • As the evaluation of loading characteristic on tilting mechanism is the most important one of the function test of tilting mechanism, the changing characteristic of load must be investigated on tilting of carbody for both the static and running condition of train. In this study, we reduced the load of tilting mechanism by adjusting the interface of carbody and bogie such as the weight balance, level of underframe, height of leveling valve, height of axle box and center position of tilting actuator with the characteristic curve of load for optimal condition of the tilting mechanism obtained in the previous study. Furthermore, the factor and effect of the interfacial structures respecting the load of tilting mechanism was evaluated by analyzing the changing characteristic of load obtained in the process of adjustment of interfaces. From these data, we will propose the maintenance standards for interfacial structures and tilting mechanism in order to minimize the load of tilting mechanism by analyzing in detail the characteristic of load for the main factors of the interfacial structure effecting on the load of tilting mechanism.

  • PDF

A study on the fine structure of marine diatoms in Korean coastal waters: Genus Thalassiosira 5

  • Park, Joon-Sang;Lee, Jin-Hwan
    • ALGAE
    • /
    • 제25권3호
    • /
    • pp.121-131
    • /
    • 2010
  • Thalassiosira species were collected from October 2007 to January 2009 in an attempt to better understand species diversity of the genus Thalassiosira in Korean coastal waters. A total of 5 Thalassiosira species (T. concaviuscula, T. oceanica, T. partheneia, T. simonsenii and T. nanolineata) were identified here. Most species in this study were of small size, and 5 species were recorded for the first time in Korean coastal waters. Using a scanning electron microscope (SEM), we described distinctive characteristics of fine structure that proved to be important diagnostic characteristics for the identification of each species. The most important diagnostic characteristics for Thalassiosira species identification were the marginal strutted processes, the position of labiate processes, and the areolation. The differential characteristics of the species studied were: T. concaviuscula has a double layered external tubes on the marginal strutted processes; T. oceanica shows marginal ridges that are interlinked between the marginal strutted processes; the valve face of T. partheneia is fairly convex and its labiate process is positioned midway between two strutted processes; T. simonsenii is characterized by two labiate processes and somewhat coarse areolae; and, T. nanolineata has several central strutted processes and linear areolation.

유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구 (A study of Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer)

  • 안경관;이민수;조용래;윤주현;조우근;윤홍수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1075-1080
    • /
    • 2007
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

  • PDF

Study on the Damping Performance Characteristics Analysis of Shock Absorber of Vehicle by Considering Fluid Force

  • Lee Choon-Tae;Moon Byung-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.520-528
    • /
    • 2005
  • In this study, a new mathematical dynamic model of displacement sensitive shock absorber (DSSA) is proposed to predict the dynamic characteristics of automotive shock absorber. The performance of shock absorber is directly related to the vehicle behaviors and performance, both for handling and ride comfort. The proposed model of the DSSA has two modes of damping force (i.e. soft and hard) according to the position of piston. In this paper, the performance of the DSSA is analyzed by considering the transient zone for more exact dynamic characteristics. For the mathematical modeling of DSSA, flow continuity equations at the compression and rebound chamber are formulated. And the flow equations at the compression and rebound stroke are formulated, respectively. Also, the flow analysis at the reservoir chamber is carried out. Accordingly, the damping force of the shock absorber is determined by the forces acting on the both side of piston. The analytic result of damping force characteristics are compared with the experimental results to prove the effectiveness. Especially, the effects of displacement sensitive orifice area and the effects of displacement sensitive orifice length on the damping force are observed, respectively. The results reported herein will provide a better understanding of the shock absorber.

고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구 (A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.