• Title/Summary/Keyword: valve detachment

Search Result 12, Processing Time 0.023 seconds

Emergency Quadrido-Bentall Procedure for Aortic Rupture in a Patient with Behcet's Disease

  • Park, Sung Jun;Lee, Jeong-woo;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.364-367
    • /
    • 2015
  • Cardiovascular involvement in cases of Behcet's disease is a rare but life-threatening condition, and prosthetic valve detachment is a frequent and serious complication attributable to Behcet's disease following the surgical repair of aortic regurgitation. We report the case of a patient with Behcet's disease presenting with contained aortic rupture around the aortic root. The patient had previously undergone aortic valve surgery three times due to recurrent prosthetic valve detachment. An emergency operation was performed, consisting of aortic root replacement (ARR) using a composite valved conduit and the replacement of the hemiarch. ARR may be an appropriate surgical option for patients with Behcet's disease in order to prevent recurrence of the disease.

A Study of Electrocardiographic Change and Tricuspid Competence after Temporary Detachment for Closure of Ventricular Septal Defect (삼첨판막절개아 심실중격결손증의 수술 이후의 삼첨판막의 기능에 대한 연구)

  • 정성운;박준호;김종원
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.633-637
    • /
    • 2003
  • Sometimes temporary tricuspid valve detachment is applied for closure of ventricular septal defect to facilitate good exposure and avoiding ventriculotomy, but most surgeons hesitate to do it in the fear of tricuspid incompetence. Moreover in recent textbooks the technique of temporary tricuspid detachment is only described for exceptional situations and is not further analysed or commented on. Material and Method: Retrospective study was carried out in all 11 patients operated between 1985 to 1994, with preoperative data and postoperative course and recent echocardiographic and electrocardiographic data. Result: On the basis of the area of the color flow jet, tricuspid valvular regurgitation was graded as none in 9 and trivial in 2, and significant electrocardiographic heart block did not developed in any patients. Conclusion: Takedown and attachment of the tricuspid valve is a safe and effective technique that improves exposure for ventricular septal defect, and does not adversely effect tricuspid valve competence and electrocardiography.

Aortic Root Replacement with Homograft in Behcet's Disease -A Case Report- (베체씨 병에서의 동종 이식편을 이용한 대동맥 근위부 치환술 - 1례 보고 -)

  • Moon, Hyeon-Jong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.92-96
    • /
    • 1997
  • The prognosis of Behfet's disease characterized by recurrent orogenltal ulcers and ocular and skin lesions depends upon the complications in the central nervous system, the gastrointestinal tract And the vascular system. Cardiac involvement, especially aortic regurgitation, is quite uncommon and hemodynamic instability is usually treated with ope heart surgery. But serious postoperative complications had been reported in many cases, which are prosthetic valve detachment, paravalvular leakage, conduction disturbance, and false aneurysm. Many efforts to prevent the complications have been made such as application of cryopreseved homograft. We have described an experience of root replacement with homograft in d 39 year-old male patient for prosthetic valve detachment because of Behfet's aorlitis with a review of the literatures regarding treatment, complication, and prognosis.

  • PDF

Redo AVR: One Case Report (대동맥판막 재이식술 -1예 보고-)

  • Seong, Sang-Hyeon;Seong, Suk-Hwan;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.254-258
    • /
    • 1982
  • We have experienced one case of Redo AVR which was performed 13 months after initial operation. The patient had received AVR [Bjork-Shiley disc valve] and MVR [Ionescu-Shiley tissue valve] because of ASI and MSI at March, 1981. During follow up through the OPD, he complained exertional dyspnea and progressive jaundice with hemolytic anemia was also noticed since 1 month prior to readmission. Cardiac catheterization and angiography revealed periaortic valvular leakage due to partial detachment of previously replaced prosthetic aortic valve. Re-replacement of prosthetic aortic valve with Ionescu-Shiley valve was performed and the patient was discharged at 17th POD without any complications.

  • PDF

Clinical Analysis of Reoperation for Prosthetic Valve Replacement Report of 12 cases (인공판막 치환수술 재수술에 대한 임상적 고찰 -12예보고-)

  • 장진우;이연재
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.390-395
    • /
    • 1997
  • Between May 1986 and May 1996, 269 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 70 cases and mechanical valve was replaced in 232. Of this 12 patients performed reoperations for replacement, and the mean interval between primary valve operation and reoperation was 87.6 months for mitral valve and )7.7 months for aortic valve. There were 10 women and 2 me , agcd from 22 to 68 years(mean 45). A bioprosthetic valve was implanted in 8 cases and a mechanical valve was implanted in 4 cases for initial operation. llidications for reoperation were structural deterioration in 5 cases(42%), valve thrombus in 5 cases(42%) and endocarditis in 2 cases(17%). Operations performed included 3 aortic valve replacements(25%), 9 mitral valve replacements(75%). Wc used mechanical valve in llcases(92%) and tissue valve in 1 case(8%) for reoperation. There were 2 early operative deaths because of valve detachment and of acute respiratory failure. Among ten survivor's, there were no late deaths with follow up of 35.8 months.

  • PDF

A Study on the Discharge Pressure Ripple Characteristics of the Pressure Unbalanced Vane Pump (압력 비평형형 유압 베인 펌프의 토출 압력 맥동 특성 연구)

  • Jang, Joo-Sup
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.55-63
    • /
    • 2009
  • This paper reports on the theoretical and experimental study of the pressure ripples in a pressure unbalanced type vane pump which have widespread use in industry. Because they can infinitely vary the volume of the fluid pumped in the system by a control. Pressure ripples occur due to the flow ripples induced by geometry of side plate, leakage flow, reverse flow from the outlet volume produced by pressure difference between pumping chamber and outlet volume when the pumping chamber connected with the outlet volume. In this paper, we measured the pressure variation of a pumping chamber, reaction force on a cam ring, the mathematical model for analyzing the pressure ripples which included vane detachment and fluid inertia effects in notch area has been presented, and was applied to predict the level and the wave form of the pressure ripples according to operating conditions.

Corrective surgery of truncus arteriosus (총동맥간증의 교정수술)

  • 조형곤
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.457-463
    • /
    • 1986
  • Truncus Arteriosus is uncommon, accounting for 0.4%-2.8% of all congenital cardiac malformations. Truncus arteriosus has a poor prognosis in early infancy and defined as "a single arterial trunk that leaves the heart by way of a single arterial valve and that gives rise to the coronary, systemic and one or both pulmonary arteries directly." Through antemortem study of patients with truncus arteriosus the development of surgical techniques for palliation and correction was established. Recently we had surgical experience of truncus arteriosus - Collett '||'&'||' Edwards type 2. The main pulmonary artery was originated from truncus at right posterolateral aspect. Truncal valve was tricuspid with good coaptation. Ventricular septal defect was subarterial type of 2.0 cm in diameter. After detachment of the main pulmonary artery from truncus, truncus was repaired directly. Ventricular septal defect was closed with Dacron patch. Extracardiac valved conduit [Carpentier-Edwards: 16mm] was employed for making continuity between right ventricular outflow tract and pulmonary artery. Postoperatively, incomplete right bundle branch block on electrocardiogram was continued. Patient was died due to respiratory failure in postoperative 40 days.s.

  • PDF

A Study on the High Temperature Filtration Performance Test of Low Density Ceramic Filters (저밀도 세라믹 필터의 고온 여과 성능시험에 관한 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.75-84
    • /
    • 2001
  • Hot gas filtration method via using ceramic filters is an evolving technology applicable to numerous industrial and air pollution control processes. Alumino silicate, organic and inorganic binders were the major raw materials in manufacturing ceramic filters. In this work, disc type ceramic filters(50$\phi$$\times$10t) were manufactured by vacuum forming processes using ceramic raw materials. The porosity and bulk density of disc type ceramic filers ranged from 86 to 89% and from 0.27 to 0.36 g/㎤, respectively. In this work disc type ceramic medium were tested utilizing coupon experimental apparatus. Disc type filters showed high collection efficiencies over 99.96% with Darchs law coefficients of 4.1$\times$10(sup)10~9.63$\times$10(sup)10/$m^2$ depending on mean pore sizes. In addition, filtration and detachment of ceramic filters turned out to be performed effectively using 10 cm/sec face velocity, 5 minutes filtration cycle, 100msec pulse jet valve opening time and 3 bar pulsing pressure.

  • PDF

Surgical Correction of Tetralogy of Fallot in Adults - 101 Cases Report - (성인 활로씨 4징증 수술치험 101예 보고)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.649-655
    • /
    • 1988
  • One hundred and one patients with tetralogy of Fallot who were older than 16 years of age underwent a total correction of the anomaly between May, 1964 and July, 1987. This group comprised 14.9% of the 679 consecutive patients who had repair of the tetralogy at our institution during the same period. Of the 101 patients, 8 had a previous shunt procedure for palliation. The preoperative mean hemoglobin value was 16.9*1.0% and the mean systemic oxygen saturation, 84.4*0.9%. In 76 patients[75.2%], a type II ventricular septal defect was seen whereas in 14 patients[13.9%], the defect was type I. In 72 patients[71.3%], other cardiac anomalies were present which included patent foramen ovale in 37.6%, atrial septal defect in 8.99b, vegetations in 6.9%, right sided aortic arch in 5.9% and coronary artery anomaly in 5.0%. The right ventricular outflow obstruction was caused most commonly by combination of infundibular and valvular stenosis[74.3%], followed by isolated infundibular stenosis[19.8%] and valvular stenosis [5.9%] alone in order. The preoperative mean diameter of the pulmonary valve ring size was 10.2*0.5 mm in diameter. A transannular patch enlargement of the right ventricular outflow tract was performed in 28 patients and, in 12 a pericardial monocusp was utilized. Major anomalous aorto-pulmonary vessels were encountered in 5 patients which were detected before or during the operation. In 3 patients, they were ligated beforehand to control the flooding of the operative field. Postoperatively, the mean systolic pressure gradient between the right ventricle and the main pulmonary artery was 16.2*2.3 mmHg and the mean systolic pressure- ratio between the right and the left ventricle was 45.3*2.0%. Perioperative complications including bleeding in 8.9%, pleural effusion in 7.9%, dysrrhythmia in 4.9%, and residual VSD in 4.0%. Operative mortality was 8.9%. There has been no operative death in the recent 65 cases since 1981. There were 2 late deaths, 68 and 113 months after surgery. There were 2 late detachment of the VSD patch during the follow-up period. Of the 6 patients with patch detachment found during the postoperative period, 3 had subacute bacterial endocarditis before or after the operation indicating The serious nature of this complication. Two of these patients subsequently underwent a successful reoperation.

  • PDF

Reoperation for congenital heart disease (선천성 심장기형에 대한 2차수술로서의 개심술)

  • Ahn, H.;Sung, S.W.;Kim, Y.J.;Roh, J.R.;Suh, K.P.
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.280-287
    • /
    • 1986
  • Between March 1978 and August 1985, 29 cases at various congenital heart diseases were reoperated because of remnant shunt of residual anomalies at Seoul National University Hospital. They were consisted of 10 cases of Tetralogy, 4 simple VSD, 6 complicated VSD. 3 partial ECD, and 5 other rare congenital anomalies. The interval between the initial and the second procedure ranged from 1 day to 122 months [mean; 26.9 months]. In 4 cases of them, the second procedure was done during initial hospitalization within 3 weeks post-operatively. The primary operation intended to be corrective surgery except four whose primary operation was palliative or exploratory one even though it was done with extracorporeal circulation. The indication for second operation was mainly residual shunt or valvular obstruction due to patch detachment or inadequate relief of stenotic lesion. Others were paravalvular leak, valvuloplasty failure, prosthetic valve failure, and inadequate primary diagnosis. Four patients were dead [14.3%]; three complicated VSD`s and one Tetralogy. There were 7 cases of nonfatal complication with subsequent improvement except one [diffuse cerebral dysfunction].

  • PDF