• Title/Summary/Keyword: value contrast

Search Result 1,403, Processing Time 0.026 seconds

The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography (고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Ho-Beom;Na, Sa-Ra;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5682-5688
    • /
    • 2013
  • The purpose of this study is to maximize diagnositc usefulness with increasing signal to noise ratio(SNR) and contrast to noise ratio(CNR) by using a 1mmol/mL gadolinium contrast agent. From January 2012 to June 2013 fourty-seven patients were underwent the MRI scanning to investigate the contrast difference in gadolinium content. Twenty of the patients were injencted the commercial contrast agent containing 0.5mmol/mL gadolinium and the rest of them were injected the new contrast agent containing 1mmol/mL gadolinium called gadobutrol. We measured and evaluated each SNR and CNR of the hip joint space, iliopsoas muscle and femoral head. As a result, using the 1mmol/mL gadolinium contrast agent had the higher SNR results than using the 0.5mmol/mL agent(27% in the hip joint, 30.01% in the femoral head). Also CNR using the 1mmol/mL gadolinium agent was proved to be higher than that of using 0.5mmol/mL agent(28.31% in the ilopsoas muscle and 26.74% in the femoral head). Therefore, the contrast agent containing more gadolinium like 1mmol/mL used in this study is more effective to shorten T1 relaxation time, so it increases the signal intensity and CNR and furthermore maximizes diagnostic value. This study reports the usefulness of the 1mmol/mL contrast agent in the contrast-enhanced magnetic resonance hip arthrography for the first. Therefore, it can be considered to have an meaningful academic value as showing the method for increasing the diagnostic usefulness by using the 1mmol/mL contrast agent.

A Study on the Value of Environmental-friendly's Certification for the Rice (쌀의 친환경인증 가치에 대한 연구)

  • Kim, Ji-Hoon;Yang, Sung-Bum
    • Korean Journal of Organic Agriculture
    • /
    • v.25 no.1
    • /
    • pp.23-35
    • /
    • 2017
  • The objective of this study is to analyze a price of environment-friendly and conventional rice with POS data. And we estimate the value of environment-friendly's certification with hedonic price model. In case of price level, organic and pesticide-free rice is higher than conventional rice, 22.5% and 10.6%, respectively. In contrast, price variation of conventional rice is higher environment-friendly rice. The value of organic and pesticide are 839.5 Won and 313.7 Won, respectively. As time goes by, the certification's value goes down in environment-friendly rice. In particular, price level and certification's value of pesticide-free rice is similar with conventional rice. The results of this study show that price of the environment-friendly rice is not higher than expected. Therefore it is necessary to establish a new marketing and promotion strategies for environment-friendly rice.

Studies on Functional Properties of Mulberry Leaf Extracts and Quality Characteristics of Mulberry Leaf Muffins (뽕잎 항산화능 및 뽕잎가루 머핀의 품질특성)

  • Lee, Hye-Yeon;Jung, Hyeon-A;Kim, Dong-Han;Kwon, Hoo-Ja;Lee, Myung-Hee;Kim, An-Na;Park, Chan-Sung;Yang, Kyung-Mi;Bae, Hyun-Joo
    • Korean journal of food and cookery science
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2011
  • The function of mulberry leaves and the quality of muffins including mulberry leaves were examined. The electron donating ability of both a water and ethanol extract was 40% for both at 100 ppm, 62 and 72% at 500 ppm, and 77 and 83% at 1,000 ppm respectively. These experiments showed good oxidized substance activity. The SOD-like ability of the water and ethanol extracts at 1,000, 500, and 300 ppm was 49% and 55%, 33% and 39%, and 28% and 33% respectively. These results show that the ethanol extract had higher SOD-like ability than that of the water extract. The nitrite scavenging abilities of 1,000 ppm of the mulberry leaf water extract and ethanol extract at pHs of 1.2 and 3.0 were 40.5 and 47%, and 20 and 22% respectively. The Hunter lightness value tended to be lower as the amount of added mulberry leaves increased compared to the contrast set, so the lightness level with a 7% addition was the lowest. The contrast set was the highest for redness and added mulberry leaves tended to decrease redness at 3% but tended to increase it again with additions >3%. The b-value (yellowness) showed a similar tendency as redness. Adding Mulberry leaves tended to decrease the contrast set to the lowest level, then values increased slowly to a peak at 5% added mulberry leaf and then decreased thereafter. Strength and hardness were less after increasing added mulberry leaf. Cohesiveness, springiness, gumminess and brittleness, decreased at up to 5% added mulberry leaves but the 7% addition showed the same level as the contrast set. The mulberry leaves muffins were less preferred to the contrast set in appearance and color. However, the mulberry leaf muffins were preferred to the contrast set in taste and flavor but the result was not significant. Overall the quality of the muffins with 3% added mulberry leaves was preferred over the 1% added mulberry leaf muffins.

Prognostic Prediction Based on Dynamic Contrast-Enhanced MRI and Dynamic Susceptibility Contrast-Enhanced MRI Parameters from Non-Enhancing, T2-High-Signal-Intensity Lesions in Patients with Glioblastoma

  • Sang Won Jo;Seung Hong Choi;Eun Jung Lee;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1369-1378
    • /
    • 2021
  • Objective: Few attempts have been made to investigate the prognostic value of dynamic contrast-enhanced (DCE) MRI or dynamic susceptibility contrast (DSC) MRI of non-enhancing, T2-high-signal-intensity (T2-HSI) lesions of glioblastoma multiforme (GBM) in newly diagnosed patients. This study aimed to investigate the prognostic values of DCE MRI and DSC MRI parameters from non-enhancing, T2-HSI lesions of GBM. Materials and Methods: A total of 76 patients with GBM who underwent preoperative DCE MRI and DSC MRI and standard treatment were retrospectively included. Six months after surgery, the patients were categorized into early progression (n = 15) and non-early progression (n = 61) groups. We extracted and analyzed the permeability and perfusion parameters of both modalities for the non-enhancing, T2-HSI lesions of the tumors. The optimal percentiles of the respective parameters obtained from cumulative histograms were determined using receiver operating characteristic (ROC) curve and univariable Cox regression analyses. The results were compared using multivariable Cox proportional hazards regression analysis of progression-free survival. Results: The 95th percentile value (PV) of Ktrans, mean Ktrans, and median Ve were significant predictors of early progression as identified by the ROC curve analysis (area under the ROC curve [AUC] = 0.704, p = 0.005; AUC = 0.684, p = 0.021; and AUC = 0.670, p = 0.0325, respectively). Univariable Cox regression analysis of the above three parametric values showed that the 95th PV of Ktrans and the mean Ktrans were significant predictors of early progression (hazard ratio [HR] = 1.06, p = 0.009; HR = 1.25, p = 0.017, respectively). Multivariable Cox regression analysis, which also incorporated clinical parameters, revealed that the 95th PV of Ktrans was the sole significant independent predictor of early progression (HR = 1.062, p < 0.009). Conclusion: The 95th PV of Ktrans from the non-enhancing, T2-HSI lesions of GBM is a potential prognostic marker for disease progression.

Image Enhancement Using The Contrast Sensitivity Function (Contrast Sensitivity 함수를 이용한 영상화질 개선 방법)

  • Bang, Seangbae;Kim, Wonha
    • Journal of Broadcast Engineering
    • /
    • v.20 no.2
    • /
    • pp.238-247
    • /
    • 2015
  • We develop the signal processing method for adaptive implementing direction of signal and the frequency sensitivity of human visual system(HVS). Existing multibnad energy scaling method makes ringing artifact because it does not consider signal direction. To solve this problem, we use block gradient for signal direction in addition to existing method. And we use the fact that frequency component of signal is more sensitive than value of signal over human eyes. we enhance the signal according to contrast sensitivity function(CSF) which is the model of frequency sensitivity of human eye. Compared that the existing analysis models only improve the efficiencies in the existing systems, the developed method can process the image signals to be more desirable and suitable to HVS.

Extent of Contrast Enhancement on Non-Enhanced Computed Tomography after Intra-Arterial Thrombectomy for Acute Infarction on Anterior Circulation : As a Predictive Value for Malignant Brain Edema

  • Song, Seung Yoon;Ahn, Seong Yeol;Rhee, Jong Ju;Lee, Jong Won;Hur, Jin Woo;Lee, Hyun Koo
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2015
  • Objective : To determine whether the use of contrast enhancement (especially its extent) predicts malignant brain edema after intra-arterial thrombectomy (IAT) in patients with acute ischemic stroke. Methods : We reviewed the records of patients with acute ischemic stroke who underwent IAT for occlusion of the internal carotid artery or the middle cerebral artery between January 2012 and March 2015. To estimate the extent of contrast enhancement (CE), we used the contrast enhancement area ratio (CEAR)-i.e., the ratio of the CE to the area of the hemisphere, as noted on immediate non-enhanced brain computed tomography (NECT) post-IAT. Patients were categorized into two groups based on the CEAR values being either greater than or less than 0.2. Results : A total of 39 patients were included. Contrast enhancement was found in 26 patients (66.7%). In this subgroup, the CEAR was greater than 0.2 in 7 patients (18%) and less than 0.2 in the other 19 patients (48.7%). On univariate analysis, both CEAR ${\geq}0.2$ and the presence of subarachnoid hemorrhage were significantly associated with progression to malignant brain edema (p<0.001 and p=0.004), but on multivariate analysis, only CEAR ${\geq}0.2$ showed a statistically significant association (p=0.019). In the group with CEAR ${\geq}0.2$, the time to malignant brain edema was shorter (p=0.039) than in the group with CEAR <0.2. Clinical functional outcomes, based on the modified Rankin scale, were also significantly worse in patients with CEAR ${\geq}0.2$ (p=0.003) Conclusion : The extent of contrast enhancement as noted on NECT scans obtained immediately after IAT could be predictive of malignant brain edema and a poor clinical outcome.

Image characteristics of cone beam computed tomography using a CT performance phantom (CT performance phantom을 이용한 cone beam형 전산화단층영상의 특성)

  • Han, Choong-Wan;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.157-163
    • /
    • 2007
  • Purpose: To evaluate the characteristics of (widely used) cone beam computed tomography (CBCT) images. Materials and Methods: Images were obtained with CT performance phantoms (The American Association of Physicists in Medicine; AAPM). CT phantom as the destination by using PSR $9000N^{TM}$ dental CT system (Asahi Roentgen Ind. Co., Ltd., Japan) and i-CAT CBCT (Imaging Science International Inc., USA) that have different kinds of detectors and field of view, and compared these images with the CT number for linear attenuation, contrast resolution, and spatial resolution. Results: CT number of both PSR $9000N^{TM}$ dental CT system and i-CAT CBCT did not conform to the base value of CT performance phantom. The contrast of i-CAT CBCT is higher than that of PSR $9000N^{TM}$ dental CT system. Both contrasts were increased according to thickness of cross section. Spatial resolution and shapes of reappearance was possible up to 0.6 mm in PSR $9000N^{TM}$ dental CT system and up to 1.0 mm in i-CAT CBCT. Low contrast resolution in region of low contrast sensitivity revealed low level at PSR $9000N^{TM}$ dental CT system and i-CAT CBCT. Conclusion: CBCT images revealed higher spatial resolution, however, contrast resolution in region of low contrast sensitivity was the inferiority of image characteristics.

  • PDF

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Study on the Artifact pattern representation of a method using digital technology (디지털 기술을 이용한 유물의 문양표현 방법에 대한 연구)

  • Koo, Ja-Bong
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.113-121
    • /
    • 2015
  • Artifact pattern representation of a method using the digital technology is largely are two digital rubbing technique and digital contrast technique. Digital rubbing technique is clearly with the naked eye to see the original prestigious and difficult to build a digital rubbing data patterns by scanning a prestigious and patterns carved into the artifacts in three dimensions without compromising the circle to represent the three-dimensional effect by contrast it to the objective value refers to a technique that can be represented in digital. Digital contrast technique can not be calculated if the depth information of the object due to the glassy film of artefacts in a three-dimensional surface scanning and the application of this technique refers to a realistic image mapped digital technique for generating digital image contrast. Digital rubbing technique is mainly useful to express the most prestigious and patterns expressed in pottery or tile and stone monument, etc. engraved or embossed, digital contrast techniques can be used effectively to artifacts such as magnetic or glass can not be applied to the digital rubbing technique.

Molding and Optical Evaluation of Aspheric Glass Lenses for Camera Phone Module (카메라폰 모듈용 비구면 Glass렌즈의 성형 및 광학특성 평가)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Kim, Jeong-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.124-131
    • /
    • 2007
  • Aspheric glass lenses was fabricated by glass molding press(GMP), which is a plano-aspheric convox shape and intended for use as an optical design of 3 megapixel and 2.5 magnifications zoom in a camera phone module. Transcription ratio of form accuracy (PV) as well as resolution properties was measured for evaluation the molded lens. Form accuracy (PV) of the mold surface was $0.127\;{\mu}m$ in an aspheric and $0.168\;{\mu}m$ in a plano, in case of the molded lens it shows $0.205\;{\mu}m$ and $0.223\;{\mu}m$, respectively. Resolution of the molded lens was measured as a MTF[Contrast]. The molded lens shows contrast of 32.9% at 80 1p/mm and the value is similar with contrast of 33% obtained simulation.

  • PDF