• Title/Summary/Keyword: value contrast

Search Result 1,405, Processing Time 0.036 seconds

Current Saturation in the Electrical Resistivity Method (전기비저항탐사에서 전류포화현상)

  • Kang, Hye-Jin;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.370-377
    • /
    • 2010
  • In this study, we investigated the current saturation which forces the apparent resistivity to converge when the conductivity contrast between the anomalous body and background medium is greater than a specific value. Analizing theoretical and numerical solutions for some simple models, we studied the behavior of the surface charge, and how the surface charge cause the current saturation and finally lead to the convergence of the apparent resistivity in the resistivity method. As a consequence of above analysis, we verified that the current saturation makes the apparent resistivity converge to a specific value and the magnitude of the apparent resistivity anomaly be less than that of the ideal conductor or insulator in the resistivity method. In general, current saturation is considered to occur when the conductivity contrast becomes larger than 100.

Analysis of Medical Image with CD-RAD Phantom (CD-RAD Phantom을 이용한 의료영상의 분석)

  • Kim, Chang-Bok;Kim, Young-Keun;Cho, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.369-369
    • /
    • 2007
  • The physical and visual evaluation of the identical X-rays are analyzed for medical image clarity with CD-RAD Phantom on this study. The method of measurement is to research CD-RAD by X-rays and to acquire images through image processing equipment, the image analyses are carried out by physical evaluation with statistical method through CD-RAD analyser program, and the visual evaluation of the identical X-rays is carried out by blind test for 20 observers. The result of it is that IQF value of the physical evaluation of Contrast-detail curve is 25 and IQF value of the visual evaluation is 30, so it is revealed that the physical evaluation is superior to the visual one. The special qualities of medical images have much importance of the transmission capacity of information to the image analyser, so it is concluded that 0비ective methods of the physical and visual analyses should be carried out side by side.

  • PDF

A Study on the Mechanical Properties of Duplex Stainless Steel Weldment According to Mo Contents

  • Bae, Seong Han;Lim, Hee Dae;Jung, Won Jung;Gil, Woong;Jeon, Eon Chan;Lee, Sung Geun;Lee, Hyo Jong;Kim, In Soo;Lee, Hae Woo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.9
    • /
    • pp.645-651
    • /
    • 2012
  • This study investigated changes in phase fraction caused by the addition of Mo, as well as the subsequent behaviour of N and its effect on the mechanical properties of welded 24Cr-N duplex stainless steel weld metals. Filler metal was produced by fixing the contents of Cr, Ni, N, and Mn while adjusting the Mo content to 1.4, 2.5, 3.5 wt%. The delta ferrite fraction increased as the Mo content increased. In contrast, the ${\gamma}$ fraction decreased and changed from a round to an acicular shape. Secondary austenite (${\gamma}^{\prime}$) was observed in all specimens in a refined form, but it decreased as the Mo content increased to the extent that it was nearly impossible to find any secondary austenite at 3.5 wt% Mo. Both tensile and yield strengths increased with the addition of Mo. In contrast, the highest value of ductility was observed at 1.41 wt% Mo. At all temperatures, impact energy absorption showed the lowest value at 3.5 wt% Mo, at which the amount of ${\delta}$-ferrite was greatest. There was no significant temperature dependence of the impact energy absorption values for any of the specimens. As the fraction of ${\gamma}$ phase decreased, the amount of N stacked in the ${\gamma}$ phase increased. Consequently, the stacking fault energy decreased, while the hardness of ${\gamma}$ increased.

Prognostic Value of Artificial Intelligence-Driven, Computed Tomography-Based, Volumetric Assessment of the Volume and Density of Muscle in Patients With Colon Cancer

  • Minsung Kim;Sang Min Lee;Il Tae Son;Taeyong Park;Bo Young Oh
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.849-859
    • /
    • 2023
  • Objective: The prognostic value of the volume and density of skeletal muscles in the abdominal waist of patients with colon cancer remains unclear. This study aimed to investigate the association between the automated computed tomography (CT)-based volume and density of the muscle in the abdominal waist and survival outcomes in patients with colon cancer. Materials and Methods: We retrospectively evaluated 474 patients with colon cancer who underwent surgery with curative intent between January 2010 and October 2017. Volumetric skeletal muscle index and muscular density were measured at the abdominal waist using artificial intelligence (AI)-based volumetric segmentation of body composition on preoperative pre-contrast CT images. Patients were grouped based on their skeletal muscle index (sarcopenia vs. not) and muscular density (myosteatosis vs. not) values and combinations (normal, sarcopenia alone, myosteatosis alone, and combined sarcopenia and myosteatosis). Postsurgical disease-free survival (DFS) and overall survival (OS) were analyzed using univariable and multivariable analyses, including multivariable Cox proportional hazard regression. Results: Univariable analysis showed that DFS and OS were significantly worse for the sarcopenia group than for the non-sarcopenia group (P = 0.044 and P = 0.003, respectively, by log-rank test) and for the myosteatosis group than for the non-myosteatosis group (P < 0.001 by log-rank test for all). In the multivariable analysis, the myosteatotic muscle type was associated with worse DFS (adjusted hazard ratio [aHR], 1.89 [95% confidence interval, 1.25-2.86]; P = 0.003) and OS (aHR, 1.90 [95% confidence interval, 1.84-3.04]; P = 0.008) than the normal muscle type. The combined muscle type showed worse OS than the normal muscle type (aHR, 1.95 [95% confidence interval, 1.08-3.54]; P = 0.027). Conclusion: Preoperative volumetric sarcopenia and myosteatosis, automatically assessed from pre-contrast CT scans using AI-based software, adversely affect survival outcomes in patients with colon cancer.

Measurement of Pancreatic Fat Fraction by CT Histogram Analysis to Predict Pancreatic Fistula after Pancreaticoduodenectomy

  • Wonju Hong;Hong Il Ha;Jung Woo Lee;Sang Min Lee;Min-Jeong Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.599-608
    • /
    • 2019
  • Objective: To evaluate the effectiveness of computed tomography (CT) Hounsfield unit histogram analysis (HUHA) in postoperative pancreatic fistula (PF) prediction. Materials and Methods: Fifty-four patients (33 males and 21 females; mean age, 65.6 years; age range, 37-89 years) who had undergone preoperative CT and pancreaticoduodenectomy were included in this retrospective study. Two radiologists measured mean CT Hounsfield unit (CTHU) values by drawing regions of interest (ROIs) at the level of the pancreaticojejunostomy site on preoperative pre-contrast images. The HUHA values were arbitrarily divided into three categories, comprising HUHA-A ≤ 0 HU, 0 HU < HUHA-B < 30 HU, and HUHA-C ≥ 30 HU. Each HUHA value within the ROI was calculated as a percentage of the entire area using commercial 3-dimensional analysis software. Pancreas texture was evaluated as soft or hard by manual palpation. Results: Fifteen patients (27.8%) had clinically relevant PFs. The PF group had significantly higher HUHA-A (p < 0.01) and significantly lower mean CTHU (p < 0.01) values than those of the non-PF group. The HUHA-A value had a moderately strong correlation with PF occurrence (r = 0.60, p < 0.01), whereas the mean CTHU had a weak negative correlation with PF occurrence (r = -0.27, p < 0.01). The HUHA-A and mean CTHU areas under the curve (AUCs) for predicting PF occurrence were 0.86 and 0.65, respectively, with significant difference (p < 0.01). The HUHA-A and mean CTHU AUCs for predicting pancreatic softness were 0.86 and 0.64, respectively, with significant difference (p < 0.01). Conclusion: The HUHA-A values on preoperative pre-contrast CT images demonstrate a strong correlation with PF occurrence.

Effect of the Pan Oil Type on the Releasing Power, Changes of Peroxide and Acid alue of the Oil (이형유 종류에 따른 Cake 제품의 이탈성, 이형유의 과산화물가 및 산가의 변화)

  • 이정훈;조남지
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 1998
  • This study aims to examine appropriate kinds of pan oil to release a cake from the pan coated with polyether sulphone and to prove the change of acid value and peroxide value during the process of baking. The major factor effecting the rate of release of the cakes from the pan was properties of the oils rather than the additives. The releasing rate appeared higher as the iodine value was lower. The highest releasing rate was found in the sample, which was made of coconut oil plus 2% of wax, 2% of lecithin. The changes of acid value of the pan oil between the beginning and after baking was little different. In contrast, Peroxide value showed a great change after baking.

  • PDF

Effects of vacuum and high-oxygen modified atmosphere packaging on physico-chemical and microbiological properties of minced water buffalo meat

  • Jaberi, Rahimeh;Kaban, Guzin;Kaya, Mukerrem
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.3
    • /
    • pp.421-429
    • /
    • 2019
  • Objective: In this study, the effects of vacuum (VP) and high-oxygen modified atmosphere ($80%\;O_2+20%\;CO_2$) packaging (HiOx-MAP) on physico-chemical and microbiological properties of minced water buffalo meat were investigated. Methods: After minced meat preparation, samples were packaged under VP and HiOx-MAP and stored at $2^{\circ}C{\pm}0.5^{\circ}C$ for 14 days. Samples taken on certain days were subjected to total aerobic mesophilic bacteria, total aerobic psychrotrophic bacteria, lactic acid bacteria, Pseudomonas, Enterobacteriaceae and yeast-mold counts as well as pH, color ($L^*$, $a^*$, and $b^*$) and thiobarbituric acid reactive substances (TBARS) analyses. Results: In minced water buffalo meat packaged under HiOx-MAP, TBARS value exceeded 1 mg malondialdehyde/kg on the 4th day of the storage. In VP samples, TBARS value remained close to initial TBARS value during storage. According to the findings, $a^*$ value was determined to be high in the HiOx-MAP samples within initial days of the storage. However, no significant changes in $a^*$ value were observed in VP samples during storage. In contrast, the mean value of $L^*$ was detected as higher in HiOx-MAP sample than VP samples. The count of psychrotrophic bacteria increased more than that of mesophilic bacteria during storage. The growth of Enterobacteriaceae and Pseudomonas was delayed in both the packaging methods. However, lactic acid bacteria exhibited more growth in VP samples compared to MAP samples. Conclusion: The lipid oxidation proceeded faster than expected in minced water buffalo meat packed with HiOx-MAP method. This situation adversely affected the $a^*$ value. On the other hand, similar microbiological results were obtained in both packing methods.

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF

Bi-Histogram Equalization based on Differential Compression Method for Preserving the Trend of Natural Mean Brightness (자연스러운 영상의 평균 밝기 유지를 위한 차별적 압축 방법 기반의 분할 히스토그램 평활화)

  • Lee, Jae-Won;Hong, Sung-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.453-467
    • /
    • 2014
  • A typical histogram equalization contrast enhancement effect for improving the image quality is excellent. However, because it appears that excessive changes of the brightness values, The average brightness of the image is changing in units of frames of applications such as a TV video is unsuitable. In order to solve these drawbacks, a modified method of histogram equalization on various studies have been made. But the result images of existing methods sometimes shown visual degradations such as over-enhancement and false contouring. In this paper, we propose improved contrast enhancement method through bi-histogram equalization using target mean brightness based on differential compression method. The proposed method is based on the average brightness value by dividing the histogram, the histogram for each zone, according to the frequency differential of compression. And equalize the modified histogram based on target mean brightness. This allows to suppress deterioration of picture quality, and changes in the average brightness of each frame of video, while maintaining and improving the contrast. Experimental results show that the proposed method compared to the conventional method, the average brightness of each frame from a movie well maintained, and no degradation of the image quality showed a good effect to improve the contrast.

Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer

  • Kim, Eun Young;Youn, Inyoung;Lee, Kwan Ho;Yun, Ji-Sup;Park, Yong Lai;Park, Chan Heun;Moon, Juhee;Choi, Seon Hyeong;Choi, Yoon Jung;Ham, Soo-Youn;Kook, Shin Ho
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.453-462
    • /
    • 2018
  • Purpose: This study aimed to compare the diagnostic performance of contrast-enhanced digital mammography (CEDM) and contrast-enhanced magnetic resonance imaging (CEMRI) in preoperative evaluations, and to evaluate the effect of each modality on the surgical management of women with breast cancer. Methods: This single-center, prospective study was approved by the Institutional Review Board, and informed consent was obtained from all patients. From November 2016 to October 2017, 84 patients who were diagnosed with invasive carcinoma (69/84) and ductal carcinoma in situ (15/84), and underwent both CEDM and CEMRI, were enrolled. Imaging findings and surgical management were correlated with pathological results and compared. The diagnostic performance of both modalities in the detection of index and secondary cancers (multifocality and multicentricity), and occult cancer in the contralateral breast, was compared. The authors also evaluated whether CEDM or CEMRI resulted in changes in the surgical management of the affected breast due to imaging-detected findings. Results: Eighty-four women were included in the analysis. Compared with CEMRI, CEDM demonstrated a similar sensitivity (92.9% [78/84] vs. 95.2% [80/84]) in detecting index cancer (p=0.563). For the detection of secondary cancers in the ipsilateral breast and occult cancer in the contralateral breast, no significant differences were found between CEDM and CEMRI (p=0.999 and p=0.999, respectively). Regarding changes in surgical management, CEDM resulted in similar changes compared with CEMRI (30.9% [26/84] vs. 29.7% [25/84], p=0.610). Regarding changes in surgical management due to false-positive findings, no significant differences were found between CEDM and CEMRI (34.6% [9/26] vs. 44.0% [11/25], p=0.782). Conclusion: CEDM demonstrated a diagnostic performance comparable with CEMRI in depicting index cancers, secondary cancers, and occult cancer in the contralateral breast. CEDM demonstrated similar changes in surgical management compared with CEMRI.