• Title/Summary/Keyword: value contrast

Search Result 1,403, Processing Time 0.028 seconds

The Electrical Properties of Gate Oxide due to the Variation of Thickness (두께 변화에 따른 Gate Oxide의 전기적 특성)

  • Park, Jung-Goo;Hong, Nung-Pyo;Lee, Yong-Woo;Kim, Wang-Gon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1931-1933
    • /
    • 1999
  • In this paper, the current and voltage properties on the gate oxide film due to the variation of thickness are studied. The specimen is used for n-ch power MOSFET. It is shows the leakage current and current density characteristics due to the applied electric field when the oxide thickness is each $600[\AA],\;800[\AA]$ and $1000[\AA]$, respectively. We known that the leakage current is a little higher when the voltage as reverse bias contrast with forward bias in poly gate is applied. In order to experiment for AC properties is measured for capacitance characteristics. It is confirmed that the value of input capacitance have been a lot of influenced on $SiO_2$ thickness contrast with the value of output capacitance.

  • PDF

Automated radiation field edge detection in portal image using optimal threshold value (최적 문턱치 설정을 이용한 포탈영상에서의 자동 에지탐지 기법에 관한 연구)

  • 허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.337-344
    • /
    • 1995
  • Because of the high energy of the treatment beam, contrast of portal films is very poor. Many image processing techniques have been applied to the portal images but a significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it may be remedied by separating the treatment field from the background prior to enhancement and uslng only the pixels within the field boundary in the enhancement procedure. A new edge extraction algorithm for accurate extraction of the radiation field boundary from portal Images has been developed for contrast enhancement of portal images. In this paper, portal image segmentation algorithm based on Sobel filtration, labelling processes and morphological thinning has been presented. This algorithm could automatically search the optimal threshold value which is sensitive to the variation of the type and quality of portal images.

  • PDF

Feature values of DWT using MR general imaging and molecular imaging (DWT를 이용한 MR 일반영상과 분자영상 특징추출)

  • Pack, Dae-Sung;Choi, Gui-Rack;Han, Byung-Sung;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.409-414
    • /
    • 2012
  • This study acquired molecular lmaging using nano-contrast agents, and the general condition of the same image acquisition to analyze the difference between molecular imaging and general imaging, two images are converted into DWT (Discrete Wavelet Transform). Nano-contrast agent imaging using MRI and molecular imaging using PET study of molecular imaging technology mainstream. DWT analysis of the same lesions using MRI imaging and molecular imaging block lesions are present in the lesions, illustrating the value of a high-frequency feature both highly general imaging and molecular imaging could know that. The high frequency region of the feature extraction values appear higher molecular imaging.

LANDSLIDE SUSCEPTIBILITY MAPPING AND VERIFICATION USING THE GIS AND BAYESIAN PROBABILITY MODEL IN BOEUN, KOREA

  • Choi, Jae-Won;Lee, Sa-Ro;Yu, Young-Tae
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.100-100
    • /
    • 2003
  • The purpose of this study is to reveals spatial relationships between landslides and geospatial data set, map the landslide susceptibility using the relationships and verify the landslide susceptibility using the landslide occurrence data in Bosun area in 1998. Landslide locations were detected from aerial photography and field survey and topography, soil, forest, and land use data sets were constructed as a spatial database using GIS. As the landslide occurrence factors, slope, aspect, curvature and type of topography, texture, material, drainage and effective thickness of soil, type, age, diameter and density of wood and land use were used. Is extract the relationship between landslides and geospatial database, Bayesian probability methods, likelihood ratio and weight of evidence, were applied and the ratio and contrast value that is W$\^$+/- W$\^$-/ were calculated. The landslide susceptibility index was calculated by summation of the likelihood ratio and contrast value and the landslide susceptibility maps were generated using the index. As a result, it is expected that spatial relationships between landslides and geospatial database is helpful to explain the characteristics of landslide and the landslide susceptibility map is used to reduce associated hazards, and to plan land use and construction.

  • PDF

An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station (방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석)

  • Han, Jae-Jin;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA (4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성)

  • Bae, Sung-Jin;Lim, Cheong-Hwan;Park, Byung-Rae;Shin, Woon-Jae;Kim, Jung-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

Emotional Tree Using Sensitivity Image Analysis Algorithm (감성 트리를 이용한 이미지 감성 분석 알고리즘)

  • Lee, Yean-Ran;Yoon, Eun Ju;Im, Jung-Ah;Lim, Young-Hwan;Sung, Jung-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.562-570
    • /
    • 2013
  • Image of emotional pleasure or displeasure, tension or emotional division of tranquility in the form of a tree is evaluated by weighting. Image representative evaluation of the sensitivity of the brightness contrast ratings 1 car pleasure, displeasure or stress or emotional tranquility and two cars are separated by image segmentation. Emotion Recognition of four compared to the numerical data is measured by brightness. OpenCV implementation through evaluation graph the stress intensity contrast, tranquility, pleasure, displeasure, depending on changes in the value of the computing is divided into four emotional. Contrast sensitivity of computing the brightness depending on the value entered 'nuisance' to 'excellent' or 'stress' to 'calm' the emotional changes can give. Calculate the sensitivity of the image regularity of localized computing system can control the future direction of industry on the application of emotion recognition will play a positive role.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography (위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The purpose of this study was to detect the pin hole defect of dental composite restoration using lock-in thermography method. Amplitude and phase images of the composite resin specimens were analyzed according to the lock-in frequency and the diameter of defect area. Through the amplitude image analysis, at lock-in frequency of 0.05 Hz, defect diameters 2-5 mm exhibited the highest amplitude contrast value between defective area and sound area. The lock-in frequency range of 0.3-0.5 Hz provided good phase angle contrast for the defect area. At lock-in frequency range of 0.5 Hz, defect diameter of 5 mm exhibited the highest phase contrast value. It is concluded that the infrared lock-in thermography method verified the effectiveness for detecting the pin hole defect of dental composite restoration.

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.