• 제목/요약/키워드: vacuum drainage

검색결과 38건 처리시간 0.026초

Vacuum distribution with depth in vertical drains and soil during preloading

  • Khan, Abdul Qudoos;Mesri, G.
    • Geomechanics and Engineering
    • /
    • 제6권4호
    • /
    • pp.377-389
    • /
    • 2014
  • The vacuum consolidation method which was proposed by Kjellman in 1952 has been studied extensively and used successfully since early 1980 throughout the world, especially in East and Southeast Asia. Despite the increased successful use, different opinions still exist, especially in connection to distribution of vacuum with depth and time in vertical drains and in soil during preloading of soft ground. Porewater pressure measurements from actual cases of field vacuum and vacuum-fill preloading as well as laboratory studies have been examined. It is concluded that (a) a vacuum magnitude equal to that in the drainage blanket remains constant with depth and time within the vertical drains, (b) as expected, vacuum does not develop at the same rate within the soil at different depths; however, under ideal conditions vacuum is expected to become constant with depth in soil after the end of primary consolidation, and (c) there exists a possibility of internal leakage in vacuum intensity at some sublayers of a soft clay and silt deposit. A case history of vacuum loading with sufficient subsurface information is analyzed using the ILLICON procedure.

Delayed Sternal Closure Using a Vacuum-Assisted Closure System in Adult Cardiac Surgery

  • Hyun Ah Lim;Jinwon Shin;Min Seop Jo;Yong Jin Chang;Deog Gon Cho;Hyung Tae Sim
    • Journal of Chest Surgery
    • /
    • 제56권3호
    • /
    • pp.206-212
    • /
    • 2023
  • Background: Delayed sternal closure (DSC) is a useful option for patients with intractable bleeding and hemodynamic instability due to prolonged cardiopulmonary bypass and a preoperative bleeding tendency. Vacuum-assisted closure (VAC) has been widely used for sternal wound problems, but only rarely for DSC, and its efficacy for mediastinal drainage immediately after cardiac surgery has not been well established. Therefore, we evaluated the usefulness of DSC using VAC in adult cardiac surgery. Methods: We analyzed 33 patients who underwent DSC using VAC from January 2017 to July 2022. After packing sterile gauze around the heart surface and great vessels, VAC was applied directly without sternal self-retaining retractors and mediastinal drain tubes. Results: Twenty-one patients (63.6%) underwent emergency surgery for conditions including type A acute aortic dissection (n=13), and 8 patients (24.2%) received postoperative extracorporeal membrane oxygenation support. Intractable bleeding (n=25) was the most common reason for an open sternum. The median duration of open sternum was 2 days (interquartile range [25th-75th pertentiles], 2-3.25 days) and 9 patients underwent VAC application more than once. The overall in-hospital mortality rate was 27.3%. Superficial wound problems occurred in 10 patients (30.3%), and there were no deep sternal wound infections. Conclusion: For patients with an open sternum, VAC alone, which is effective for mediastinal drainage and cardiac decompression, had an acceptable superficial wound infection rate and no deep sternal wound infections. In adult cardiac surgery, DSC using VAC may be useful in patients with intractable bleeding or unstable hemodynamics with myocardial edema.

Field instrumentation and settlement prediction of ground treated with straight-line vacuum preloading

  • Lei, Huayang;Feng, Shuangxi;Wang, Lei;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • 제19권5호
    • /
    • pp.447-462
    • /
    • 2019
  • The vacuum preloading method has been used in many countries for ground improvement and land reclamation works. A sand cushion is required as a horizontal drainage channel for conventional vacuum preloading. In terms of the dredged-fill foundation soil, the treatment effect of the conventional vacuum preloading method is poor, particularly in Tianjin, China, where a shortage of sand exists. To solve this problem, straight-line vacuum preloading without sand is widely adopted in engineering practice to improve the foundation soil. Based on the engineering properties of dredged fill in Lingang City, Tianjin, this paper presents field instrumentation in five sections and analyzes the effect of a prefabricated vertical drain (PVD) layout and a vacuum pumping method on the soft soil ground treatment. Through the arrangement of pore water pressure gauges, settlement marks and vane shear tests, the settlement, pore water pressure and subsoil bearing capacity are analyzed to evaluate the effect of the ground treatment. This study demonstrates that straight-line vacuum preloading without sand can be suitable for areas with a high water content. Furthermore, the consolidation settlement and consolidation degree system is developed based on the grey model to predict the consolidation settlement and consolidation degree under vacuum preloading; the validity of the system is also verified.

Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

  • Porcel, Jose M.
    • Tuberculosis and Respiratory Diseases
    • /
    • 제81권2호
    • /
    • pp.106-115
    • /
    • 2018
  • Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (${\leq}14F$) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established.

Experimental study on treatment of waste slurry by vacuum preloading with different conditioning agents

  • Wu, Yajun;Jiang, Haibo;Lu, Yitian;Sun, Dean
    • Geomechanics and Engineering
    • /
    • 제17권6호
    • /
    • pp.543-551
    • /
    • 2019
  • In China, serious environmental problems are induced by the extremely soft construction waste slurries in many urban areas, and there is no appropriate method to treat it presently. In this paper, four model tests were conducted to investigate the efficiency of waste slurry treatment by combining three conditioning agents which can change characteristics of the slurries with a traditional vacuum preloading method. The tests of size analysis of particle aggregate were conducted to investigate the influence of different conditioning agents on the size distributions of particle aggregate. During the model test, the discharged water volumes were monitored. The pore-size distribution and void ratio of the waste slurries after the vacuum preloading were measured by mercury intrusion porosimetry (MIP). It is found that 1) During the natural precipitation, volume of water out of the organic agent is higher than that of the mixed agent, but it is smaller than that of the mixed agent in the vacuum preloading stage; 2) the mixed agent has a higher total volume of water out than the organic agent and the inorganic agent after test, while the organic agent and the inorganic agent have little difference with respect to the drainage effect. The results demonstrate that the combination of mixed conditioning agent and vacuum preloading for the solid-liquid separation in waste slurry has a satisfactory effect and can be applied in engineering practice.

Evaluation of Dewatering of Cellulose Nanofibrils Suspension and Effect of Cationic Polyelectrolyte Addition on Dewatering (셀룰로오스 나노피브릴 현탁액의 탈수성 평가 및 양이온성 고분자전해질 투입의 영향)

  • Ryu, Jaeho Ryu;Sim, Kyujeong;Youn, Hye Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • 제46권6호
    • /
    • pp.78-86
    • /
    • 2014
  • Since cellulose nanofibrils (CNF) has large specific surface area and high water holding capacity, it is very difficult task to remove water from the CNF suspension. However, dewatering of CNF suspension is a prerequisite of following processes such as mat forming and drying for the application of CNF. In this study, we evaluated the drainage of cellulose fibers suspension under vacuum and pressure conditions depending on the number of grinding passes. Also, the effect of the addition of cationic polyelectrolyte on dewatering ability of CNF suspension was investigated. Regardless of dewatering condition, the total drained water amount as well as the drainage rate were decreased with an increase in the number of grinding passes. Pressure dewatering equipment enables us to prepare wet CNF mat with relatively higher grammage. The cationic polyelectrolytes improved the dewatering ability of CNF suspension by controlling the zeta potential of CNF. The fast drainage was obtained when CNF suspension had around neutral zeta potential.

Analysis of Consolidation Behavior for Dredged Clay with Horizontal Drains (수평배수재가 설치된 준설매립 점토의 압밀 거동 해석)

  • 김수삼;장연수;박정순;오세웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.641-648
    • /
    • 2000
  • The horizontal drain method by installing drains horizontally in the ground is often used to expedite the dispersion of pore water and to increase the strength of dredged soft clay under the action of gravity or vacuum. In this study a numerical analysis method is developed to predict the consolidation process of soft ground with horizontal drains. One-dimensional self-weight consolidation theory is extended tn three-dimensions] theory with appropriate boundary conditions of horizontal drains. In the condition of pore water drainage by gravity, the behavior of the dredged clay with horizontal drains is compared with that of the clay without drains. The influence of design factors of drains on consolidation process is also analyzed.

  • PDF

Geotechnical Evaluation on the Application of Reactive Vertical Drainage Method (반응성연직배수공법의 적용에 대한 지반공학적 평가)

  • Na, Hyoung-Yun;Chae, Deokho;Oh, Myoung-Hak;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • 제13권7호
    • /
    • pp.13-17
    • /
    • 2012
  • Recently, our ocean development paradigm is changing so that the development focus has been moved from the port facility developments to creating useful marine space. This paradigm accords well with the current green technology and helps the growth of service industries and the development from this paradigm can become a national land mark. Accordingly, the concept of creating marine waste landfill by the development of resource recycling technology has been introduced for eco-friendly space as an artificial island in future. Therefore, this study introduces the reactive vertical drainage method that is to pursue the purification of pollutants as well as stabilization of newly deposited soils in marine environments. To install the reactive vertical drainage piles for more effective feasibility and constructability, placements of drainage mid-layer are considered in the geotechnical viewpoint. Consolidation characteristics were evaluated by standard consolidation tests after several types of model test. As s result, the application of mid-layer drainage is strongly recommended in the reactive vertical drainage to quickly stabilize newly deposited soils. And vacuum consolidation method has better consolidation characteristic than vertical loading method in terms of the settlements predicted by additional stress for further use as an artificial island.

Evaluation of Remediation of Contaminated Soil Using PVDs (연직배수재를 이용한 오염도턍복원 특성 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun;Roh, Jeong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1400-1407
    • /
    • 2005
  • There are a number of approaches to in situ remediation that are used at contaminated sites for removing contaminants from the contaminated zone without excavating the soil. These include soil flushing, dual phase extraction, and soil vapor extraction. Of these techniques, soil flushing is the focus of the investigation in this paper. The concept of using prefabricated vertical drains(PVDs) for remediation of contaminated sites with fine-grained soils is examined. The PVD system is used to shorten the drainage path or the groundwater flow and promote subsurface liquid movement expediting the soil flushing process. The use of PVDs in the current state of practice has been limited to soil improvement. The use of PVDs under vacuum conditions is investigated using sample soil consisting of silty sand.

  • PDF