• Title/Summary/Keyword: vacuum Co2

Search Result 805, Processing Time 0.033 seconds

Establishment of self-specification and shelf-life by standardization of manufacturing process for lyophilized Tenebrio molitor larvae (동결건조 갈색거저리 유충의 제조공정 표준화에 따른 자가규격 및 유통기한 설정)

  • Chung, Mi Yeon;Lee, Jeong-Yong;Lee, Jin-Chae;Park, Kil-Su;Jeong, Jun-Pyo;Hwang, Jae-Sam;Goo, Tae-Won;Yun, Eun-Young
    • Journal of Sericultural and Entomological Science
    • /
    • v.52 no.1
    • /
    • pp.73-78
    • /
    • 2014
  • This study was carried out to establish the self-specification and shelf-life by standardization of manufacturing process for Tenebrio molitor larvae. First, standardization of manufacturing process for T. molitor was set up. Sterilization for larvae placed on a multistage shelf with intervals of about 10 cm was carried out at $115^{\circ}C$, $1kgf/cm^2$ for 10 min. After sterilization, T. molitor larvae were frozen at less than $-35^{\circ}C$ for more than 12 hrs. And then, they were dried under $-15^{\circ}C$, 0.5 torr vacuum for more than 30 hrs. Second, we decided self-specification for T. molitor larvae. Their moisture, acidity, peroxide, crude protein and crude fat level should be 5% or less, 3 mg/g or less, 30 meq/g or less, 45% or more, and 25% or more, respectively. Also, oleic acid, representative material, level was set up 11 ~ 16%. Third, we decided shelf-life by analysis of the physicochemical characteristic, sensory evaluation and microbial indicators. The final expiry date for lyophilized T. molitor larvae in PET bottle was calculated as 12 months from date of manufacture. We expect that optimal manufacturing process system, self-specification, and shelf-life proposed in this study can be used in industrial production of T. molitor as a novel food.

Preservation of Fried Fish Meat Paste by Irradiation (감마선 조사에 의한 튀김어묵의 품질보존)

  • Cho, Han-Ok;Kwon, Joong-Ho;Byun, Myung-Woo;Lee, Mi-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.474-481
    • /
    • 1985
  • Radurization effects on fried fish meat paste with Co-60 gamma irradiation at 0-5 kGy and physicochemical aspects of the stored samples at low ($3{\pm}1^{\circ}C$, LT) and room ($10-20^{\circ}C$, RT) temperatures were investigated. The initial microbial loads of the samples were $2.2{\times}10^3/g$ in total bacterial count, $2.8{\times}10^2/g$ in yeasts & molds, and $1.0{\times}10^2/g$ in coliform group, respectively. An irradiation dose of more than 3 kGy was shown to be effective for the radurization of stored samples and there is no apparent difference between air and vacuum packaging groups. The chemical components related to the quality underwent similar changes in the nonirradiated and irradiated groups; however, as the storage time was prolonged the quality of nonirradiated samples rapidly deteriorated. Textural parameters of the samples were little affected by the applied doses, and sensory evaluations showed that 3 kGy irradiation was the optimum dose level to extend the shelf-life of fried fish meat paste up to 2 times at RT and 3 to 4 times at LT, respectively compared with the nonirradiated control.

  • PDF

Historical Investigation on Development of Produce and Packages or Physical Analysis of Packaging's Materials of Cheese in Korea since 1967-2 (1967년 이후 한국(韓國)에서 치즈제품(製品)의 개발(開發)과 포장(包裝)의 변화(變化) 및 그 포장재(包裝材)의 생물학적(生物學的) 조사연구(調査硏究)-2)

  • Kim, Duck-Woong
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.5 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Physical analysis of some composite films of outer packaging at process cheeses in Korea is as following. In comparison with four composite films, tensile strength is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;MD9.55kg/15mm,\;TD8.95kg/15mm>79.3{\mu}PET/PVDC/L-LDPE\;film\;MD5.37kg/15mm,\;TD5.01kg/15mm>96.9{\mu}PE/PVDC/PE\;film\;MD5.42kg/15mm,\;TD4.73kg/15mm>61.6{\mu}PVDC/PE/AL-vac/CPS\;film\;MD4.65kg/15mm,\;TD4.22kg/15mm$. Water vapor transmission is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;0.41g/m^2{\cdot}24hr>79.3{\mu}PET/PVDC/L-LDPE\;film\;3.77g/m^2{\cdot}24hr>96.9{\mu}PE/PVDC/PE\;film\;3.81g/m^2{\cdot}24hr>61.6{\mu}PVDC/PE/AL-vac/4.91g/m^2{\cdot}24hr$. Gas transmission $O_2:N_2:CO_2$ is $72.2{\mu}PET/PVDC/PE/AL-vac/PE\;film\;1.81:0.74:4.2cc/m^2{\cdot}24hr{\cdot}atm>79.3{\mu}PET/PVDC/L-LDPE\;film\;13.4:6.4:34.2cc/m^2{\cdot}24hr{\cdot}atm>96.9{\mu}PE/PVDC/PE\;film\;15.3:7.1:42.0cc/m^2{\cdot}24hr{\cdot}atm>61.6{\mu}PVDC/PE/AL-vac/CPS\;film\;25.3:12.5:59.3cc/m^2{\cdot}24hr{\cdot}atm$ each other. And for preservation this were sealed to filths $N_2,\;CO_2$ gas or defilling ai (vacuum type) in the packaging and reserved less than $10^{\circ}C$ at refrigerator.

  • PDF

Production of Antithrombotic Material Extracted from Auricularia auricular-judae and the Verification of Its Antithrombotic Activity via Animal Test (목이버섯으로부터 추출한 항혈전물질의 제품화와 동물실험을 통한 항혈전활성 검증)

  • Park, Young-Seo;Choi, Hyuk-Joon
    • Food Engineering Progress
    • /
    • v.14 no.4
    • /
    • pp.359-366
    • /
    • 2010
  • Large-scale preparation steps of antithrombotic materials from wood ear mushroom (Auricularia auricular-judae) were established as follows. Grounded dry wood ear mushroom was extracted with 75% ethanol and its precipitate was extracted with $76^{\circ}C$ water for 2 hr followed by filter pressing. The filtrate was then concentrated by vacuum and extracted with 80% ethanol, and the resulting precipitate was then freeze-dried. The formula of the product was determined using consumer susceptibility tests as follows; mushroom extract 90.5%, high fructose corn syrup 2.0%, $\beta$-cyclodextrin 1.5%, fructo-oligosaccharide 2.0%, pear puree 4.0%. When the packed products were stored at 25, 37, or $45^{\circ}C$ for 8 weeks, there were no noticeable changes in water activity, moisture content, pH, and acidity. The viable cell number of total bacteria was slightly increased during the storage period at 25 and $37^{\circ}C$, The total bacteria were not detected in the product when stored at $45^{\circ}C$. When the product was injected intravenously into rat at the level of 1,000 mg/kg, antithrombotic activities such as activated partial thromboplastin time, thrombin time, prothrombin time, and FIB were increased when compared with the control group. When the product was administrated orally into rat at the level of 500 mg/kg, it showed the same antiplatelet activity to aspirin.

In-Vitro Fertilization and Culture of Pig Oocytes Matured In-Vitro by Liquid Boar Sperm Stored at 4$^{\circ}C$

  • Kim, M. Y.;Y. J. Yi;Y. J. Chang;Park, C. S.
    • Proceedings of the KSAR Conference
    • /
    • 2003.06a
    • /
    • pp.63-63
    • /
    • 2003
  • This study was carried out to investigate the effects of liquid boar sperm stored at 4$^{\circ}C$ on sperm motility, normal acrosome, and in-vitro fertilization and culture of pig oocytes matured in-vitro. The sperm-rich fraction (30~60 ml) of ejaculate was collected into an insulated vacuum bottle. Semen was slowly cooled to room temperature (20~23$^{\circ}C$) by 2 h after collection. Semen was transferred into 15 ml tubes, centrifuged at room temperature for 10 min at 800$\times$g, and the supernatant solution was poured off. The concentrated sperm was resuspended with 5 ml of lactose, egg yolk and N-acetyl-D-glucosamine (LEN) diluent to provide 1.0$\times$10$^{9}$ sperm/ml at room temperature. The resuspended semen was cooled in a refrigerator to 4$^{\circ}C$ and preserved for 5 days to examine sperm motility and normal acrosome. The medium used for oocyte maturation was modified tissue culture medium (TCM) 199. After about 22 h of culture, oocytes were cultured without cysteamine and hormones for 22 h at 38.5$^{\circ}C$, 5% $CO_2$ in air. Oocytes were inseminated with liquid boar sperm stored at 4$^{\circ}C$ for 2 days after collection. Oocytes were coincubated for 6 h in 500 ${mu}ell$ mTBM fertilization media with 0.2, 1, 5 and 10$\times$10$^{6}$ /ml sperm concentration, respectively. At 6 h after IVF, oocytes were transferred into 500 ${mu}ell$ Hepes-buffered NCSU-23 culture medium for further culture of 6, 48 and 144 h. There were significant differences in sperm motility and normal acrosome among preservation days and incubation times, respectively. The rates of sperm penetration and polyspermy were higher in 5 and 10$\times$10$^{6}$ sperm/ml than in 0.2 and 1$\times$10$^{6}$ sperm/ml. Male pronuclear formation was lower in 0.2$\times$10$^{6}$ sperm/ml than in 1, 5 and 10$\times$10$^{6}$ sperm/ml. Mean numbers of sperm in penetrated oocyte were highest in 10$\times$10$^{6}$ sperm/ml compared with other sperm concentrations. The rate of blastocysts from the cleaved oocytes (2~4 cell stage) was highest in 1$\times$10$^{6}$ sperm/ml compared with other sperm concentrations. In conclusion, we found out that liquid boar sperm stored at 4$^{\circ}C$ could be used for in-vitro fertilization of pig oocytes matured in-vitro. Also, we recommend 1$\times$10$^{6}$ ml sperm concentration for in-vitro fertilization of pig oocytes.

  • PDF

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Fauna and geographical distribution of house dust mites in Korea (한국내 집먼지진드기의 지역분포상)

  • 이한일;전성후
    • Parasites, Hosts and Diseases
    • /
    • v.35 no.1
    • /
    • pp.9-17
    • /
    • 1997
  • During the period of 1933-1994, house dusts were collected from 65 homes at 10 different localities by operating electric vacuum cleaners. House dust mites were isolated from 10 g dust by applying the modified wet sieving method. Total 7,257 mites were collected and 23 species were identified. Among them, Demctophqgoines loyinaf (DF) was predominant (65. Soy) of the total) , followed by D. pteronvssinus (DP) (20.6%) and Tyrophagus nutrescentios (TP) (6.5%) . Rhizoglvphur robini, Sancqsscnin phvIlophogiann, Cheyletus trcussarti and Scheloribates latipes were the first findings from Korea. DF was predominant in Seoul (66.8%), Kwangju (63.6%), inland of Pusan (79.6%1, Inchon (96.5%), Taejon (83.9%), Chouju (87.15) and Chongiu (95.2%), whereas DP was predominant in Yongkwang-ub (72.5%) and Yongdo (island) of Pusan (64.9%), and TP in Chunchon (38.2%) The localities where DP and TP were predominant showed higher relative humidity in air (> 73% RH) . Among 62 study homes, DF, DP and TP were found in 24.6% of the homes, co-habitat of two species in 48.1% and one species in 27.3%. DF was predominant in 63.5% of the homes studied, DP in 29.6% and TP in 6.9%. In 10 g of the house dust, less than 99 mites were found in 49 homes (70.0%), 100-499 mites in 11 homes (15.7%), 500-999 mites in 3 homes (4.3%) and more than 1,000 mites in 2 homes (2.9%). No mite was found in 5 homes (7.1%). In order to evaluate environmental factors affecting the population density of house dust mites, house type, age of house construction, size of the house, number of the family and frequency of the cleaning were compared with the number of mites, and none of the above factors were statistically correlated with the mite density.

  • PDF

Development of Frequency Weighing Sensor and Single Crystal Growth (새로운 무게센서 재발과 단결정성장(1))

  • Jang Y.N.;Sung N.H.;Chae S.C.;Bae I.K.;Kim I.J.
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1997
  • A new weighing sensor for the automatic diameter control system of the crystal growth is developed in this study. This weighing sensor measures the frequency of the vibrating element which is lineally changing with respect to weight. The signal and the power of this system are transmitted without any physical contact, so that this sensor offers high accuracy and resolution. This system consists of a string, a sinusoidal wave generator, an automatic amplification adjusting circuit, signal transformers and a PCB. 4 kinds of programs are developed for checking DAC, weight calibration and controlling growth process. The measurements of the standard deviation and the resolution show $\pm0.10g$(measured at every second) and $5{\times}10^{-5}$, respectively, This weighing sensor is effective under high pres-sure of 200 atm, high temperature and vacuum condition. The weighing system can control the temperature in the accuracy of $\pm0.025^{\circ}C$ with the 'signal divider'. The optical quality single crystals of $(YGd)_3Sc_2Ga_3O_{12},\;Er-Y_3Sc_2Al_3O_{12},\;and\;Bi_{12}GeO_{20}$ have been grown by Czo-chralski method using this auto-diameter control system.

  • PDF

Follicular Stimulation and Laparoscopic Ovum Pick-up (LOPU) in Repeatedly Superovulated Korean Black Goats (반복적인 과배란 처치 경험이 있는 한국흑염소에서 난포 자극 및 복강경을 이용한 난포란 채취(LOPU))

  • Lee, Yong-Boum;Lee, Doo-Soo;Cho, Sang-Cheol;Shin, Sang Tae
    • Journal of Embryo Transfer
    • /
    • v.29 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Laparoscopic ovum pick-up (LOPU) is a convenient method for collecting oocytes in small ruminants. LOPU has the advantage of being a less invasive means of oocyte collection, thereby allowing for a repeated usage of the oocyte donor animals. A total of 25 Korean black goats were used in the winter season (December to February) and LOPU was applied to the goats which had been treated for superovulation more than two times during the last twelve months. Estrus was synchronized with an intravaginal insert containing 0.3 g progesterone for 10 to 12 days. Ovaries were hyperstimulated with eCG 1,000 IU oneshot, FSH with eCG (50 mg / 1,000 IU; 70 mg / 500 IU; 70 mg / 1,000 IU) oneshot or FSH multiple-shot with eCG oneshot ($20mg{\times}6/300IU$) given intramuscularly 72 h prior to LOPU. For these groups, the number of follicles (mean ${\pm}$ SEM) observed which developed to larger than 2 mm in diameter were $1.6{\pm}2.5$, $4.3{\pm}3.1$, $5.5{\pm}4.2$, $6.6{\pm}2.1$ and $8.8{\pm}7.8$, respectively. Oocytes were aspirated by using OPU needles and a vacuum pump. The overall oocyte retrieval rates were 41.4%. Oocytes were matured in TCM-199 supplemented with 10% (w/v) bovine serum albumin + $10{\mu}g/ml$ FSH + $1{\mu}g/ml$ $17{\beta}$-estradiol for 27 h at $39^{\circ}C$ in 5% $CO_2$ in air. Oocytes were parthenogenetically activated by ionomycin combined with 6-diethylaminopurine (6-DMAP). Total oocyte maturation and cleavage rate were 67.3% and 78.8%, respectively. In summary, LOPU is a useful oocyte collection method in Korean black goats that can provide immature oocytes for transgenesis or nuclear transfer.

Effect of Interlayer on TiN and CrN Thin Films of STS 420 Hybrid-Deposited by AlP and DC Magnetron Sputtering (AIP 와 스퍼터링으로 복합증착된 420 스테인리스강의 TiN과 CrN 박막에 미치는 중간층의 영향)

  • Choi, Woong-Sub;Kim, Hyun-Seung;Park, Burm-Su;Lee, Kyung-Ku;Lee, Doh-Jae;Lee, Kwang-Min
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.256-262
    • /
    • 2007
  • Effects of interlayer and the combination of different coating methods on the mechanical and corrosion behaviors of TiN and CrN coated on 420 stainless steel have been studied. STS 420 specimen were tempered at $300^{\circ}C$ for 1 hr in vacuum furnace. The TiN and CrN thin film with 2 ${\mu}m$ thickness were coated by arc ion plating and DC magnetron sputtering following the formation of interlayer for pure titanium and chromium with 0.2 ${\mu}m$ thickness. The microstructure and surface analysis of the specimen were conducted by using SEM, XRD and roughness tester. Mechanical properties such as hardness and adhesion also were examined. XRD patterns of TiN thin films showed that preferred TiN (111) orientation was observed. The peaks of CrN (111) and $Cr_2N$ (300) were only observed in CrN thin films deposited by arc ion plating. Both TiN and CrN deposited by arc ion plating had the higher adhesion and hardness compared to those formed by magnetron sputtering. The specimen of TiN and CrN on which interlayer deposited by magnetron sputtering and thin film deposited by arc ion plating had the highest adhesion with 22.2 N and 19.2 N. respectively. TiN and CrN samples shown the most noble corrosion potentials when the interlayers were deposited by using magnetron sputtering and the metal nitrides were deposited by using arc ion plating. The most noble corrosion potentials of TiN and CrN were found to be approximately -170 and -70 mV, respectively.