• 제목/요약/키워드: v-ray

검색결과 2,479건 처리시간 0.037초

The Geometrical Isomerization on Acidification in Hexamolybdoheteropoly Oxometalate. The Crystal Structure of $(NH_{4})_{4.5}[H_{3.5}\alpha-PtMo_{6}O_{24}].\;1.5H_{2}O,\;(NH_{4})_{4}[H_{4}\beta-PtMo_{6}O_{24}].\;1.5H_{2}O,\;and\;K_{3.5}[H_{4.5}\alpha-PtMo_{6}O_{24}].\;3H_{2}O$

  • Lee, Uk;Yukiyoshi Sasaki
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.37-45
    • /
    • 1994
  • $(NH_4)_{4.5}[H_{3.5}{\alpha}-PtMo_6O_{24}]{\cdot}1.5\;H_2O(A),\;(NH_4)_4[H_4{\beta}-PtMo_6O_{24}]{\cdot}1.5\;H_2O(B),\;and\;K_{3.5}[H_{4.5}{\alpha}-PtMo_6O_{24}]{\cdot}3\;H_2O(C)$ have been synthesized and their molecular structures have been also determined by single-crystal X-ray diffraction technique. The space groups, unit cell parameters, and R factors are as follows: Compound A, monoclinic, $A_{2/a}$, a= 19.074 (3), b=21.490 (3), c=15.183 (2) ${\AA};\;{\beta}$=109.67 (1) ${\AA}$; z=8; R=0.075($IF_0I>4{\sigma}(IF_0I);$ Compound B, triclinic, P$bar{1}$, a=10.776 (2), b=15.174 (4), c=10.697 (3) ${\AA};\;{\alpha}$ =126.29 (2), ${\beta}$=111.55 (2), ${\gamma}$=93.18 (2) ${\AA}$; Z=2; R=0.046($IF_0I>3{\sigma}(IF_0I);$): Compound C, triclinic, Pl, a=12.426 (2), b=13.884 (2), c=10.089 (1) ${\AA}$; ${\alpha}$=102.59 (2), ${\beta}$=110.73 (1), ${\gamma}$=53.93 (1) ${\AA}$; Z=2; R=0.074 ($IF_0I>3{\sigma}(IF_0I)$. Compounds A and C contain the well-known Anderson structure (planar structure) heteropoly oxometalate having approximate $bar{3}_m(D_{3d})$ symmetry, while compound B contains the bent structure heteropoly oxometalate having appproximate $2_{mm}(C2_v)$ symmetry. The bent structure and the planar one are geometrical isomers. These compounds are rot only novel heteroply molybdates containing platinate(IV) but also the first example of geometrical isomerism in the hexamolybdoheteropoly oxometalates. That isomerization surprisingly occurred because of the change of only 0.5 non-acidic hydrogen atom attached to the polyanion such as $[H_{3.5}{\alpha} -PtMo_6O_{24}]^{4.5-}{\to}[H_4{\beta}-PtMo_6O_{24}]^{4-}{\to}[H_{4.5}{\alpha} -PtMo_6O_{24}]^{3.5-}$. It seems that the gradual protonation of the polyanion plays an important role in that isomerism. These heteropolyanions form dimers by strong hydrogen bonds between two heteropolyanions in the respective crystal system.

Physical Properties of the Nonstoichiometric Perovskite $Dy_{1-x}Sr_xCoO_{3-y}$ System

  • 정수경;김민규;김규홍;여철현
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권9호
    • /
    • pp.794-798
    • /
    • 1996
  • Solid solutions of the nonstoichiometric Dy1-xSrxCoO3-y system with the compositions of x=0.00, 0.25, 0.50, 0.75, and 1.00 have been synthesized by the solid state reaction at 1000 ℃ under atmospheric air pressure. The crystallographic structures of the solid solutions are analyzed by the powder X-ray diffraction patterns at room temperature. The analyses assign the compositions of x=0.00 and 0.25 to the orthorhombic system with space group of Pbnm/D2h16, the compositions of x=0.50 and 0.75 to the tetragonal system like a typical SrCoO2.86, and the composition of x=l.00 or SrCoO2.50 to the brownmillerite type system with space group of I**a. The reduced lattice volumes increase with x value due to the larger radius of Sr2+ ion than that of Dy3+ ion. The mole ratio of Co4+ ion to total Co ion with mixed valence state between Co3+ and Co4+ ions at B sites or τ value has been determined by an iodometric titration. All the samples except for the DyCoO3 compound show the mixed valnce state and thus the composition of x=0.50 has the maximum τ value in the system. The oxygen vacancies increasing with x value are randomly distributed over the crystal lattice except for the composition of x=l.00 which have the ordering of the oxygen vacancies. The nonstoichiometric chemical formulas of the Dy1-xSrxCo3+1-τCo4+τO3-(x-τ)/2 system are formulated from the x, τ, and y values. The electrical conductivity in the temperature range of 100 to 900 K increases with τ value linearly because of positive holes of the Co4+ ions in π* band as a conducting carrier. The activation energy of the x=0.50 as Ea=0.17 eV is minimum among other compouds. Broad and high order transition due to the overlap between σ* and π* bands broadened by the thermal activation is observed near 1000 K and shows a low temperature-semiconducting behavior. Magnetic properties following the Currie-Weiss law show the low to high spin transition in the cobaltate perovskite. Especially, the composition of x=0.75 presents weak ferromagnetic behavior due to the Co3+-O2--Co4+ indirect superexchange interaction.

입상 인공제올라이트를 이용한 중금속 폐수 정화와 벼 유묘 생육장해 경감 (Effect of Artificial Granular Zeolite(AGZ) on Purification of Heavy Metals in Wastewater and Alleviation or Rice Seeding Growth Damage)

  • 이덕배;이경보;이상복;김재덕;테루오 헨미
    • 한국토양비료학회지
    • /
    • 제32권4호
    • /
    • pp.446-451
    • /
    • 1999
  • 입상인공제올라이트의 몇 가지 광물학적 특징을 구명하고 입상인공제올라이트를 이용한 중금속 폐수 정화효과와 벼 유묘 생육장해 경감효과를 분석한 결과는 다음과 같다. 입상인공제올라이트를 X선 회절 분석하면 Na-P1의 피크가 주로 나타났고 포틀랜드 시멘트의 $C_3S$ 피크도 혼재하고 있었다. 입상인공제올라이트는 열 분석 결과 $130^{\circ}C$ 부근 흡열반응피크는 약해졌으나 $750^{\circ}C$부근 흡열반응 피크가 새롭고 깊게 나타났다. 입상인공제올라이트는 합성 폐수중 납 제거능이 가장 우수하였고, 다음으로 구리 카드뮴, 아연 순이었다. 입상인공제올라이트를 광산폐수 대비 1/50량 넣고 1일 이상, 또는 1/100량을 넣고 4일간 정체 처리하면 농업용수 기준에 적합하였다. 광산폐수 중에서 벼 유묘는 뿌리가 잘 자라지 못하여 말라죽었으나, 인공제올라이트로 정화처리수중에는 정상적으로 생육하였다.

  • PDF

PdCu를 전기 도금한 레이저 유도 그래핀 전극 기반의 과산화수소 측정 센서 개발 (Development of a Hydrogen Peroxide Sensor Based on Palladium and Copper Electroplated Laser Induced Graphene Electrode)

  • 박대한;한지훈;김태헌;박정호
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1626-1632
    • /
    • 2018
  • In this paper, we describe the fabrication and characterization of a hydrogen peroxide ($H_2O_2$) sensor based on palladium and copper (PdCu) electroplated laser induced graphene (LIG) electrodes. $CO_2$ laser was used to form LIG electrodes on a PI film. This fabrication method allows simple control of the LIG electrode size and shape. The PdCu was electrochemically deposited on the LIG electrodes to improve the electrocatalytic reaction with $H_2O_2$. The electrochemical performance of this sensor was evaluated in terms of selectivity, sensitivity, and linearity. The physical characterization of this sensor was conducted using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), which confirmed that PdCu was formed on the laser induced graphene electrode. In order to increase the sensor sensitivity, the Pd:Cu ratio of the electroplated PdCu was varied to five different values and the condition of highest amperometric current at an identical of $H_2O_2$ concentration was chosen among them. The resulting amperometric current was highest when the ratio of Pd:Cu was 7:3 and this Pd;Cu ratio was employed in the sensor fabrication. The fabricated PdCu/LIG electrode based $H_2O_2$ sensor exhibited a sensitivity of $139.4{\mu}A/mM{\cdot}cm^2$, a broad linear range between 0 mM and 16 mM of $H_2O_2$ concentrations at applied potential of -0.15 V, and high reproducibility (RSD = 2.6%). The selectivity of the fabricated sensors was also evaluated by applying ascorbic acid, glucose, and lactose separately onto the sensor in order to see if the sensor ourput is affected by one of them and the sensor output was not affected. In conclusion, the proposed PdCu/LIG electrode based $H_2O_2$ sensor seems to be suitable $H_2O_2$ sensor in various applications.

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

"한국수산지" 를 통해 본 1910년경 충남 서해안 지역 수산업에 관한 경제지리학적 고찰 (The Economic-Geographical Consideration of Fisheries of the West Coast Area, Chungnam in the 1910s in "Hangooksusanji")

  • 조창연;김학태
    • 한국경제지리학회지
    • /
    • 제8권1호
    • /
    • pp.153-169
    • /
    • 2005
  • 본 연구에서는 $\ulcorner$한국수산지$\lrcorner$ 를 통한 1910년경 충남의 수산업 현황 및 실태 등을 분석하였다. 분석결과 충남 서해안 지역에는 30개의 포구가 있었으며, 이것들의 입지유형을 5개 유형으로 분류할 수 있었다. I 유형은 중 $\cdot$소하천변에 위치한 포구, II유형은 금강본류 연안의 포구 III유형은 연안에서 외해에 접하고 있는 포구, IV유형은 만내에 입지하는포구, V유형은 연안도서지역의 포구들이다. 어종은 도미, 삼치, 가오리, 조기, 갈치, 새우등이며, 도미어업 근거지는 죽도 및 연도였으며, 조기어장은 전라도 칠산탄에서 충남연해 일대에 형성되었고, 갈치는 전 연안 각처에서 어획되었다. 제염업은 충남 전해안의 만입부에서 이루어졌으며, 대표적 지역은 서천만, 웅천만, 오천만, 안면도, 태안, 당진지역 등이다. 특히 태안군 지역에서 생산된 소금은 태안염이라 불릴 정도로 유명하였다. 금강 연안은 어촌이 32곳 있었으며, 하류지역인 금강구는 뱅어의 중심어장이었다. 비인만 지역은 23곳의 어촌이 있었는데, 어종은 조기, 갈치, 도미, 숭어, 가오리, 상어류, 멸치, 새우, 등을 어획하였다. 보령연해 지역은 33곳의 어촌이 입지하고 있었지만, 제염업이 성하여 어업은 크게 발달하지 못하였다. 천수만 지역은 28곳의 어촌, 태안반도 및 가로림만 연안에는 70여 곳의 어촌, 아산만 지역은 55곳의 어촌이 기록되어 있지만, 이들 지역이 농업을 주로 행하였기 때문에 염업이나 간석지를 중심으로 어전어업 정도가 발달한 정도였다. 서해 도서 지역 중 안면도 남쪽 지역은 주목망 어업이 가장 발달한 해역이었고, 금강 하구의 도서지역은 도미의 중심어장이었다.

  • PDF

CBCT와 EXACTRAC을 이용한 Spine SBRT의 유용성 평가 (A Study to Evaluate the Efficacy of CBCT and EXACTRAC on Spine Stereotactic Body Radiation Therapy)

  • 최우근;박수연;박도근;송기원
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.167-173
    • /
    • 2013
  • 목 적: CBCT와 EXACTRAC을 이용한 Spine 체부정위적방사선 치료 Set up 시 이미지 보정 값과 실제 오차의 차이를 측정하고, 이 오차 값이 미치는 선량분포를 계산하여 CBCT와 EXACTRAC의 유용성을 평가하고자 한다. 대상 및 방법: Set up 오차 보정 값과 실제 오차 비교 실험을 위해서 QA용 Cubic phantom (The EASY CUBEr, Euromechanics, Schwarzenbruck, Germany)을 이용하였고, phantom의 중심축을 인위적으로 LR 방향으로 -1 mm, -2 mm, -3 mm SI 방향으로 1 mm, 2 mm, 3 mm 그리고 AP방향으로 1 mm, 2 mm, 3 mm 이동시켰으며, 중심축을 $0.5^{\circ}$씩 좌우로 회전시켜 CBCT와 EXACTRAC의 Auto matching 보정 값과 비교 측정하였으며, 이동된 오차 값을 가정하여 Rando Phantom을 이용한 Spine SBRT 플랜에 적용하여 재계산을 시행하였다. 결 과: Set up 보정 값과 실제 오차 비교실험에서 3D CBCT의 평균값은 LR, SI, AP 방향으로 0.15 mm 회전방향으로 $0.04^{\circ}$였고 EXACTRAC의 평균값은 LR, SI, AP 방향으로 0.18 mm 회전방향으로 $0.07^{\circ}$였다. 이동 값 오차를 가정한 선량 재계산 결과, SI방향 2, 3 mm 이동 시 $V_{10}$ (종양의 용적에 10 Gy가 들어가는 선량) Volume이 각각 10.574%, 10.712%가 나타났고 LR방향 -3 mm 이동 시 12.076%로 가장 높게 나타났다. 결 론: CBCT와 EXACTRAC의 Set up 보정 값과 실제 오차는 1 mm, $0.1^{\circ}$ 미만으로 두 시스템 모두 매우 정밀한 set up 오차보정을 보였다. 그러나 선량 재계산 시 3 mm 이상의 오차가 발생한 경우, Spine SBRT 치료 시 Spinal cord에 들어가는 선량이 $V_{10}$에서 3% 이상 최대선량 13 Gy 이상 증가함으로서 치명적인 흡수선량 오류가 발생할 수 있음을 확인하였다. 따라서 본 저자는 1회에 한한 Spine SBRT 치료 시 정확도 측면에서 종양의 단면 정보를 위치적으로 제공하는 CBCT가 더 유용할 것으로 사료된다.

  • PDF

전기도금을 이용한 스테인레스 스틸 선재의 직경 증가에 관한 실험적 연구 (An experimental study on diameter increase of orthodontic wire by electroplating)

  • 조진형;성영은;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제33권2호
    • /
    • pp.121-130
    • /
    • 2003
  • 본 연구는 전기도금을 이용하여 교정용 선재의 직경을 증가시킨 후 그 물성 변화를 알아봄으로써 이의 임상적 적용 가능성을 알아보고자 시행되었다. 0.016 인치 스테인레스 스틸 교정용 선재에 전기도금을 위한 적절한 전처리를 시행한 후, 황산 니켈 100g/L, 염화니켈 60g/L, 붕산 30g/L, 염화나트륨 50g/L의 조성을 가지는 전해액을 제조하여 1.7V의 전압과 $25\~29^{\circ}$의 온도, $3.1\~3.3pH$의 조건 하에서 직경을 0.002 인치 증가시켜 0.018 인치 직경의 선재로 만들었다 전기도금 과정 중 1분 단위로 직경을 측정하여 시간에 따른 직경 증가율을 구하였고, 도금 후 서로 다른 세 지점의 직경을 계측하여 균일성을 평가하였으며, 도금 금속의 정성분석을 위하여 X-선 회절검사를 시행하였다. 도금층의 밀착성 증진을 위해 $400^{\circ}$의 전기로에서 10분간 열처리를 시행한 후 도금 전후와 열처리 전후의 물성 변화를 알아보기 위하여 3점 굴곡 실험을 시행하여 다음과 같은 결과를 얻었다. 1.전반적인 하중-변형률 곡선을 보면 0.016인치 군과 0.018인치 군 사이에 도금 처리한 군이 존재하였으며 열처리한 경우가 0.018 인치 군에 더욱 가까워지는 양상을 보였다. 2. 도금에 이해 지경은 0.002이차 증가시킨 군이 기존의 0.016이차 군에 비하여 강성과 항복강도 극한강도 모두 증가하는 경향을 보였으며 이중 강성과 극한 강도는 통계적으로 유의한 차이를 보였다. 3. 0.016인치에서 도금에 의해 직경을 0.002인치 증가시킨 군이 기존의 0.018인치 군보다 강성과 항복강도, 극한강도 모두에서 낮게 나타났으며 통계적 유의차를 보였다. 4. 도금 후 열처리를 시행한 군이 시행하지 않은 군보다 강성, 항복강도, 극한강도 모두 높은 경향을 보였으며, 극한강도에서 유의한 차이를 나타내었다. 5. 전기도금 후 서로 다른 세 지점의 직경차이는 $0.1\~0.3\%$로 균일하게 나타났으며 통계적으로도 유의차가 존재하지 않았다.

3차원 속도 토모그래피를 이용한 북한지역의 지각구조 연구 (Study of Crustal Structure in North Korea Using 3D Velocity Tomography)

  • So Gu Kim;Jong Woo Shin
    • 지질공학
    • /
    • 제13권3호
    • /
    • pp.293-308
    • /
    • 2003
  • 북한 지역 60km 하부 지각구조에 관한 새로운 결과를 토모그래피 방법으로 연구하였다. 한반도와 주변에서 얻어진 1013개의 P파와 S파 주행시간이 사용된다. 또한, 이 연구에서 토모그래피 알고리즘에 의해서 모든 지진의 진원이 재결정 된다. 속도구조의 파라미터화는 지진파 밀도에 따라 분포된 Node에 의해서 결정된다. 4개 Level의 120 Node가 각각 P파와 S파의 속도 구조에 적용된다. 연구 결과로 깊이 8Km의 량림 육괴의 깊이에서 P파와 S파 속도 이상변화는 각각 높고 낮게 나타났다. 그 반면에 평남분지의 P파와 S파 속도는 24km 깊이까지 모두 낮게 나타났다 그것은 량림 육괴는 지하수나 온천 등으로 포화 된 단층 및 파쇄대를 많이 갖고 있는 시생대-초기 하부 원생대육괴로 되어 있고, 반면에 평남분지의 평양-사리원 일대는 상부 원생대, 실루리안, 상부 고생대와 하부 중생대 기원의 퇴적층으로 채워진 내부 플렛트 폼 함몰로 되어 있음을 의미한다. 특히 백두산 하부 8, 16. 24km 깊이에서 높은 P파와 5파의 속도이상은 고결된 마그마 물체의 천부 도랑일지 모른다. 그러나 38km에서 낮은 P파와 S파 속도이상은 용융상태의 저속도 마그마방과 관련 된 것으로 본다. 우리는 또한 사리원을 포함한 옹진 분지에서 Moho불연속면이 약 55km임을 발견하였다. 백두산의 모호불연속면은 38km가량 된다. 특히 백두산 Moho에서 V/sub p//V/sub s/의 높은 비율은 지각과 맨틀 경계에서 용융물체가 있는것으로 간주된다. 또한 본 연구는 또한 량림육괴 순상지(Shield)의 끝 가장자리인 묘향산 지역 하부 40km에서 매운 높은 P파와 S파 속도 구조를 갖는 물체가 있음을 보여 주었다.

다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구 (A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field)

  • 김주호;이상규;신현경;이석;나수경;조정희;김동욱
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.155-160
    • /
    • 2005
  • 목 적 : 전산화단층 모의치료조준(CT simulation)과 선량 계획 장비(RTP)의 발전으로 많은 저자들에 의해 종양부 위의 선량을 증가시키고 인접한 장기의 선량을 효과적으로 감소시킬 수 있는 3차원 입체 조형 치료(Conformal therapy)와 조사면내 선량 보강 기법(Field in field technique)이 자주 소개되어지고 있다. 이러한 치료 기법은 많은 수의 조사면을 사용함으로써 조사면이 증가할수록 10 MU이하의 극히 적은 기계적 입력치(monitor unit, MU)를 사용하기도 한다. 통상 일반적으로 사용되어지는 선량에 대한 정보(beam data)는 이보다 훨씬 많은 100 MU이상 혹은 그보다 높은 안정적인 출력을 기대할 수 있는 상태에서 측정되어지므로 극히 적은 기계적 입력치에서도 기존에 측정되어진 선량 정보와 동일한 선량분포를 구현할 수 있는지 반드시 확인하여야 한다. 따라서 본 연구에서는 극히 적은 기계적 입력치(MU)에서의 선량적 안정성을 알아보고 향후 정도 관리지침에 활용코자 한다. 대상 및 방법 : 본원에서 사용 중인 선형가속기 Varian 2100C/D의 6 MV, 10 MV(USA)와 Varinan 600C의 4 MV(USA)의 에너지를 사용하여 $10{\times}10cm^2$ 조사면에서 90 MU를 90 MU, 45 MU, 30 MU, 18 MU, 9 MU, 6 MU로 각각 1, 2, 3, 5, 10, 15 회씩 나누어 조사하였다. 전리함(pinpoint farmer type chamber, PTW, GERMANY)를 이용하며 4 MV, 6 MV는 5 cm, 10 MV는 10 cm 깊이, SAD 100 cm에서 물 팬텀을 이용하며 조사면내의 출력을 측정하였고, 측정용 필름(X-omat V, Kodak, USA)을 이용하며 높은 선량을 나타내는 90 MU, 30 MU에서의 편평도와, 대칭도를 비교하였고 일반적인 medical film(AGFA USA)을 이용하여 낮은 선량을 보이는 9MU에서 조사면내 편평도와, 대칭도를 비교하여 선질의 특성 변화를 관찰하였다. 결 과 : 전리함을 이용한 측정에서 2100C/D는 90 MU와 9 MU에서 1 MU 당 선량(cGy/MU)은 6 MV와 10 MV에서 90 MU를 1회에 조사한 것과 비교하여 약 1.6% 정도 증가하였고 2100C는 0.5%, 1.3%가 각각 증가하였다. 600C 또한 1.6% 증가하였으나 6 MU에서 약 3% 차이를 나타내었다. 편평도와 대칭도는 장비와 에너지에 따라 1%에 2.9%까지 차이가 있었으나 전체적으로 적은 MU에서 약간 더 균등하였고 극히 적은 MU로 인한 차이는 확인할 수 없었다. 결 론 : 각각의 실험에서 선량적 차이는 허용되어지는 범위이하의(출력<3%, 편평도<${\pm}3%$, 대칭도<2%, ICRU report 50)오차를 모임으로써 보유한 장비에 따라 정도에 차이는 있을 수 있으나 본원에서 사용 중인 장비에서 극히 적은 MU의 사용이 현저한 선량적 오차를 유발하진 않는 것으로 사료되어진다. 그러나 정도 관리 시 그 오차를 확인하는 과정은 장비의 사용과 수명에 따라 지속적으로 관리되어져야 할 것이다.

  • PDF