• 제목/요약/키워드: v/c

검색결과 13,377건 처리시간 0.039초

1200V급 4H-SiC DMOSFET 성능지수 최적화 설계 시뮬레이션 (A simulation study on the figure of merit optimization of a 1200V 4H-SiC DMOSFET)

  • 최창용;강민석;방욱;김상철;김남균;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.63-63
    • /
    • 2009
  • In this work, we demonstrate 800V 4H-SiC power DMOSFETs with several structural alterations to observe static DC characteristics, such as a threshold voltage ($V_{TH}$) and a figure of merit ($V_B^2/R_{SP,ON}$). To optimize the static DC characteristics, we consider four design parameters; (a) the doping concentration ($N_{CSL}$) of current spreading layer (CSL) beneath the p-base region, (b) the thickness of p-base ($t_{BASE}$), (c) the doping concentration ($N_J$) and width ($W_J$) of a JFET region, (d) the doping concentration ($N_{EPI}$) and thickness ($t_{EPI}$) of epi-layer. Design parameters are optimized using 2D numerical simulations and the 4H-SiC DMOSFET structure results in high figure of merit ($V_B^2/R_{SP,ON}$>~$340MW/cm^2$) for a power MOSFET in $V_B{\sim}1200V$ range.

  • PDF

디아미노안트라퀴논계 분산염료/모노클로로트리진형 반응염료에 의한 폴리에스테르/면 혼방 직물의 날염 (Printing of Polyester and Cotton Blends using Diaminoanthraquinone Disperse Dye and Monochlorotriazinyl Reactive Dye Mixtures)

  • 강숙녀
    • 한국염색가공학회지
    • /
    • 제6권2호
    • /
    • pp.30-39
    • /
    • 1994
  • To study the printing behaviors of Polyester and cotton(P/C) fabrics printed with disperse and reactive dyes, the effects of alkalis on the fixation of reactive dyes and the alkali-stability of disperse dyes in various methods of fixation were examined. The anthraquinone disperse dyes which have diamino derivatives as substituents without hydroxy group, such as C.I. Disperse Violet 1(D.V.1), C.I. Disperse Violet 28(D.V.28) and C.I.Disperse Blue 60(D.B.60) showed good results of fixation without regard to the concentration of NaHCO$_3$. In case of high temperature steaming(HTS) and unsaturated steaming(US)/HTS, D.V. 1 was alkali-stable and effective for P/C printing. A good result was obtained with D.V.1 and C.I.Reactive Orange 13(R.O.13) paste of 4% $K_{2}CO_{3}$. It was found that the unfixed D.V.28 bearing chloro group can hinder the fixation of monochlorotriaxinyl reactive dyes, and D.B.60 made little stain on 100% cotton. In thermosol(Tm), the dye uptake of D.V.1 was not decreased so much, but those of D.V.28 and D.B.60 were greatly decreased.

  • PDF

$28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성 (Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$)

  • 홍현권;김규태;박세일;김구현;남두우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.

Flame-holder를 장착한 Dump Type Ram-combustor의 연소성능 향상에 관한 연구 (A Study on the Improvement of Combustion Performance in Dump type Ram-combustor Equipped for Flame-holder)

  • 이대웅;윤현진;문수연;손창현;이충원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제16회 학술발표회 논문초록집
    • /
    • pp.43-46
    • /
    • 2001
  • Dump type Ram-combustor의 성능 개선을 위한 화염 안정화 장치인 V-gutter를 장착하고 그 영향을 파악하기 위한 본 실험에서 V-gutter가 없고, Ram-combustor의 길이가 짧을 경우($L_c$=300mm)에는 출구중앙의 온도가 감소하는 경향이 나타났고 Ram-combustor의 길이가 증가하면($L_c$=500mm) 중앙에서 온도가 감소되는 현상은 나타나지 않지만 화염은 아직도 Ram-combustor의 아래 부분에 치우쳐있다. V-gutter가 장착된 경우 Ram-combustor 출구의 온도 분포는 훨씬 균일하게 분포되었다. 그리고 Ram-combustor의 길이가 짧을 때($L_c$=300mm) 연소효율의 경우 V-gutter을 장착한 경우 연소효율은 약간 증가하지만 큰 영향은 없음을 알 수 있다.

  • PDF

Si 기판위에 증착한 SrTiO$_3$ /PbTiG$_3$ 고용체 박막의 구조적 특성 및 C-V 특성 (Structural and C-V characteristics of SrTiO$_3$ /PbTiO$_3$ thin film deposited on Si)

  • 이현숙;이광배;김윤정;박장우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.71-74
    • /
    • 2000
  • Pt/Pb$TiO_3$/$SrTiO_3$/p-Si films were prepared by metallo-organic solution deposition(M0SD) method and investigated its structure and ferroelectric properties. Crystallinity of specimen as a funtions of post annealing temperature and the thickness of $SrTiO_3$(STO) buffer layer was studied using XRD and AFM. Based on C-V and P-E curve, $PbTiO_3$(PTO) capacitors showed good ferroelectric hysteresis arising from the polarization switching properties. When the thickness of ST0 buffer layer between PTO and Si substrate was 260 nrn and the post annealing temperature was $650^{\circ}C$, it was showed that production of the pyrochlore phase due to interdiffusion of Si into FTO was prevented. The dielectric constant of FTO thin films calculated from a maximum Cma in the accumulation region was 180 and the dielectric loss was 0.30 at 100 kHz frequency. The memory window in the C-V curve is 1.6V at a gate voltage of 5V.

  • PDF

Molecular Cloning, Bioinformatics Analysis and Expression Profiling of a Gene Encoding Vacuolar-type $H^+-ATP$ Synthetase (V-ATPase) c Subunit from Bombyx mori

  • Lu, Peng;Chen, Keping;Yao, Qin;Yang, Hua-Jun
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제15권2호
    • /
    • pp.115-122
    • /
    • 2007
  • As the genome of B.mori is available in GenBank and the EST database of B.mori is expanding, identification of novel genes of B.mori is conceivable by data-mining techniques. We used the in silico cloning method to get the vacuolar-type $H^+-ATP$ synthetase (V-ATPase) c subunit (16 kDa proteolipid subunit) gene of B.mori and analysed with bioinformatics tools. The result was confirmed by RT-PCR and sequencing. The V-ATPase c subunit cDNA contains a 468 bp ORF. The ORF encoded a 155-residue protein that showed extensive homology with V-ATPase c subunits from other 15 species and contained four membrane-spanning helices. Tissue expression pattern analysis revealed that V-ATPase c expressed strongly in Malpighian tubules, not in fat body. This gene has been registered in GenBank under the accession number EU082222.

ICP-CVD로 성장된 SiC박막의 Ni 금속 접합과 Ni/SiC Schottky diode의 특성 분석 (Characteristics of Ni metallization on ICP-CVD SiG thin film and Ni/SiC Schottky diode)

  • 길태현;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.938-940
    • /
    • 1999
  • We have fabricated SiC Schottky diode for high temperature applications. SiC thin film for drift region has been deposited by ICP-CVD. In order to establish metallization conditions, we have extracted the device parameters of the Schottky diode from the forward I-V characteristics and the C-V characteristics as a function of temperature. The ideality factor was varied from 2.07 to 1.15 and the barrier height was also varied from 1.26eV to 1.92eV with increase of temperature. The reverse blocking voltage was 183 V.

  • PDF

황의 Sublimatographic Characters에 관한 연구 (Study on the Sublimatographic Characters of Sulfur)

  • 손진언;김주봉
    • Elastomers and Composites
    • /
    • 제7권1호
    • /
    • pp.53-58
    • /
    • 1972
  • Sublimatographic study on the method of test for sulfur in the petroleum and rubber products was as following results: (1) The relation between the heating temperature$(t_h)$ and the vacuum condensing point(V.C.P.) of sulfur at different degree of vacuum appeared as Fig.4. The results were in good agreement with those expected from the $t_h-V.C.P$ curves of sublimatographic separation of sulfur. (2) The relation between the degree of vacuum and the V.C.P. at different heating temperature of sulfur appeared as follows; $$tv.c.p.=\alpha+{\beta}logP_{va}$$ (3) The V.C.P of sulfur could be physical property comparing with melting point and boiling point. (4) The relation between the V.C.P. and the quantity of sublimation of sulfur becomes quantitative as Fig.7.

  • PDF

뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가 (The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery)

  • 이두상;강효석;최병준;박상준;정다이;이건호;안민우;전명수
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.9-16
    • /
    • 2018
  • 목 적 : 뇌 정위적 방사선수술은 외과적 수술로 인한 합병증 발생 비율이 높은 질환을 비침습적으로 치료할 수 있다. 하지만 뇌 정위적 방사선수술은 방사선을 이용하기 때문에 분할방사선치료와 같이 방사선에 의한 부작용을 동반할 수 있다. 두경부 등의 분할방사선치료 시 방사선에 의한 부작용을 줄이기 위해 Coplanar Volumetric Modulated Arc Therapy(C-VMAT)와 Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT)가 주변 정상조직에 미치는 영향에 대한 분석이 이루어졌지만, 뇌 정위적 방사선수술에서는 이러한 내용들이 분석되지 않았다. 본 연구에서는 뇌 정위적 방사선수술을 실시한 환자를 대상으로 C-VMAT과 NC-VMAT을 비교, 분석하여 NC-VMAT의 유용성을 평가하고자 한다. 대상 및 방법 : 뇌 정위적 방사선수술 13건을 대상으로 하였으며, C-VMAT, NC-VMAT 치료 계획을 진행하였다. 치료 계획 용적은 최소 0.78 cc에서 최대 12.26 cc의 용적을 가지고 있었으며, 처방 선량은 15~24 Gy가 처방되었다. 치료 장비는 trueBEAM Stx(Varian Medical Systems, USA)을 사용하였으며, 치료 계획에 사용된 에너지는 6 MV Flattening Filter Free(6FFF) X-선을 이용하였다. C-VMAT 치료계획은 half 2 Arc 또는 full 2 Arc를 사용하여 치료계획을 진행했으며, NC-VMAT 치료계획은 $40{\sim}190^{\circ}$의 Arc를 3~7개 사용하고, couch의 각도 또한 3~7개의 각도로 구성하여 치료계획을 진행하였다. 결 과 : 최대선량의 평균 값은 C-VMAT에서 $105.1{\pm}1.37%$로 나타났으며, NC-VMAT에서는 $105.8{\pm}1.71%$로 나타났다. C-VMAT의 처방 선량 지수(Conformity index)는 $1.08{\pm}0.08$로 나타났고, 선량 균질 지수(Homogeneity Index)는 $1.03{\pm}0.01$로 나타났다. NC-VMAT의 처방 선량 균질지수는 $1.17{\pm}0.1$, 선량 균질지수는 $1.04{\pm}0.01$로 나타났다. 뇌의 $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$는 C-VMAT에서 $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$, $4.03{\pm}3.43cc$로 나타났으며, NC-VMAT에서는 $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$로 나타냈다. 결 론 : 최대선량과 처방 선량 지수, 선량 균질 지수 항목에서는 C-VMAT과 NC-VMAT이 큰 차이를 보이지는 않았다. 뇌의 선량 당 용적은 $V_2{\sim}V_{18}$까지 구간에서 값의 차이는 최소 0.5 %에서 최대 48 %의 차이가 나타냈다. $V_{19}{\sim}V_{24}$까지 구간에서 값의 차이는 최소 0.4 %에서 최대 4.8 %의 차이가 나타냈다. 방사선괴사(Radionecrosis)가 발생하기 시작하는 $V_{12}$ 용적의 평균 값을 비교해본 결과 NC-VMAT 이 C-VMAT 대비 약 12.2 % 적은 용적을 포함하는 것을 알 수 있었다. 이러한 결과로 볼 때 NC-VMAT 치료 계획을 수립한다면, $V_2{\sim}V_{18}$의 용적을 줄일 수 있기 때문에 방사선괴사를 줄일 수 있을 것이라 사료된다.

  • PDF

부자(附子)가 Lipopolysaccharide의 뇌실 주입으로 유발된 생쥐의 혈중 IL-6와 $TNF-{\alpha}$ 변화에 미치는 영향 (Effects of Aconiti Tuber on the Change of Interleukin-6 and $TNF-{\alpha}$ Level induced by LPS I.C.V. Injection in Mice)

  • 고동균;윤정문;이태희
    • 대한한의학방제학회지
    • /
    • 제12권1호
    • /
    • pp.195-208
    • /
    • 2004
  • Objective: This study was conducted to investigate the effects of Aconiti Tuber on the plasma IL-6 and $TNF-{\alpha}$ level in mice stimulated by intracerebroventricular(I.C.V.) Injection of Lipopolysaccharide(LPS). Method: 6 mice were assigned to each of the normal group, the control group, and the experimental group. In the normal group only saline was administered intragastrically, and in the control group LPS was injected intracerebro-ventricularly 1 hr after intragastric administration of saline. In the experimental groups (Aconiti Tuber 0.5g/kg, Aconiti Tuber 1.0g/kg, Aconiti Tuber 3.0g/kg) each sample was administered intragastrically to mice 1 hr prior to the stimulation by LPS I.C.V. Injection. To measure the plasma IL-6 and $TNF-{\alpha}$ level of mice, their blood samples were collected from retro-orbital plexus, immediately centrifuged at $4^{\circ}C$, and plasma was removed and stored frozen at $-83^{\circ}C$ for later determination of plasma IL-6 and $TNF-{\alpha}$. Result : 1. LPS I.C.V. Injection increased plasma IL-6 level significantly in a dose-dependent manner compared with normal group(P<0.01). The plasma IL-6 concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). LPS I.C.V. Injection increased plasma $TNF-{\alpha}$ level significantly in a dose-dependent manner(P<0.05). The plasma $TNF-{\alpha}$ concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). 2. Sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma IL-6 level in 1 hr than control group(P<0.0635), and sample B group (Aconiti Tuber 1.0g/kg) showed significant lower plasma IL-6 level in 1 hr than control group(P〈0.05), and sample C group (Aconiti Tuber 3.0g/kg) showed significant lower IL-6 plasma level in 1 hr than control group(P<0.01). 3. sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma $TNF-{\alpha}$ level in 1 hr than control group(P>0.05), and Both sample B(1.0g/kg) and sample C(3.0g/kg) groups showed significant lower $TNF-{\alpha}$ plasma level in 1 hr than control group(P<0.01). These data revealed that Aconiti Tuber might have the anti inflammatory effect by reducing the plasma IL-6 and $TNF-{\alpha}$ level in a dose dependent manner in mice LPS I.C.V. Injection.

  • PDF