• Title/Summary/Keyword: utilization of CT equipments

Search Result 8, Processing Time 0.019 seconds

A study on the utilization of CT equipments (전산화 단층촬영 장치의 이용 실태에 대한 조사)

  • Cho, Pyong-Kon;Oh, Yu-Whan;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • This study was conducted to investigate the patient exposure dose during a CT examination and the present position in utilization of the CT equipments. To this end Questionnaire were sent out to 278 medical facilities registered at Korea Hospital Association and replies of 161 medical facilities were analyzed. The results were as follows ; 1) The distribution of CT examination was. Brain 40.7%, Abdomen 27.8%, Chest 15.7%, Spine 4.8%, Pelvis 4.1%, PNS 3.2%, Facial bone 2.5% and Extremity 1.1% respectively. 2) The statistics for dose index according to each part of examination were Brain 38.0mGy, Abdomen 12.0mGy for adults : Brain 13.6mGy, Abdomen 6.2mGy for infant. Our surveyed dose index appeared lower than the IAEA recommends. 3) Most medical facilities have selected the parameters for radiographic exposure in the range of $100{\sim}120kVp,\;100{\sim}250mA\;and\;1{\sim}2$ seconds.

A Study on the Status and Utilization of Computed Tomography Units in Pusan Area (전산화(電算化) 단층촬영기(斷層撮影機)의 보유현황(保有現況) 및 이용실태(利用實態) (부산시내(釜山市內) 병원(病院)을 중심(中心)으로))

  • Oh, Moon-Young
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.29-44
    • /
    • 1991
  • A Study on the distribution and types of the total 40 CT units, as of 1st October 1990, in Pusan area(29 for whole body CT units, 11 for brain CT units) were carried out during the period from January 1989 to December 1989 to find out the status of operation and utilization of whole body CT units. The results were as following ; 1. As of 1st October 1990 in Pusan area, a total of 40 CT units(29 for whole body CT units, 11 for brain CT units) were set up and operated. The number of cases of CT examination performed per day per unit were appeared to be less than 5 cases among 59.5% of CT units, and 2.7% of the total units has peformed more than 16 examinations. 2. The CT units under operation occupied 93.5% of the total and 2.6% of the total units was not properly been operated due to mechanical breakdown. This results is appeared to be better than other reports. 3. The average number of scanning per week for each CT were 35 cases and the average days under operation of the unit per week were 6.7 days. Consequently, the average days under operation of units was higher than that of the other reports, but the average number of scanning was lower. 4. The cases referred from other institutes to hospitals were 6.4% of total cases. 5. As a site of scanning, the brain appeared most frequently with 71.2% of the total cases and followed by spine 12.4%, abdomen 8.5%, and thorax 3.6%, respectively. 6. Positive rate by scanning was 70.8% of total cases, and it was 98.9% with thorax, abdomen 96.3%, spine 93.1%, and brain 38.4%, respectively. According to the results of this study, it is highly recommended that the regulations and the guidelines for setting-up of such high cost medical equipments as CT units be provided in order to ensure the cost-effectiveness of the system.

  • PDF

3-D Inverse Radon Transform by Use of Tree-Structured Filter Bank

  • Morikawa, Yoshitaka;Murakami, Junichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.184-187
    • /
    • 2002
  • Two-dimensional (2-D) X-ray computerized tomography (CT) equipments are widely used in industrial and medical fields, and nowadays studies on reconstruction algorithm for 3-D cone-beam acquisition systems are active for better utilization. The authors recent-By have proposed a fast reconstruction aigorithm using tree-structured filter bank for 2-D C1, and shown the algorithm is applicable to an approximate reconstruction of 3-D CT. For exact 3-D CT reconstruction, however, we have to backproject 1-D signal into 3-D space. This paper proposes a fast implementation method for this back-projection by use of tree-structured filter bank. and shows the proposed method works approximately 700 times faster than the direct one with almost same reconstruction image quality.

  • PDF

Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area (비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用))

  • Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

A Study on the Socio-economic Characteristics of Magnetic Resonance Image(MRI) Uses in Korea (우리나라 MRI 이용의 사회경제적 특성)

  • 김루시아;문옥륜
    • Health Policy and Management
    • /
    • v.2 no.2
    • /
    • pp.194-220
    • /
    • 1992
  • In recent years there has been a rapid influx of high cost MRI equipment into Korea. This diffusion has raised concerns about the changes it will bring for the health care utilization. Therefore, the purpose of this study is to identify socio-economic characteristics of MRI uses in Korea. A structured questionnaire was designed for this purpose, and 1, 091 users were surveyed at the 35 MRI units of 33 hospitals during a week, sometimes March 1992. The study reveals that high cost technology such as MRI, CT scanner is so prevalent in Korea. This is particularly the case in metropolitan areas. Among others, Seoul has the highest percentage of MRI equipment, 51.05%, Pusan 12.10% and Kwangju 11.9%. Unfortunately, most high cost technology equipments are foreign products. Thus, hospitals with such a high cost technology have difficulties in maintenance of the equipment. The average performance of MRI equipment has declined from 10.2 cases per day in 1988 to 7.16 cases in March 1992. Due to the rapid increase, the performance of MRI equipment seems to be deterioration. Male usere are dominant in the case of MRI use. The utilization rate has positively increased with the rise of educational level of users. The same is true for the level of income; the MRI utilization rate by income level shows that it is negatively proportional to income, which indicates that the poor have difficulties in the use of high cost technology. Particularly, the cost of MRI is so high that ordinary patients are unable to pay for it. For example, 86.3% of respondents have answered that the cost is too high even though they are insured by health insurance. This is the first empirical study on the use status of MRI. The information obtained in this study is sufficient to maintain that the Korean health insurance programme is urgently in need of improving the insurance benefit schemes. The easiest way to do this is to include provision of high cost technology service into the benefit package.

  • PDF

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Development of a Hospital Service-based Costing System and Its Application (병원서비스별 원가분석모형의 개발과 적용)

  • 박하영
    • Health Policy and Management
    • /
    • v.5 no.2
    • /
    • pp.35-69
    • /
    • 1995
  • The managerial environment of hospitals in Korea characterized by low levels of medical insurance fees is worsening by increasing government regulations as to the utilization of medical services, rising costs of labor, material, and medical equipments, growing patient expectations concerning the quality of services, and escalating competitions among large hospitals in the market. Hospitals should seek for their survival strategies in this harsh environment and they should have information about costs of their products in doing so. However, it has not been available due to the complexity of the production process of hospital services. The objectives of this study were to develop a service-based cost accounting model and to apply the developed model to a study hospital to obtain cost information of hospital services. A model commonly used for the job-order product cost accounting in the manufacturing industry was modified for the use in hospitals in Korea. Actual costs, instead of standard costs, incurred to produce a unit of services during a given period of time were estimated in the model. Data required to implement the model included financial information, statistics for the allocation of supportive cost center costs to final cost centers, statistics for the allocation of final cost center costs to services, and the volume of each services charged to patients during a study period. The model was executed using data of a university teaching hospital located in Seoul for the fiscal year 1992. Data for financial information, allocation statistics fo supportive service costs, and the volume of services, most of them in electronic form, were available to the study. Data for allocation statistics of final cost center costs were collected in the study. There were 15 types of evaluation and management service, 2, 923 types of technical service, and 2, 608 types of drug and material service charged to patients in the study hospital during the fiscal year 1992. Labor costs of each of seven types of pesonnel, material costs of 611 types of drugs and materials, and depreciation costs of 212 types of medical equipments, miscellaneous costs, and indirect costs incurred in producing a unit of each services were estimated. Medical insurance fees for basic services such as evaluation and management of inpatients and outpatients, injection, and filling prescriptions, and for operating procedures were found to be set lower than costs. Infrequent services which use expensive medical equipments showed negative revenuse as well. On the other hand, fees for services not covered by the insurance such as CT, MRI and Sonogram, and for laboratory tests were higher than costs. This study has a significance in making it possible for a hospital to obtain cost information for all types of services which produced income based on all types of expenses incurred during a given period of time. This information can assist the management of a hospital in finding an effective cost reduction strategy, an efficient service-mix strategy under a given fee structure, and an optimum strategy for within-hospital resource allocations.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.