• 제목/요약/키워드: user-interfaced design

검색결과 11건 처리시간 0.022초

Skin-interfaced Wearable Biosensors: A Mini-Review

  • Kim, Taehwan;Park, Inkyu
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.71-78
    • /
    • 2022
  • Wearable devices have the potential to revolutionize future medical diagnostics and personal healthcare. The integration of biosensors into scalable form factors allow continuous and noninvasive monitoring of key biomarkers and various physiological indicators. However, conventional wearable devices have critical limitations owing to their rigid and obtrusive interfaces. Recent developments in functional biocompatible materials, micro/nanofabrication methods, multimodal sensor mechanisms, and device integration technologies have provided the foundation for novel skin-interfaced bioelectronics for advanced and user-friendly wearable devices. Nonetheless, it is a great challenge to satisfy a wide range of design parameters in fabricating an authentic skin-interfaced device while maintaining its edge over conventional devices. This review highlights recent advances in skin-compatible materials, biosensor performance, and energy-harvesting methods that shed light on the future of wearable devices for digital health and personalized medicine.

Bluetooth를 이용한 VOIP Phone 의 Wireless LAN Access System 개발 (Design and Implementation of a Bluetooth LAN access system for VoIP phone)

  • 김정근;김영덕;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.343-346
    • /
    • 2002
  • This paper presents a Prototype system developed for a Bluetooth interfaced VoIP system. The VoIP phone is developed based on tile implementation of a CELP coder on the TI 16bit DSP Processor A PC interfaced with Bluetooth module is used to designing a access point system. Host controller protocol stack is implemented to realize gateway between the wireless and wired line networks. A server application program for user management and call processing, which is based on TCP/IP peer to peer connection, is implemented for tile evaluation of overall interface system.

  • PDF

역할 기반 변동 보안 룰셋 적용을 위한 네트워크 보안 게이트웨이 설계에 관한 연구 (A Study on the Design of the Security Gateway for Role-based Dynamic Security Rule-Set)

  • 이춘재;조기량
    • 한국통신학회논문지
    • /
    • 제33권8B호
    • /
    • pp.719-726
    • /
    • 2008
  • 본 논문에서는 보안 게이트웨이가 서브넷 상의 단말기의 네트워크 접근 시도 시에 해당 단말기를 자동으로 인식하여 단말기 사용자의 인증 및 접근 제어 보안 룰셋을 기간 데이터베이스와 비교 판별하여 동적으로 조직 내의 역할 기반 접근 권한을 부여, 관리하는 방식에 대해 연구하였다. 덧붙여, 네트워크 관리자가 조직 구조와 관련하여 네트워크 레벨(L2)과 어플리케이션 레벨(L7)의 통합 액세스 제어를 지정할 수 있도록 사용자 중심의 권한 부여 모델을 제시하였다.

문화적 사용자 인터페이스 디자인을 위한 방법론 개발에 관한 연구-웹 브라우저의 활용을 중심으로- (Development of Design Methodology for Cultural user-Interface Design: with the Emphasis on the Application of web-browser)

  • 이건표
    • 디자인학연구
    • /
    • 제11권1호
    • /
    • pp.73-80
    • /
    • 1998
  • 최근 들어 그 중요성이 더욱 증대되기 시작한 문화적 디자인은 주로 형태나 색채 등의 현상적 연구에만 머물고 있는 형편이다. 보다 본질적인 문화적 디자인을 이루기 위해서는 이러한 현상적 연구와 함께 제품과의 상호작용의 특성과 같은 문화적 사용자-인터페이스 디자인에 대한 연구가 이루어져야 할 것이다. 이에 본 연구는 이러한 문화적 사용자 인터페이스 디자인을 위한 방법론 개발이 일환으로 웹 브라우저를 통한 사용 성 연구를 제안한다. 본 연구는 우선 문화의 정의, 깊이, 문화 변수 등을 살펴봄으로써 문화의 본질적 성격을 이해하고, 이를 바탕으로 타 문화권 사용자들이 제품을 사용할 때 나타나는 행위 특성을 연구할 수 있는 방법의 구조를 설정하였다. 이어서 이 구조를 근거로 하여 타 문화권의 사용자들이 직접 WWW 상에서 접근하여 제품을 사용하게 한 후 이를 분석할 수 있는 사용 성 평가 프로그램을 개발하였다. 이는 사용자의 인구 통계적 사항을 조사하는 모듈, 사용자의 문화변수별 특성을 파악하는 모듈, 사용자의 스테리오타잎을 조사하는 모듈, 제품을 직접 사용하여 사용 성을 평가하는 모듈, 마지막으로 모든 인터랙션 데이터를 기록하고 문자로 저장하여 다양한 통계를 이룰 수 있는 분석 모듈 등으로 나뉘어 구성되었다. 끝으로 본 연구이 한계를 지적하고 이의 향후 연구방향을 제시하였다.

  • PDF

범용 전문가시스템 쉘을 이용한 선박의 구조설계 지원 시스템 (A Design Support System for the Structural Design of Ships Based on an Expert System Development Shell)

  • 한순홍;이경호;이동곤;김은기;이규철
    • 대한산업공학회지
    • /
    • 제19권2호
    • /
    • pp.83-93
    • /
    • 1993
  • Conventional computer programs developed and used by practicing engineers can be considered to contain expert knowledge and design experience. If these conventional programs are converted into expert systems, the difficult and time consuming process of knowledge acquisition can be simplified. Also the constructed knowledge-base can have higher confidence level than that constructed by the usual knowledge acquisition method of interviews. An existing computer program which is being used by ship structural designers has been reformulated as a design expert system by applying an expert system development shell-Nexpert. Utilizing the callable interface provided by the development shell, external design tools have also been integrated. The interfaced external functions are a graphical user interface (GUI) for the design process control, and graphics functions for the visualization of design results. It is observed that the developed system for design support is useful in two aspects. The trace-back function shows what portion of design rules are applied in arriving at certain design decisions. Also the knowledge-base can be conveniently updated as design rules of the classification societies are updated.

  • PDF

UHF 대역 무선 프린터 공유 인터페이스의 설계 (The Design of Wireless Printer Interfaces for UHF band)

  • 강영석;김기래
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 춘계종합학술대회
    • /
    • pp.280-283
    • /
    • 2000
  • 여러 대의 컴퓨터를 사용하는 경우 프린터의 공유 방법에 관한 문제가 제기된다. LAN에 의한 프린터공유는 보편적이나, LAN이 설치되지 않은 환경에서는 프린터 공유기를 이용하거나 프린터를 이동시켜 인쇄를 하여야 한다. 본 연구에서는 컴퓨터와 프린터 사이에 무선으로 데이터를 송수신 한 수 있는 무선 인터페이스 프린터 공유기를 개발하였다. 이 장치를 이용함으로써 프린터의 이동 없이 최대 50미터 반경내의 다수의 컴퓨터와 시분할 방식의 공유가 가능하다. 본 장치는 프린터와 컴퓨터에 UHF 송수신 인터페이스 모듈을 각각 설치하여 데이터를 전송하며, 최대 전송속도는 9600bps이다.

  • PDF

동력전달용 치차설계 전문가 시스템 개발연구 II (Development of Expert System for Designing Power Transmission Gears (II))

  • 정태형;변준형;이동형
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.122-131
    • /
    • 1992
  • 본 연구에서는 동력전달용 치차설계 전문가 시스템을 구축하기 위한 일단의 연구로서 먼저 동력전달용 치차의 치차파손의 원인과 대책의 진단을 위한 전문가 시스 템을 개발하였으며, 본 논문에서는 치차의 강도를 기준으로 삼아 원통치차를 설계할 수 있는 강도 기준 치차설계 전문가 시스템을 개발한다. 즉, 전문가 시스템은 치차 설계에 필요한 지식을 체계적으로 지식 베이스에 구축하며, 이를 이용하여 새로운 설 계안을 도출해 낼수 있는 추론엔진을 구성하고, 설계광정중에 변화하는 설계의 중간결 과 등을 저장하기 위한 임시작업영역을 기본요소로 구축한다. 또한 과거의 설계예를 데이터 베이스로 구축하여 설계시에 참조 할 수 있도록 하며, 새로운 치차의 설계뿐아 니라 설계되어 있는 치차의 강도평가도 할 수 있도록 한다. 전문가 시스템에 사용자 인터페이스, 설명기능, 지식획득기능 등을 추가함으로써 치차분야에 초심자라 할지라 도 개발된 전문가 시스템과의 문답식 대화를 통하여 손쉽게 치차를 설계할 수 있도록 한다.전문가 시스템을 기술하는 프로그램 언어는 PROLOG를 사용하여 퍼스널컴퓨 상 에서 구동될 수 있도록 하며, 강도평가시 많은 수치계산이 필요한 부분은 FORTRAN언어 를 사용하여 기술한 후 PROLOG와 연결(interface)함으로써 전체 전문가 시스템을 구축 한다.

휴대용 유도탄 체계의 모델링과 성능분석을 위한 실시간 병렬처리 시뮬레이터 (Real-time Parallel Processing Simulator for Modeling Portable Missile System and Performance Analysis)

  • 김병문;정순기
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.35-45
    • /
    • 2006
  • 본 논문에서는 휴대용 회전 유도탄 체계의 모델링과 성능분석에 사용할 수 있는 실시간 병렬처리 시뮬레이터 개발에 대하여 기술한다. 실시간 병렬처리 시뮬레이터는 항공기의 적외선 형상을 만드는 탐색기 에뮬레이터, 실시간 컴퓨터, 시스템 유닛. 유도 조종 장치 및 탐색기 프로세서 등과 같은 하드웨어 실물장치와 실시간 컴퓨터에 내장된 수학적 모델, 6 자유도 모델 및 공력 모델 등을 구현한 응용 소프트웨어 및 호스트 컴퓨터에 내장된 사용자 프로그램 등으로 구성되었다. 실시간 컴퓨터는 병렬로 연결된 여섯 개의 TI사 C-40 프로세서로 설계되었으며, 기계적 장치와 결합된 아날로그 전자회로를 이용하여 탐색기 에뮬레이터를 설계하였다. 시스템 유닛은 구성 요소간의 임피던스 정합 기능과 미세 신호를 처리하며, 시뮬레이터와 실물 유도탄 발사 장치의 연결이 가능하다. 개발된 실시간 병렬처리 시뮬레이터를 휴대용 회전 유도탄의 성능분석 장치로 사용하기 위하여 현장실험을 통한 결과 검증시험을 수행하였다.

  • PDF

멀티 GNSS 보정시스템을 위한 BeiDou 의사거리 보정기법 (Method of BeiDou Pseudorange Correction for Multi-GNSS Augmentation System)

  • 서기열;김영기;장원석;박상현
    • 한국정보통신학회논문지
    • /
    • 제19권10호
    • /
    • pp.2307-2314
    • /
    • 2015
  • 본 논문에서는 위성항법시스템(Global Navigation Satellite System, GNSS)의 다양화에 따른 위성항법보정시스템(Differential GNSS, DGNSS) 기준국 설계를 위하여, 중국 위성항법시스템인 BeiDou의 의사거리 보정정보 생성 알고리즘과 시뮬레이션 기반의 성능 검증에 대해 중점적으로 다룬다. 먼저 DGNSS 기준국/감시국(Reference Station and Integrity Monitor, RSIM)에서의 국제적 표준 및 요구성능에 대해 살펴보고, BeiDou 연동제어문서(Interface Control Document, ICD)를 기반으로 위성의 위치를 추정하고 위성시계 옵셋과 사용자 수신기의 시계오차, 그리고 GPS(Global Positioning System)와 BeiDou 위성의 시스템 타임 옵셋을 계산하여 BeiDou 의사거리 보정정보(Pseudorange Correction, PRC)를 생성한다. GPS/BeiDou 시뮬레이터를 연동한 성능검증 플랫폼을 기반으로 BeiDou 보정정보의 오차를 계산하고, 그 측위정확도를 분석하여 성능검증을 수행하였다. 실험결과 BeiDou 의사거리 보정정보가 RTCM(Radio Technical Commission for Maritime Services)에서 요구하는 기준국 운영 및 보정서비스를 위한 측위성능을 충족함을 확인하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF