• Title/Summary/Keyword: use of radiation

Search Result 2,085, Processing Time 0.037 seconds

The Activity Check of Brachytherapy Isotope (근접치료동위원소의 Activity Check)

  • Kim, Gun-Oh;Lee, Byung-Koo;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ${\pm}2.1\%$. (which belongs to recommendable value for AAPM ${\pm}5\%$ as difference of error range) It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  • PDF

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Changes of Smoke Components and Smoke Odor by Far Infra-red Radiation in a Closed Room

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.198-204
    • /
    • 1998
  • This study was conducted to evaluate the effect of far IR radiation for the elimination of sidestream smoke components in a closed room. The measurements covered particle sizes of 13.8-542.5 nm, particle concentration, TSP, UVPM, FPM, solanesol, and the following gases and vapor components of smoke: carbon dioxide, carbon monoxide, nicotine, and 3-ethenyl-pyridine. Also, the changes of smoke odor strength by far IR radiation were tested by using the electronic nose system. There was no difference between control and far IR radiation in changes of the concentration of $CO_2$ and CO. The concentrations of TSP, UVPM, FPM, solanesol, nicotine, and 3-ethenylpyridine were reduced by far IR radiation. The growth and diminishing rate of RSP diameter was accelerated by far IR radiation compared with control. There was a little difference of smoke odor change with far IR radiation by electronic nose system analysis. Our results indicated that the use of far IR radiation had a little effect on changes of solid, vapor, and odor of smoke, but it had no effect on gaseous components.

  • PDF

Post Pelvic Radiotherapy Bony Changes (골반 방사선 치료후의 골 변화와 손상)

  • Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • There has been recent interest in radiation-induced bone injury in clinical conditions, especially for pelvic insufficiency fracture (PIF). A PIF is caused by the effect of normal or physiological stress on bone with demineralization and decreased elastic resistance. Pelvic radiotherapy (RT) can also contribute to the development of a PIF. A PIF has been regarded as a rare complication with the use of megavoltage equipment. However, recent studies have reported the incidence of PIFs as $8.2{\sim}20%$ after pelvic RT in gynecological patients, an incidence that was higher than previously believed. The importance of understanding a PIF lies in the potential for misdiagnosis as a bony metastasis. If patients complain of pelvic pain after whole-pelvis radiation therapy, the presence of a PIF must be considered in the differential diagnosis. The use of multibeam arrangements and conformal RT to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture. In addition to a PIF, osteonecrosis and avascular necrosis of the femoral head can develop after radiation therapy. Osteoradionecrosis of the pelvic bone is a clinical diagnostic challenge that must be differentiated from an osseous metastasis. A post-radiation bone sarcoma can result as a long-term sequela of pelvic irradiation for uterine cervical cancer.

A Study on the Estimating Solar Radiation Using Hours of Bright Sunshine for the Installation of Photovoltaic System in Korea (국내 태양광시스템 설치지역을 위한 일조시간에 의한 일사예측에 관한 연구)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heac
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.72-79
    • /
    • 2011
  • Solar radiation data are the best source of information for estimating average incident radiation. Lacking this or data from nearby locations of similar climate, it is possible to use empirical relationships to estimate radiation from days of hours of bright sunshine. It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. Therefore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account hours of bright sunshine. Particularly, the proposed straight line regression model shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of -0.2 to +0.5% and each station annual average deviation of -1.6 to +1.7% from measured values.

Provision of a Draft Version for Standard Classification Structure for Information of Radiation Technologies through Analyzing Their Information and Derivation of Its Applicable Requirements to the Information System (방사선 기술정보 분석을 통한 정보표준분류체계(안) 마련 및 시스템 적용요건 도출)

  • Jang, Sol-Ah;Kim, Joo Yeon;Yoo, Ji Yup;Shin, Woo Ho;Park, Tai Jin;Song, Myung-jae
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • Radiation technology is the one for developing new products or processes by applying radiation or for creating new functions in industry, research and medical fields, and its application is increasing consistently. For securing an advanced technology competitiveness, it is required to create a new added value by information consumer through providing an efficient system for supporting information, which is the infrastructure for research and development, contributed to its collection, analysis and use with a rapidity and structure in addition to some direct research and development. Provision of the management structure for information resources is especially crucial for efficient operating the system for supporting information in radiation technology, and then a standard classification structure of information must be first developed as the system for supporting information will be constructed. The standard classification structure has been analyzed by reviewing the definition of information resources in radiation technology, and those classification structures in similar systems operated by institute in radiation and other scientific fields. And, a draft version of the standard classification structure has been then provided as 7 large, 25 medium and 71 small classifications, respectively. The standard classification structure in radiation technology will be developed in 2015 through reviewing this draft version and experts' opinion. Finally, developed classification structure will be applied to the system for supporting information by considering the plan for constructing this system and database, and requirements for designing the system. Furthermore, this structure will be designed in the system for searching information by working to the individual need of information consumers.

Sinonasal teratocarcinosarcoma treated with surgery followed by volumetric modulated radiotherapy: a case report with review of literature

  • Tandon, Sarthak;Gairola, Munish;Ahlawat, Parveen;Sharma, Kanika;Barik, Soumitra;Sachdeva, Nishtha;Pasricha, Sunil;Shenoy, Apeksha
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.341-347
    • /
    • 2018
  • Surgical excision along with use of postoperative radiotherapy forms an integral management of sinonasal teratocarcinosarcoma (SNTCS). However, given the rarity of the tumor, no standardised guidelines, dose, technique and target delineation exist especially in the era of modern radiation delivery techniques. This is a case of 55-year-old male diagnosed as SNTCS treated with radical ethmoidectomy followed by volumetric modulated radiotherapy, showing good local control and acceptable toxicity profile.

Novel biological strategies to enhance the radiation therapeutic ratio

  • Kim, Jae Ho;Jenrow, Kenneth A.;Brown, Stephen L.
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.172-181
    • /
    • 2018
  • Successful anticancer strategies require a differential response between tumor and normal tissue (i.e., a therapeutic ratio). In fact, improving the effectiveness of a cancer therapeutic is of no clinical value in the absence of a significant increase in the differential response between tumor and normal tissue. Although radiation dose escalation with the use of intensity modulated radiation therapy has permitted the maximum tolerable dose for most locally advanced cancers, improvements in tumor control without damaging normal adjacent tissues are needed. As a means of increasing the therapeutic ratio, several new approaches are under development. Drugs targeting signal transduction pathways in cancer progression and more recently, immunotherapeutics targeting specific immune cell subsets have entered the clinic with promising early results. Radiobiological research is underway to address pressing questions as to the dose per fraction, irradiated tumor volume and time sequence of the drug administration. To exploit these exciting novel strategies, a better understanding is needed of the cellular and molecular pathways responsible for both cancer and normal tissue and organ response, including the role of radiation-induced accelerated senescence. This review will highlight the current understanding of promising biologically targeted therapies to enhance the radiation therapeutic ratio.

Development of Radiation Dosimeter on P Channel Power MOSFET for $\gamma$-rays Real-Time Detection ($\gamma$선 실시간 검출을 위한 P채널 Power MOSFET 방사선 선량 시스템 개발)

  • Han, Sang-Hyun;Ji, Yong-Kun;Kwon, O-Sang;Min, Hong-Ki;Lee, Eung-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.213-223
    • /
    • 2000
  • It is necessary that radiation dose would be detect exactly generated from facility related to nuclear, space, radiotherapy center, etc. This paper is to use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Commercial P Channel Power MOSFET(metal oxide field effect transistor) were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial P Channel Power MOSFET as inexpensive radiation sensors.

  • PDF

Solar Radiation Estimation Technique Using Cloud Cover in Korea (운량에 의한 일사예측 기법)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.232-235
    • /
    • 2011
  • Radiation data are the best source of information for estimating average incident radiation. Lacking this or data from nearby locations of similar climate, it is possible to use empirical relationships to estimate radiation from days of cloudiness. It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. There fore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account cloud cover. Particularly, the straight line regression model proposed shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of-0.26 to +0.53% and each station annual average deviation of -1.61 to +1.7% from measured values.

  • PDF