Changes of Smoke Components and Smoke Odor by Far Infra-red Radiation in a Closed Room

  • Published : 1998.12.01

Abstract

This study was conducted to evaluate the effect of far IR radiation for the elimination of sidestream smoke components in a closed room. The measurements covered particle sizes of 13.8-542.5 nm, particle concentration, TSP, UVPM, FPM, solanesol, and the following gases and vapor components of smoke: carbon dioxide, carbon monoxide, nicotine, and 3-ethenyl-pyridine. Also, the changes of smoke odor strength by far IR radiation were tested by using the electronic nose system. There was no difference between control and far IR radiation in changes of the concentration of $CO_2$ and CO. The concentrations of TSP, UVPM, FPM, solanesol, nicotine, and 3-ethenylpyridine were reduced by far IR radiation. The growth and diminishing rate of RSP diameter was accelerated by far IR radiation compared with control. There was a little difference of smoke odor change with far IR radiation by electronic nose system analysis. Our results indicated that the use of far IR radiation had a little effect on changes of solid, vapor, and odor of smoke, but it had no effect on gaseous components.

Keywords