• Title/Summary/Keyword: use frequency

Search Result 6,745, Processing Time 0.03 seconds

Dynamic Analysis of Mechanical Joint Parameters Using the Variation of Frequency Response Function (주파수응답함수의 변화를 이용한 기계적 결합부의 동특성 파라미터 해석)

  • 강성구;지태한;유원희;박영필
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.155-161
    • /
    • 1994
  • The dynamic behavior of a complex mechanical structure can be identified by dividing the structure into a series of smaller structure, called sub- structure and by studying the dynamic characteristics of these components. Generally, the dynamic characteristics of mechanical structure are strongly affected by the properties of joint parameters. In this paper, to identify the dynamic characteristics of mechanical structure, and experimental identification method in which directrly measured frequency response function(FRF) is used is considered. The method does not use the procedure of complex matrix calculation but use that of real matrix calculation. To confirm this method, computer simulation is performed by using frequency response function mixed with noise, and the experimental study is performed about the simple structure. The dynamic characteristics of joint parameters and identified more accurately than in using the prcedure of complex matrix calculation.

  • PDF

Use of Common Verb Phrases in Describing Everyday Activities by Advanced Korean-speaking Learners of English

  • Lee, Jin-Kyong
    • English Language & Literature Teaching
    • /
    • v.13 no.2
    • /
    • pp.109-127
    • /
    • 2007
  • As an attempt to investigate the use of common verbs by a small group of Korean college students at the advanced level, the present study describes the students' speech production data collected from picture description tasks. The primary focus of the data description was how the students used high-frequency verbs in describing everyday activities. Out of total 442 units, 149 verbs were erroneously used. All erroneous utterances were classified into four categories according to their characteristics. The most prominent error type was overgeneralization due to incomplete knowledge of lexical items. Results showed that verbs used in everyday life were not easy even for the advanced level students. Although in some cases, L1 influence was discerned, the students' problems are more fundamental. In particular, the data revealed lack of knowledge of collocational possibilities and restrictions, and confusion about semantic boundaries between verbs which have similar semantic areas. The findings suggest that teaching at the advanced level should take contrastive approaches intralingually as well as interlingually to the high-frequency verbs.

  • PDF

A Design Study of the Local Oscillator System for Millimeter Wave Band (밀리미터파 대역 국부발진 시스템 설계연구)

  • 이창훈;김광동;한석태;정문희;김효령;제도흥;김태성
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.77-80
    • /
    • 2003
  • We design the local oscillator system of the 100 GHz band radio receiving system for a cosmic radio observation. We use the YIG oscillator with digital driver which is the main oscillator. This oscillator has a good frequency and phase stability at some temperature variation, and the easy computer aided control characteristics. This total system designed to two subsystem, first is the oscillator system include YIG oscillator, tripler, harmonic mixer and triplexer etc., second is the PLL system to supply the precise and stable local oscillator frequency to mixer. The proposed local oscillator system in this paper can be use a single or multi pixel receiver because this system can be lock the local oscillator frequency automatically using PC.

  • PDF

On the use of numerical models for validation of high frequency based damage detection methodologies

  • Aguirre, Diego A.;Montejo, Luis A.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.383-397
    • /
    • 2015
  • This article identifies and addresses current limitations on the use of numerical models for validation and/or calibration of damage detection methodologies that are based on the analysis of the high frequency response of the structure to identify the occurrence of abrupt anomalies. Distributed-plasticity non-linear fiber-based models in combination with experimental data from a full-scale reinforced concrete column test are used to point out current modeling techniques limitations. It was found that the numerical model was capable of reproducing the global and local response of the structure at a wide range of inelastic demands, including the occurrences of rebar ruptures. However, when abrupt sudden damage occurs, like rebar fracture, a high frequency pulse is detected in the accelerations recorded in the structure that the numerical model is incapable of reproducing. Since the occurrence of such pulse is fundamental on the detection of damage, it is proposed to add this effect to the simulated response before it is used for validation purposes.

The Effects of Hand-Arm Vibration on Flexor and Extensor Fatigue (전완(前腕)의 국부(局部) 진동(振動)이 작업자의 굴근(屈筋) 및 신근(伸筋) 피로(疲勞)에 미치는 영향)

  • Lee, Dong-Chun;Kim, Gil-Ju
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.55-69
    • /
    • 1999
  • It is very common to use the powered hand tools to enhance the productivity in various types of industry. But the use of the powered hand tools could cause health problems such as cumulative trauma disorders and vibration white fingers. In this study. the effects of hand-arm vibration and anatomical hand position on localized muscle fatigue were analyzed. Eight healthy male subjects volunteered for the study. Vibration frequencies of 0, 40, 80, 100, 150, and 200Hz and hand position of flexion and ulnar deviation were selected for the independent variables of the experiment. Median frequency shifting was used as a dependent variable. The results indicated that at the vibration frequency of 40Hz and accelation of 2g, the muscle fatigue was the greatest. For the hand position. there was significant difference between neutral and flexion. and neutral and ulnar deviation, but no difference between flexion and ulnar deviation. These results could be applied in designing powered hand tools to minimize the health problems.

  • PDF

A Study on New Geoelectric Survey and Instrumentation Using Low Frequency Electric Field Sensing Antenna (저주파 Electric Field Sensing Antenna를 이용한 새로운 탐사 및 계측에 관한 연구)

  • 배명수;여영호;손수국
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper has been studied a new geoelectric survey and instrunmentation using Low Frequency Electric Field .sensing Antenna. “Low Frequency Electric Field Sensing” is a technology in new method of survey to use array type antenna, the power of operation in antenna is using AC or DC pulse instead of DC current. The architecture of system embodied transceiver system using a microprocessor(PIC) of Microcllip Technology Inc. An array antenna design and il control transmission of antenna to use CDMA in this system. It is using array type antenna for the earth、earth's crust to survey explain from theory and experience.

  • PDF

A Study on the Output Noise Reduction of 3-Phase Multilevel Inverter (3상 멀티레벨 인버터 출력노이즈 저감에 관한 연구)

  • Kim, Soo-Hong;Jin, Kang-Hwan;Kin, Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.101-103
    • /
    • 2007
  • Since they use the low switching frequency in multilevel inverter systems, they generate the high low frequency harmonic components. Generally, LC filter is used at the output terminal of inverter systems to solve this problem. But it causes a voltage drop at the output terminal by use of damping resistors, and causes the problem in which system efficiency decreases due to power loss of the damping resistor. In this paper, we proposed an output filter design method for NPC three-level inverter systems with low switching frequency. And we analyzed the efficiency of the proposed filter system, and the effectiveness of the proposed system is verified by simulation and experimental results.

  • PDF

Construction of high frequency B-H Analyzer. (고주파 교류 자기특성의 컴퓨터 계측시스템 제작)

  • Kim, Ki-Uk;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1170-1172
    • /
    • 1996
  • Analog-digital converter boards for use in personal computers have recently being improved markedly, many kinds of high speed(1 MHz - 10 MHz sampling rale) and over 12-bit vertical resolution A/D boards released. It can be applicable to high frequency magnetic measurements. In measurement of magnetic properties of high frequency, digitizing oscilloscope or trasient recorder are being used. but, those price are often expensive, we constructed PC controlled A-C B-H loop tracer that can measure Bs, Br, He, permeability and may be applied about 100 Hz - 20 kHz range. it use IBM PC compatible 1 M Sample/s, 12 bit A/D converter board with SSH(Simultaneous Sample and Hold).

  • PDF

Frequency of Humidifier and Humidifier Disinfectant Usage in Gyeonggi Provine

  • Jeon, Byoung-Hak;Park, Young-Joon
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.2.1-2.4
    • /
    • 2012
  • Objectives: This study is a cross-sectional study to investigate the frequency of humidifier and humidifier disinfectant usage in the general population. Methods: A questionnaire was applied to 94 subjects (46 male, 48 female) from the general population of Gyeonggi Province. The questionnaire consisted of 3 scales (general characteristics, 5 items about humidifier usage, 5 items about humidifier disinfectant usage). Results: Thirty-five (37.2%) of the 94 subjects use a humidifier and humidifier disinfectant usage was found to be 18.1%. The frequency of humidifier usage is 4.8 times per a week and the humidifier disinfectant usage is 2.4 times per a week. Humidifier usage rate was highest in January. and then tended to rise gradually from October. Conclusions: Although this study population was not representative, we can say that approximately 50 percent of the humidifier users use a humidifier disinfectant and the trend of using a humidifier has shown seasonality.

The Forecd Vibration Analysis using Transfer Matrix(I) : Immersed Infinite Circular Cylindrical Shell (전달 행렬을 이용한 진동 및 방사소음 해석 (I) : 무한 원통형 몰수체)

  • 정우진;신구균;전재진;이헌곤
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.443-449
    • /
    • 1994
  • In the analysis of circular cylindrical shell's vibration and sound radiation, there are numerical and analytical methods. Numerical methods such as F.E.M and B.E.M, have the limit of frequency range. Analytical method can be applied to the circular cylindrical shell from low frequency to high frequency. In this paper, we use the analytical method for shell, and numerical method, F.D.M, for fluid. We also use the method using transfer matrix and eigenanalysis of transfer matrix which can therefore calculate the rotational d.o.f that is very imkportant in synthesis with inner structure. Inner structure has much effect on the submerged circular cylindrical shell vibration and sound rediation. Results for the immersed circular cylindrical shell vibration and sound radiation are compared with the analytic solutions.

  • PDF