• Title/Summary/Keyword: use condition

Search Result 5,796, Processing Time 0.037 seconds

Classification of stator coil degradation of traction motor by PD signal distribution analysis (PD 분포 분석에 의한 견인전동기 고정자 코일의 열화도 분류에 관한 연구)

  • Park, Seong-Hee;Lim, Jong-Ho;Jang, Dong-Uk;Park, Hyun-June;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1183-1186
    • /
    • 2004
  • Degradation and insulation failure of traction motor depend on the continuous stress imposed on it. And knowing on insulation condition is important thing for safety operation of EMU(electric multiple unit). In this paper, PD(partial discharge) characteristics for degradation analysis of stator coil is studied. For PD data acquisition, two models are made; one is normal condition coil, the other is aged condition coil. And PD data for discrimination were acquired from PD detector. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different discharge sources. And also these parameter is applied to classify PD sources by neural networks. Neural Networks has good recognition rate for degradation of stator coil.

  • PDF

Pharmacodynamics of Potassium Channel Opener Lemakalim in the Isolated Rat Hearts and Conscious SHRs under Hyperkalemic and Hypokalemic Condition (칼륨채널 활성물질 Lemakalim의 고칼륨혈증 및 저칼륨혈증에서의 심기능에 대한 영향 및 항 고혈압작용)

  • 신홍섭;신화섭;권광일
    • YAKHAK HOEJI
    • /
    • v.37 no.5
    • /
    • pp.463-475
    • /
    • 1993
  • Pharmacological effects of lemakalim on cardiovascular system were investigated using isolated rat hearts and conscious SHRs subjected to hyperkalemic and hypokalemic condition. In the isolated hearts perfused with normal physiological salt solution(4.7 mM KCI), lemakalim increased cardiac function and coronary flow, and these effects were significantly potentiated under hypokalemic(1.2, 2.5 mM KCI), but attenuated under hyperkalemic(IO mM KCI) condition. In conscious SHRS, lemakalim(0.1, 0.2, 0.3mg/kg, p.o.) produced a dose-related decrease in systolic blood pressure, the maximal hypotensive effect being reached around 0.5 hr after dosing. The intensity and the duration of hypotensive effect of lemakalim were significantly increased when administered in combination with dihydrochlorothiazide (2 mg/kg, p.o.), but decreased with triamterene(32 mg/kg, p.o.). It appears that the differential effects of two types of diuretics on the hypotensive action of lemakalim are due to their hypokalemic and hyperkalemic action, respectively. It is conclued that the concomitant use of $K^{+}$ channel openers and hypokalemic diuretics may be an appropriate model of combination therapy in the treatment of hypertension.

  • PDF

User Needs of Women with Pes Planus in Their 50s and 60s for Compression Pants Development (50~60대 평발 여성의 컴프레션 팬츠 개발을 위한 착용자 필요 조사)

  • Lee, Sojung;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.420-432
    • /
    • 2017
  • This study examined user needs for compression pant development for women with pes planus in their 50s and 60s. A total of 355 women aged 50 to 69 participated in the survey and interview. Questions were asked if they had pes planus, the using condition of foot orthotic, inconveniences during gait, and wearing condition of compression pants. The results showed that 42 (11.8%) women had pes planus. Orthotic insole and arch support were used most frequently. The most uncomfortable aspect of foot orthotic (n=146) was that it was difficult to use unless they were going outside. Participants with pes planus responded that they felt discomfort on the inner area of propodium, metatarsus, ankle, and knee during gait. The purchase and wearing rate of compression pants were not high; however, compression pants were purchased with specific needs and purposes. Respondents mainly wore the compression pants for sports activities. M size was the most frequently worn size. They preferred high waist type leggings and there was a need to increase the compression strength of the waist, thigh, knee and ankle. Additionally, the ease of donning and doffing were discussed.

An Econometric Study of Job Aspiration Effect on the Job Satisfaction using Korean Working Condition Survey (직무열망이 직무만족에 미치는 영향)

  • Lee, Jaehee;Lim, Sung-Jun;Park, Jinbeak
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2020
  • The purpose of this study was to measure the job aspiration and examine the relationship between that and job satisfaction for wage-earners using the fourth Korean Working Conditions Survey(KWCS). We use the stochastic frontier model for measuring the job aspiration and testing its effect on the job satisfaction. Fstochastic frontier model is introduced to explain that each company potentially produces less than it might due to a degree of job aspiration, measured by decomposing the residuals. In this model framework, it can be regard that the upper bound of the job satisfaction is the ideal frontier, and the bias between the ideal condition and the reality is the job aspiration. If this concept is applicable to the job aspiration, we can measure this bias and investigate a relationship with the job satisfaction. We find that there exists the job aspiration, and it is significantly negatively correlated with the job satisfaction. This result supports that if job aspiration increases, job satisfaction level decreases.

Mechanical and Durability Characteristics of Latex Modified Repair Mortar for Agricultural Underwater Concrete Structure (수중에 노출된 농업용 콘크리트 구조물 보수용 라텍스개질 모르타르의 역학적 특성 및 내구성능 평가)

  • Won, Jong-Pil;Lee, Jae-Young;Park, Chan-Gi;Sung, Sang-Kyung;Kim, Wan-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.4
    • /
    • pp.35-41
    • /
    • 2007
  • The most agricultural concrete structures for the irrigation and drainage are exposed to the underwater condition at the irrigation period and they take the influence on very severe cold in the winter. Therefore, it is impossible to use repair materials used to the general concrete structures. The research need the development of the repair material for a performance enhance of the agricultural underwater concrete structures. This research evaluated the mechanical and durability performance of the latex modified repair mortar for underwater concrete structures which peformed the repair in the underwater according to the characteristic of the agricultural concrete structure. The latex modified repair mortar is a material that minimize the effect of the ecosystem, environment and the segregation. In this research, the construction condition of the latex modified repair mortar for agricultural concrete structures was considered and the test specimens made in the underwater condition. Test results was then compared with target performance and commercial repair mortar. Experimental test results indicated that the mechanical and durability performance of latex modified repair mortar for agricultural underwater concrete structure satisfied all target performance. Also, the latex modified repair mortar resulted in better repair performance than the commercial repair mortar.

Experimentally Minimized Contaminative Condition of Carbonaceous Artifacts in Transmission Electron Microscope (투과전자현미경에 타소질 불순물의 오염 최소화를 위한 실험 조건)

  • Kim, Young-Min;Choi, Joo-Hyoung;Song, Kyung;Kim, Yang-Soo;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.73-77
    • /
    • 2009
  • Contaminative artifacts such as carbonaceous materials on carbon-coated microgrids are unavoidable, which is induced by electron beam exposure inside electron microscopes. This phenomenon raise a source to produce confusing information to the samples investigated by analytical TEM, which should be alleviated as much as possible. As experimental precautions for reducing this unwanted effect, the use of $LN_2$ cooled anti-contaminator and pre-illumination of electron beam at low magnification can be helpful. Nevertheless, we should be cautious to set an illumination condition for microanalysis because the contaminative effect is dependent with the types of irradiation situations, which is well known to be a decisive factor for causing the carbonaceous artifacts. Accordingly, it is necessary that optimal illumination to minimize the contaminative effect should be selected for improving the accuracy of microanalysis. In this paper, we introduce the practical method to determine the optimal illumination condition by evaluating the contaminative effect as a function of instrumental spot size, which is directly linked with electron current density.

An Analysis on Influence of Geographical Variation Induced by Development Affecting to the Local Scale Wind Environment - Numerical Simulation using the Envi-met Model - (개발에 따른 지형변화가 국지 바람장에 미치는 영향 분석 - Envi-met 모형을 이용한 수치모의 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Lee, Hwa-Woon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.888-903
    • /
    • 2006
  • This study analyze the change of wind pattern and intensity according to the transform of surface conditions, such as land use and height of terrain, over the leeward region. In order to do this, we have employed 'Envi-met' microscale atmospheric numerical model. When the same wind condition is considered, the wind speed of base case having natural surface condition of Chunsudae shows the weakest strength among different cases such as the 'bare case' and the '20 m case' which the plants is removed and the height of terrain is flatted as 20 m above the sea level over the Chunsudae, respectively. The weakening of wind speed is a maximum of $4{\sim}8 m/s$ when the inflow wind speed is 55 m/s.

A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer (비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구)

  • Seon, Yun-Suk;Kim, Jin-Seong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

A Plan to Ensure Safety of Electrical Installation in Empty Houses by Measuring Zero Phase Current (영상전류 측정을 이용한 부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Bae, Seok-Myung;Kim, Young-Seok;Park, Chee-Huyn;Kim, Gi-Hyun;Cho, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.196-201
    • /
    • 2006
  • A electrical fault that may generate an electrical disaster is defined as any abnormal condition caused by reduction in the insulation strength. To find out the abnormal condition, periodical inspections have being performed every 3 years. Recently, the number of empty houses during normal working hours is rising by dramatic increase in the number of nuclear families and double income families. To define the potential risk of the electric installation, measurement of zero phase current has been being considered. But the measured value could not be adapted to an absolute reference to the installation because the measured zero phase current value also contained capacitive leakage current. Therefore, in this paper, the correlation between the condition of the electrical installation and the zero phase current was analyzed. The result focuses on to detect them in a cost efficient way.

Analysis of Heating Energy in a Korean-Style Apartment Building 3 : The Effect of Room Condition Settings (한국형 아파트의 난방에너지 분석 3 :실내설정조건의 영향)

  • Park, Yoo-Won;Yoo, Ho-Seon;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.722-728
    • /
    • 2005
  • The present paper deals with heating energy estimation in Korean-style apartments, paying special attention to the effect of room condition settings. Two types of heating modes are considered: continuous single-zone and scheduled multi-zone. In the latter, zones during unoccupied periods remain unconditioned. Also analyzed are sensitivities in heating energy with respect to the air change rate and the set temperature. The energy use is estimated with TRNSYS 15, a dynamic load calculation program. Heating energy for the actual residential condition (1.0 ACH and $24^{\circ}C$) appears to be nearly the same as that for a typical design standard (1.5 ACH and $20^{\circ}C$). The air change rate affects heating energy as sensitive]y as the set temperature. For all the simulated cases, the scheduled multi-zone heating mode is more energy-efficient than the continuous single-zone. Heating energy depends appreciably on the shading factor. It is expected that considerable heating energy for apartment houses can be saved by employing a multi-zone mode along with appropriate control devices.