• 제목/요약/키워드: urban ventilation

검색결과 156건 처리시간 0.023초

자연환기시스템의 현장 적용성 평가-열환경,에너지부분 (The Performance Field-Application of Natural Ventilation System)

  • 최동혁;최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.689-694
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high isulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, open module type natural ventilation window system for energy saving included a fixed and continuous quantity ventilation was developed. The purpose that indoor thermal comfort environment evaluate of indoor resident.

  • PDF

주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석 (An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type)

  • 최경석;정영선;강재식;이승언;정영용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

소형 공동주택의 하이브리드 환기시스템 성능실험 연구 (A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses)

  • 전주영;김길태;이종성;김상희
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

공동주택에 건강개념인 통기시스템에 관한 연구 - 공기순환과 필로티를 중심으로 - (A Study on the Air Ventilation System in Apartment Houses as a Health Concept - focused on the air ventilation and pilotis -)

  • 조철희;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제10권1호
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to analyze the air ventilation system in apartment houses focused on the air circulation and pilotis. The air ventilation system is used with the data which were obtained by the environmental health, urban climate, air pollution, ventilation path. The architectural element was pilotis concept connected with piloti ratio, piloti position and piloti type. The summaries of this study were as follows; 1) the well-being apartment concept, 2) the heat island phenomenon, 3) the oxygen density of air, 4) the definition of ventilation path, 5) the pilotis connected with residential environment improvement. In addition, the detailded case study to the air ventilation system in apartment houses be needed.

  • PDF

TDR을 이용한 중앙집중형 하이브리드 환기시스템의 결로방지 성능 평가 (Evaluation of Condensation Prevention for Centralized Hybrid Ventilation System Using TDR)

  • 김유민;이종은;최경석;이용준;강재식
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose: Condensation in the apartment housing is one of the most significant defects and complaints for condensation are rapidly increasing according to the growing interest in residential environment. Korea government established a regulation for reducing condensation in the apartment housing and TDR is adapted as a standard. However prevention of condensation depend on improving the performance of building envelop has limitation because of the increase of the cost. Centralized Hybrid ventilation system is suggested to prevent condensation. Method: Field measurement was conducted to verify the ventilation rate of the ventilation system. Based on the measurement, air network and CFD simulation was conducted to analyze ventilation rate for each room. Surface temperature was calculated by regulated TDR according to the regions and surfaces. The performance of condensation prevention was evaluated by the ventilation rate and surface temperature. Result: In the results, it was found that condensation was prevented in more than 90% of households by the centralized hybrid ventilation system which provided 0.19 ~ 0.81ACH for each room.

대구지역의 국지적 대기순환풍의 환기경로에 관한 수치모의 실험 (Numerical Simulation Experiment on the Wind Ventilation Lane of the Local Circulation Winds in Daegu)

  • 구현숙;김해동;강성대
    • 한국환경과학회지
    • /
    • 제13권4호
    • /
    • pp.367-376
    • /
    • 2004
  • In urban area, thermal pollution associated with heat island phenomena is generally regarded to make urban life uncomfortable. To overcome this urban thermal pollution problem, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane, is widely practiced in many countries. In this study, the prevailing wind ventilation lane of a local winds in Daegu during the warm climate season was investigated by using surface wind data and RAMS(Reasonal Atmospheric Model System) simulation. The domain of interest is the vicinity of Daegu metropolitan city(about 900 $km^{2})$ and its horizontal scale is about 30km. The simulations were conducted under the synoptic condition of late spring with the weak gradient wind and mostly clear sky. From the numerical simulations, the following two major conclusions were obtained: (1)The major wind passages of the local circulation wind generated by radiative cooling over the mountains(Mt. Palgong and Mt. Ap) are found. The winds blow down along the valley axis over the eastern part of the Daegu area as a gravity flow during nighttime. (2)After that time, the winds blow toward the western part of Daegu through the city center. As the result, the higher temperature region appears over the western part of Daegu metropolitan area.

The Verandah: Hong Kong's Contribution to a Southeast Asian and China-coast Urban Design

  • Faure, David
    • Journal of East-Asian Urban History
    • /
    • 제3권1호
    • /
    • pp.139-160
    • /
    • 2021
  • The verandah was a common feature of Chinese multi-storeyed houses in Southeast Asia and China. This paper argues that while an earlier version of a narrow walkway might have had its origin in Singapore, the building of an extension on the upper floors encroaching the airspace over the road skirting the building was an arrangement allowed by the colonial Hong Kong government in compensation to landlords for space devoted to ventilation. As the introduction of reinforced concrete allowed buildings to become taller, the more attractive it was to developers to incorporate the verandah design.

거칠기길이를 이용한 바람통로 네트워크 구축 (Building Wind Corridor Network Using Roughness Length)

  • 안승만;이규석;이채연
    • 한국조경학회지
    • /
    • 제43권3호
    • /
    • pp.101-113
    • /
    • 2015
  • 본 연구는 바람통로의 세밀도와 편이성을 향상시켜 도시 녹지계획 활용도를 높이는 것을 목적으로 한다. 이를 위해 유체역학적 거칠기 특성을 나타내는 거칠기길이($z_0$)로부터 바람통로 네트워크 추출기법을 제안하였다. 지적필지 단위로 산출된 $z_0$에 IDW, Spline, Kriging 내삽기법을 적용해 표면이 연속적인 수치거칠기길이모델(DZoM)을 생성한 후 수계망 추출 기법을 적용해 바람통로 네트워크를 산출하였다. 내삽기법 적용 결과들을 비교하여 가장 적합한 내삽 기법을 정하고 산출된 바람통로와 토지피복 및 지표온도의 공간적 관계를 분석하였다. 연구결과 DZoM 산출기법 중 Kriging 기법의 적용성이 IDW 및 Spline 기법보다 우수한 것으로 나타났다. Kriging 기법을 이용하여 선형 추출한 바람통로 네트워크(Type B)와 Landsat-7 ETM+에서 산출한 여름철과 겨울철 야간 지표온도 분포를 비교한 결과는 공간적 일치도가 높았다. 주목할 부분으로 산출된 바람통로의 흐름이 도시의 야간 열 부하들을 완화하는 것으로 보인다. 추출된 바람통로 네트워크 사상들(features)에 대한 엄밀한 평가와 개선이 수행된다면 녹지계획 실무에 효과적으로 활용될 수 있을 것이다. 이를 위해서는 (1) 거칠기길이 개선, (2) 녹지계획 목적에 맞는 바람통로의 해석 및 편집, (3) 분절된 바람통로 네트워크 연결, (4) 관련 자료의 상세한 구축 및 무결성 확보 등이 선행되어야 할 것이다. 제안된 바람통로 네트워크의 녹지계획 적용을 위해 향후 연구범위를 수도권으로 확장할 계획이다.