• Title/Summary/Keyword: urban parameter

Search Result 268, Processing Time 0.026 seconds

A Study on Indicator Bacteria for Water Quality Management of Urban Artificial Lakes (도심지역 인공호의 수질관리를 위한 지표세균에 관한 연구)

  • Chu, Duk-Sung;Kwon, Hyuk-Ku;Lee, Sang-Eun;Lee, Jang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.299-305
    • /
    • 2007
  • Distribution of fecal pollution indicator bacteria and environmental parameter were investigated of urban artificial lakes. An average concentration of temperature, pH, SS, DO, $COD_{Mn}$, T-P, T-N, Turbidity, Chl-a were $21.5^{\circ}C$, 8.07, 116.70 mg/l, 8.66 mg/l, 2.24 mg/1, 0.52 mg/l, 1.71mg/l, 80.54 NTU, and 52.12 mg/l respectively. From the results of bivariate correlation analysis, fecal contamination indicator bacteria were found to be mutually correlated. And turbidity and suspended solid were correlated. From the results of principal component analysis, four factors were extracted. And four factors of variance explained up to 81.5 percentage. Factor 1 was pollution pattern by fecal contamination, factor 2 was physical pollution pattern by pollution source, factor 3 was natural pollution by precipitation, and factor 4 was artificial pollution pattern by organism.

The geophysical survey and rock classification suitable for the design of a tunnel in urban area passing underneath the Gyeongbu Line(Railload) (경부선 직하부를 나란히 통과하는 도심지 터널에 있어서 지표물리탐사 및 암반등급 평가 사례 연구)

  • Lee Kun;Kim Eun-Duk;Sha Sang-Ho;Cha Young-Ho;Kim Tae-Young;Jung Doo-Suk;Hwang Nak-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.673-679
    • /
    • 2005
  • Urban conditions such as underground facilities and ambient noises due to cultural activity restrict the application of conventional geophysical techniques in general. We used the linear array microtremor technique which uses these noises as strong energy source. The result parameter of the survey is shear wave velocity profile which had been applied as an fundamental information for the determination of the rock support type in tunnel design. This study was the first case in Korea which utilized a surface geophysical technique yielding successful result in urban area especially under the existing rail ways. The quantitative relation between the shear wave velocity from this method and the rock mass rating(RMR) determined from the inspection of the cores recovered from the same boreholes showed high statistical relationship. These correlations were then used to relate the shear-wave velocity to RMR along the entire profile.

  • PDF

Applications of Geographic Information System and Expert System for Urban Runoff and Quality Management (도시유출 및 수질관리를 위한 지리정보체계 및 전문가시스템의 적용)

  • Lee, Beom-Hui
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.3
    • /
    • pp.253-263
    • /
    • 2001
  • It is very important to select appropriate methods of collecting, predicting, and analyzing information for the development of urban water resources and the prevention of disasters. Thus, in this study an accurate data generation method is developed using Geographic Information System (GIS) and Remote Sensing (RS). The methods of development and application of an expert system are suggested to solve more efficiently the problems of water resources and quality induced by the rapid urbanization. The time-varying data in a large region, the An-Yang cheon watershed, were reasonably obtained by the application of the GIS using ARC/INFO and RS data. The ESPE (Expert System for Parameter Estimation), an expert system is developed using the CLIPS 6.0. The simulated results showed agreement with the measured data globally. These methods are expected to efficiently simulate the runoff and water quality in the rapidly varying urban area.

  • PDF

Application of an extended Bouc-Wen model for hysteretic behavior of the RC structure with SCEBs

  • Dong, Huihui;Han, Qiang;Du, Xiuli
    • Structural Engineering and Mechanics
    • /
    • v.71 no.6
    • /
    • pp.683-697
    • /
    • 2019
  • The reinforced concrete (RC) structures usually suffer large residual displacements under strong motions. The large residual displacements may substantially reduce the anti-seismic capacity of structures during the aftershock and increase the difficulty and cost of structural repair after an earthquake. To reduce the adverse residual displacement, several self-centering energy dissipation braces (SCEBs) have been proposed to be installed to the RC structures. To investigate the seismic responses of the RC structures with SCEBs under the earthquake excitation, an extended Bouc-Wen model with degradation and self-centering effects is developed in this study. The extended model realized by MATLAB/Simulink program is able to capture the hysteretic characteristics of the RC structures with SCEBs, such as the energy dissipation and the degradation, especially the self-centering effect. The predicted hysteretic behavior of the RC structures with SCEBs based on the extended model, which used the unscented Kalman filter (UKF) for parameter identification, is compared with the experimental results. Comparison results show that the predicted hysteretic curves can be in good agreement with the experimental results. The nonlinear dynamic analyses using the extended model are then carried out to explore the seismic performance of the RC structures with SCEBs. The analysis results demonstrate that the SCEB can effectively reduce the residual displacements of the RC structures, but slightly increase the acceleration.

SECURITY FRAMEWORK FOR VANET: SURVEY AND EVALUATION

  • Felemban, Emad;Albogamind, Salem M.;Naseer, Atif;Sinky, Hassan H.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.8
    • /
    • pp.55-64
    • /
    • 2021
  • In the last few years, the massive development in wireless networks, high internet speeds and improvement in car manufacturing has shifted research focus to Vehicular Ad-HOC Networks (VANETs). Consequently, many related frameworks are explored, and it is found that security is the primary issue for VANETs. Despite that, a small number of research studies have taken into consideration the identification of performance standards and parameters. In this paper, VANET security frameworks are explored, studied and analysed which resulted in the identification of a list of performance evaluation parameters. These parameters are defined and categorized based on the nature of parameter (security or general context). These parameters are identified to be used by future researchers to evaluate their proposed VANET security frameworks. The implementation paradigms of security frameworks are also identified, which revealed that almost all research studies used simulation for implementation and testing. The simulators used in the simulation processes are also analysed. The results of this study showed that most of the surveyed studies used NS-2 simulator with a percentage of 54.4%. The type of scenario (urban, highway, rural) is also evaluated and it is found that 50% studies used highway urban scenario in simulation.

Study on mechanical behaviors of loose mortise-tenon joint with neighbouring gap

  • He, Jun-xiao;Wang, Juan;Yang, Qing-shan;Han, Miao;Deng, Yang
    • Structural Engineering and Mechanics
    • /
    • v.77 no.4
    • /
    • pp.509-521
    • /
    • 2021
  • The neighbouring gaps at the mortise-tenon joint in traditional timber structure, which leads to the complexity of the joint, are considered to impair the mechanical performance of the joint. In this paper, numerical simulation of loose joint was conducted to examine the deformation states, stress distributions, and bearing capacities, which was verified by full-scale test. On the basis of the experimental and numerical results, a simplified mechanics model with gaps has been proposed to present the bending capacity of the loose joint. Besides, the gap effects and parameter studies on the influences of tenon height, friction coefficient, elastic modulus and axial load were also investigated. As a result, the estimated relationship between moment and rotation angle of loose joint showed the agreement with the numerical results, demonstrating validity of the proposed model; The bending bearing capacity and rotational stiffness of loose joint had a certain drop with the increasing of gaps; and the tenon height may be the most important factor affecting the mechanical behaviors of the joint when it is subjected to repeated load; Research results can provide important references on the condition assessments of the existing mortise-tenon joint.

Experimental seismic behavior of RC special-shaped column to steel beam connections with steel jacket

  • Hao, Jiashu;Ren, Qingying;Li, Xingqian;Zhang, Xizhi;Ding, Yongjun;Zhang, Shaohua
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.101-118
    • /
    • 2022
  • The seismic performance of the reinforced concrete (RC) special-shaped column to steel beam connections with steel jacket used in the RC column to steel beam fabricated frame structures was investigated in this study. The three full-scale specimens were subjected to cyclic loading. The failure mode, ultimate bearing capacity, shear strength capacity, stiffness degradation, energy dissipation capacity, and strain distribution of the specimens were studied by varying the steel jacket thickness parameters. Test results indicate that the RC special-shaped column to steel beam connection with steel jacket is reliable and has excellent seismic performance. The hysteresis curve is full and has excellent energy dissipation capacity. The thickness of the steel jacket is an important parameter affecting the seismic performance of the proposed connections, and the shear strength capacity, ductility, and initial stiffness of the specimens improve with the increase in the thickness of the steel jacket. The calculation formula for the shear strength capacity of RC special-shaped column to steel beam connections with steel jacket is proposed on the basis of the experimental results and numerical simulation analysis. The theoretical values of the formula are in good agreement with the experimental values.

An improved multiple-vertical-line-element model for RC shear walls using ANN

  • Xiaolei Han;Lei Zhang;Yankun Qiu;Jing Ji
    • Earthquakes and Structures
    • /
    • v.25 no.5
    • /
    • pp.385-398
    • /
    • 2023
  • The parameters of the multiple-vertical-line-element model (MVLEM) of reinforced concrete (RC) shear walls are often empirically determined, which causes large simulation errors. To improve the simulation accuracy of the MVLEM for RC shear walls, this paper proposed a novel method to determine the MVLEM parameters using the artificial neural network (ANN). First, a comprehensive database containing 193 shear wall specimens with complete parameter information was established. And the shear walls were simulated using the classic MVLEM. The average simulation errors of the lateral force and drift of the peak and ultimate points on the skeleton curves were approximately 18%. Second, the MVLEM parameters were manually optimized to minimize the simulation error and the optimal MVLEM parameters were used as the label data of the training of the ANN. Then, the trained ANN was used to generate the MVLEM parameters of the collected shear walls. The results show that the simulation error of the predicted MVLEM was reduced to less than 13% from the original 18%. Particularly, the responses generated by the predicted MVLEM are more identical to the experimental results for the testing set, which contains both flexure-control and shear-control shear wall specimens. It indicates that establishing MVLEM for RC shear walls using ANN is feasible and promising, and that the predicted MVLEM substantially improves the simulation accuracy.

Parameter Estimation and Analysis of Extreme Highest Tide Level in Marginal Seas around Korea (한국 연안 최극 고조위의 매개변수 추정 및 분석)

  • Jeong, Shin-Taek;Kim, Jeong-Dae;Ko, Dong-Hui;Yoon, Gil-Lim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.482-490
    • /
    • 2008
  • For a coastal or harbor structure design, one of the most important environmental factors is the appropriate extreme highest tide level condition. Especially, the information of extreme highest tide level distribution is essential for reliability design. In this paper, 23 set of extreme highest tide level data obtained from National Oceanographic Research Institute(NORI) were analyzed for extreme highest tide levels. The probability distributions considered in this research were Generalized Extreme Value(GEV), Gumbel, and Weibull distribution. For each of these distributions, three parameter estimation methods, i.e. the method of moments, maximum likelihood and probability weighted moments, were applied. Chi-square and Kolmogorov-Smirnov goodness-offit tests were performed, and the assumed distribution was accepted at the confidence level 95%. Gumbel distribution which best fits to the 22 tidal station was selected as the most probable parent distribution, and optimally estimated parameters and extreme highest tide level with various return periods were presented. The extreme values of Incheon, Cheju, Yeosu, Pusan, and Mukho, which estimated by Shim et al.(1992) are lower than that of this result.

Impervious Surface as a Thematic Parameter of Analysis for Childhood Asthma Hospitalizations : Spatio-temporal Approaches (소아천식 유병율 분포의 분석변수로서 불투수면 : 시공간적 접근)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.6
    • /
    • pp.706-723
    • /
    • 2010
  • The impervious surface was frequently employed as a proxy of the total environmental burden in the urban area. The impervious surface was extracted from a satellite image and the GIS (Geographical Information System) database for childhood asthma hospitalizations was generated for a total of 62,136 children using the National Health Insurance database of South Korea. Children living in an impervious environment do result in almost twice as many hospitalizations (26.58%) for asthma, as compared to the sub-urban pervious living (15.82%). Furthermore, the risk zones with persistently high hospitalizations for three years were specifically identified over the impervious sub-district alone. The impervious zone showed a small inter-year variation of hospitalizations (r: 0.937) while the sub-urban pervious fringe was found to display a yearly variation(r: 0.371). The strong temporal autocorrelation means that the impervious areas have frequent long-lived hospitalizations for asthma, thus children living in impervious areas were likely to have had more chronic asthma attacks than those living in pervious areas. These experimental results indicate that an impervious surface as thematic parameter of analysis is a crucial explanatory variable for asthma hospitalizations and its longer persistence among children.

  • PDF