Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Quantitation of Hepatic and Extrahepatic $^{99m}Tc-Tin$ Colloid Uptake in the Hepatocellular Diseases (간세포성 질환에서의 간 및 간외 $^{99m}Tc-Tin$ Colloid 섭취의 정량분석)

  • Park, Young-Ha;Kim, Choon-Yul;Kim, Sung-Hoon;Park, Seog-Hee;Park, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 1987
  • It is well-known that hepatic scintigraphv have been found to be less sensitive and specific in the detection of the diffuse hepatocellular diseases than that of the space-occupying lesions. To obtain the higher diagnostic specificity and sensitivity, we, using the computer quantitation, have attempted to analyze hepatic and extrahepatic $^{99m}Tc-tin$ colloid uptake patterns in various diffuse hepatocellular diseases retrospectively. The studied groups consisted of 116 cases of normal, 67 cases of acute hepatitis, 112 cases of chronic hepatitis, 61 cases of liver cirrhosis, 47 cases of fatty liver, 12 cases of hepatoma and 9 cases of metastasis, making total 424 cases. Scintigraphic imagings were obtained in the anterior, right lateral and posterior projections using high-resolution collimation, and simultaneously these gamma data were acquisited into the computer system. Both large region of interest (ROI) using light pen and ROI computer program were placed over right lobe, left lobe of liver, spleen and cardiac blood pool. Total counts in ROI were divided by the number of pixels in the ROI, and mean count rate per pixels calculated. Mean right-lobe counts were divded by mean-left lobe counts to determine right-to-left hepatic lobe ratio and mean spleen counts were divided by mean liver counts to determine spleen to liver ratio. The results were as follows. 1) Of 424 cases, 292 were male and 132 were female. The majority of age distribution was in $30\sim49$ (54.5%). 2) Inter-observer between two independant operators and inter-method between drawing by light-pen and ROI computer program variations were not significant. 3) The uptake count values (per pixel) determined at each area in normal group were $106.53{\pm}18.35$ in right lobe, $79.00{\pm}13.82$ in left lobe, $17.52{\pm}8.31$ in spleen and $8.09{\pm}3.43$ in cardiac blood pool. 4) In liver cirrhosis, right lobe uptake was decreased but spleen and cardiac blood pool uptakes were increased (p<0.01). 5) Right-to-left hepatic lobe uptake ratio was $1.37{\pm}0.24$ in normal group and significantly low in chronic hepatitis, liver cirrhosis and fatty liver, and more or less low in acute hepatitis. 6) Spleen-to-right hepatic lobe uptake ratio was $0.17{\pm}0.09$ in normal group and high in chronic hepatitis and liver cirrhosis. 7) The computer-quantitation of hepatic and extrahepatic uptake patterns thought to be sensitive and useful method in the interpretation of liver scintigram.

  • PDF

Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans (갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구)

  • Jung-Soo Kim;Geun-Woo Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

Evaluation of Renal Uptake Rate in 99mTc-DMSA Scan on Pediatrics (소아 99mTc-DMSA 검사에서 신장 섭취율의 평가)

  • Baek, Seungju;Lee, Hyoyeong;Gil, Sanghyeong;Jo, Kyoungnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.235-238
    • /
    • 2015
  • The aims of this study were to evaluate the difference of renal uptake rate in $^{99m}Tc-DMSA$ scan on pediatrics by including the bladder. Phantom and Clinical studies were performed. In the phantom study, we put $^{99m}TcO_4{^-}$ (300uCi, 11 MBq) in 3cups filled with distilled water at the rate 1:1:0, 1:1:0.5, 1:1:1, 1:1:2 and were placed Lt kidney, Rt kidney and bladder position on the table. To acquire the image, we used Symbia-E gamma camera from Siemens with preset count method(400,000 counts). In quantitative analysis, the counts of drawing ROIs on the phantom were analyzed. In clinical studies, we analyzed the 20 pediatrics who were examined by $^{99m}Tc-DMSA$ scan. At first, the images were acquired with both kidney and bladder. Secondly we acquired images after shielding the bladder. And the data were compared using a pared t-test by SPSS(ver.22.0). As a result of renal phantom's experiment, we compared with average of uptake rate(%), 1:1:0 was Lt 43.32%, Rt 45.97%, 1:1:0.5 was Lt 35.79%, Rt 36.89%, 1:1:1 was Lt 29.68%, Rt 31.45% and 1:1:2 was Lt 22.89%, Rt 24.32%. There was no correlation between the zoom and uptake rate. The results of patient were that excluded bladder was $29.83{\pm}8.81%$(Lt), $24.29{\pm}6.66%$(Rt) and included bladder was $26.65{\pm}8.03%$(Lt, $21.78{\pm}6.24%$(Rt). This is deemed statistically significant (p<0.05). Renal uptake rate was undervalued because the counts of bladder were included in the total counts.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

The analysis of difference in the relative renal function based on total counts method and average counts method (총 계수 분석법과 평균 계수 분석법에 따른 신장 기능의 차이 분석)

  • JUNG WOO-YOUNG;CHO SHEE-MAN;PARK SEUNG-YONG;SHIM DONG-OH
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose : $^{99m}Tc-DMSA$ renal scan can be used in the evaluation of relative renal function and some anatomy. The relative renal function can be assess by measurement of $^{99m}Tc-DMSA$ uptake by the individual kidney. Renal counts

  • PDF

Studies on the Effects of Injected Amount of I131 in Uptake and Release Rate by Thyroid in Guinea Pigs 1. On the Influence of Injected Amount of Redioiodine-131 in Uptake and Release Rate by Thyroid in Male Guinea Pigs (방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 기니픽 갑상선(甲狀腺)에의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響)에 관(關)한 연구(硏究) 제(第)1보(報) 방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 웅(雄)기니픽 갑상선(甲狀腺)에서의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響))

  • Chung, Yung Chai;Shim, Sang Chil;Lee, Heung Shik
    • Korean Journal of Veterinary Research
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 1966
  • In order to observe the effect of the injected radioactive iodine-$I^{131}$ on the uptake in thyroid of normal male guinea pigs and P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum, 24 matured male guinea pigs were divided in 4 groups and $35{\mu}c$, $70{\mu}c$, $140{\mu}c$ and $280{\mu}c$ per kg of body weight respectively were injected subcutaneously. 1. The uptake rates of radioactveiodine-$I^{131}$ by external counts of thyroidal uptake reached the maximum level of uptake in 24 hours after injection. 2. As the injected amount increases, the uptake rates of maximum levels and release rate were increased. 3. Uptake rate in the removed thyroid have shown no statistical in the $35{\mu}c$ and $70{\mu}c$ groups of injected guinea pigs. 4. There was no statistical significance in $140{\mu}c$ and $280{\mu}c$ groups of injected guinea pigs. 5. P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum was not in proportion to injected amounts: 61.0%(35), 70.2%(70), 75.3%(140) and 64.8%(280).

  • PDF

Potential Utility of FDG PET-CT as a Non-invasive Tool for Monitoring Local Immune Responses

  • Lee, Seungho;Choi, Seohee;Kim, Sang Yong;Yun, Mi Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.17 no.4
    • /
    • pp.384-393
    • /
    • 2017
  • Purpose: The tumor microenvironment is known to be associated with the metabolic activity of cancer cells and local immune reactions. We hypothesized that glucose metabolism measured by 2-deoxy-2-($^{18}F$)fluoro-D-glucose ($^{18}F-FDG$) positron emission tomography (PET)-computed tomography (CT) ($^{18}F-FDG$ PET-CT) would be associated with local immune responses evaluated according to the presence of tumor infiltrating lymphocytes (TILs). Materials and Methods: We retrospectively reviewed 56 patients who underwent $^{18}F-FDG$ PET-CT prior to gastrectomy. In resected tumor specimens, TIL subsets, including cluster of differentiation (CD) 3, CD4, CD8, Forkhead box P3 (Foxp3), and granzyme B, were subjected to immunohistochemical analysis. The prognostic nutritional index (PNI) was calculated as: ($10{\times}serum$ albumin value)+($0.005{\times}peripheral$ lymphocyte counts). Additionally, the maximum standard uptake value ($SUV_{max}$) was calculated to evaluate the metabolic activity of cancer cells. Results: The $SUV_{max}$ was positively correlated with larger tumor size (R=0.293; P=0.029) and negatively correlated with PNI (R=-0.407; P=0.002). A higher $SUV_{max}$ showed a marginal association with higher CD3 (+) T lymphocyte counts (R=0.227; P=0.092) and a significant association with higher Foxp3 (+) T lymphocyte counts (R=0.431; P=0.009). No other clinicopathological characteristics were associated with $SUV_{max}$ or TILs. Survival analysis, however, indicated that neither $SUV_{max}$ nor Foxp3 held prognostic significance. Conclusions: FDG uptake on PET-CT could be associated with TILs, especially regulatory T cells, in gastric cancer. This finding may suggest that PET-CT could be of use as a non-invasive tool for monitoring the tumor microenvironment in patients with gastric cancer.

Use of $^{99m}TcO_4^-$ Salivary-Thyroid Ratio As a Test of Thyroid Function (갑상선스캔상에서 갑상선섭취율의 추정방법 : 타액선-갑상선계수율)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Chun, Ki-Sung;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.151-154
    • /
    • 1987
  • Total 114 patients were studied prospectively with radioiodine uptake (RAIU) and $^{99m}TcO_4^-$ thyroid scan to design a very simple, rapid and inexpensive method measuring the thyroid uptake on thyroid scan. After the RAIU was obtained at 24 hours after P.O. of $^{131}I$, Thyroid scan was performed at 20 minutes after LV. of $^{99m}TcO_4^-$ and the bilateral salivary glands were included in the scan field. Pinhole collimated and computer assisted gamma camera was used. Three regions of interest were set on each salivary gland and on the thyroid by automatic edge detection method. Mean counts per pixel were calculated for each ROI and the salivary-thyroid ratio (STR) was defined as; $$STR(%)=\frac{Mean\;counts\;per\;pixel\;of\;salivary\;glands\;(KC)}{Mean\;counts\;per\;pixel\;of\;thyroid\;gland\;(KC)}\times100$$ 114 cases consisted of 41 normal, 55 hyperthyroid and 18 hypothyroid patients and correlation between the STR and the RAID were evaluated in total and each group. The STR and the RAID showed reverse linear regression in 114 cases (r= -0.8, P=0) and closer correlation was shown in hyperthyroid group (r= -0_9, p=0). Mean STR in normal group was 47.6%. In predicting the RAID by STR, sensitivity and specificity were 88.3% and 64.9% in 114 cases and 95.3% and 83.3% in hyperthyroid group. It is recommended that the STR be used in place of the RAID giving same information at saving time, money and radiation exposure.

  • PDF