• Title/Summary/Keyword: up-and-down motion

Search Result 194, Processing Time 0.033 seconds

The Research of Vibration Power Generation with Two Degree of Freedom Using Ocean Wave (파도를 이용한 2자유도 파력진동발전시스템에 대한 연구)

  • Han, Ki-Bong;Lee, Hyoung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1028-1034
    • /
    • 2011
  • This paper have been studied that ocean wave power vibration generation system with two D.O.F.(degree of freedom) consists of buoy and vibration generation system with two D.O.F. for using efficiency of ocean wave energy. It selected main frequencies ${\omega}_1$, ${\omega}_2$ in frequency with ocean wave and it fitted them to the natural frequencies of vibration system with two D.O.F. in the vibrational power generation system. Then each the relative velocity of between the winding coil and the permanent magnet is faster than the velocity of ocean wave up and down motion by resonance phenomenon. Also the ocean wave power generation with two D.O.F. obtained the more electric energy then the ocean wave power generation with one D.O.F. by coupling effect for two D.O.F. vibration system. Therefore ocean wave power vibration generation system with two degree of freedom that is proposed in this paper has merits which not only using more energy in the ocean wave but also obtaining more electronic energy.

Isolated Anterior Dislocation of the Radial Head in Adult - A Case Report - (성인에서 발생된 요골 두 급성 전방 탈구 - 증례 보고 -)

  • Heo, Youn-Moo;Kim, Woo-Sik;Kim, Sung-Hun;Jeon, Teak-Soo;Kim, Sang-Bum;Oh, Byung-Hak
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.131-135
    • /
    • 2007
  • We report an isolated anterior dislocation of the radial head in a 23-year-old man after a fall on the outstretched arm. At the time of the injury, the patient's elbow was in a position of mild flexion and pronation which was suddenly further pronated as he fell down. The radial head was incarcerated by the lateral portion of brachialis muscle, and annular ligament was interposed between capitellum and radial head. Open reduction was performed. During 12 months follow-up, reduction of radial head was well maintained without a limitation of range of motion.

Comparison of retention characteristics of ferroelectric capacitors with $Pb(Zr, Ti)O_3$ films deposited by various methods for high-density non-volatile memory.

  • Sangmin Shin;Mirko Hofmann;Lee, Yong-Kyun;Koo, June-Mo;Cho, Choong-Rae;Lee, June-Key;Park, Youngsoo;Lee, Kyu-Mann;Song, Yoon-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.3
    • /
    • pp.132-138
    • /
    • 2003
  • We investigated the polarization retention characteristics of ferroelectric capacitors with $Pb(Zr,Ti)O_3$ (PZT) thin films which were fabricated by different deposition methods. In thermally-accelerated retention tests, PZT films which were prepared by a chemical solution deposition (CSD) method showed rapid decay of retained polarization charges as the thickness of the films decreased down to 100 nm, while the films which were grown by metal organic chemical vapor deposition (MOCVD) retained relatively large non-volatile charges at the corresponding thickness. We concluded that in the CSD-grown films, the thicker interfacial passive layer compared with the MOCVD-grown films had an unfavorable effect on retention behavior. We observed the existence of such interfacial layers by extrapolation of the total capacitance with thickness of the films and the capacitance of these layers was larger in MOCVD-grown films than in CSD-grown films. Due to incomplete compensation of surface polarization charges by the free charges in the metal electrodes, the interfacial field activated the space charges inside the interfacial layers and deposited them at the boundary between the ferroelectric layer and the interfacial layer. Such space charges built up an internal field inside the films, which interfered with domain wall motion, so that retention property at last became degraded. We observed less imprint which was a result of less internal field in MOCVD-grown films while large imprint was observed in CSD-grown films.

A Heave Compensation System for Offshore Crane (해상 크레인의 상하동요 보상 시스템의 능동제어)

  • Seong, Hyung-seok;Choi, Hyeong-sik;Jeong, Seong-hoon;Lee, Sang-ki
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.3
    • /
    • pp.175-181
    • /
    • 2016
  • This paper introduces a heave compensation system for offshore crane when it gets unexpected disturbances and external force. The dynamic model consists of crane assumed to be the rigid body, hydraulic driven winch, elastic rope and payload. To keep the payload from moving up and down, PD control algorithm is applied. By using the control, the oscillating amplitude of the payload is reduced. Also by using the estimated values involved with time-delay, the relative motion of payload in heave direction is dramatically shortened. This paper shows using the control algorithm with estimated value having time-delay 0.1 second is enough to heave compensation system.

Spectral Analysis of Nonliner Dynamic Response for Dynamic Instability of Shallow Elliptic Paraboloidal Shells (얕은 타원포물곡면쉘의 동적 불안정 현상의 규명을 위한 비선형 동적 응답의 스펙트럼 분석)

  • 김승덕
    • Computational Structural Engineering
    • /
    • v.8 no.2
    • /
    • pp.153-161
    • /
    • 1995
  • The dynamic instability for snapping phenomena has been studied by many researchers. There is few paper which deal with the dynamic buckling under the load with periodic characteristics, and the behavior under periodic excitation is expected the different behavior against step excitation. In this study, the dynamic direct snapping of shallow elliptic paraboloidal shells is investigated under not only step excitation but also sinusoidal and seismic excitations, applied in the up-and-down direction. The dynamic nonlinear responses are obtained by the numerical integration of the geometrically nonlinear equations of motion, and examined by the Fourier spectral analysis in order to get the frequency-dependent characteristics of the dynamic instability for various load levels. The results show that the dynamic instability phenomenon carried out from stable to unstable region reveals considerably different mechanism depending on the characteristics of excitations.

  • PDF

Evaluation of an insect-mimicking flapping device actuated by a piezoceramic actuator (곤충 비행원리를 모사한 압전 작동기 구동형 날갯짓 기구의)

  • 박훈철;변도영;구남서;모하메드 샤이푸딘
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.55-62
    • /
    • 2006
  • This paper presents experimental evaluation of an insect-mimicking flapping-wing device actuated by a unimorph piezoceramic actuator. Length of each rod and hinge point in the linkage/amplification system are carefully chosen such that the resulting wing motion can mimic clapping of wings in a real insect at the end of upstroke. In addition to this, a pair of corrugated wings are fabricated mimicking zig-zag cross section of a real insect wing. Thanks to the two additional implementation, the improved flapping wing device can generate a larger lift force than the previous model even though area of the new wing is about 50% less than that of the previous wing. In this work, effects of the wing clapping, the wing corrugation, and the input wave form on the lift force generation have been also experimentally investigated. Finally, the vortex generated by the flapping device has been captured by a high speed camera, showing that vortices are produced during up- and down-strokes.

Implementation of Marine Optical Sensor System Using A Line-CCD (Line-CCD를 이용한 수중광학 센서 시스템의 구현)

  • Jeong, Ui-Seok;Lee, Dong-Ho;Lee, Kyoung-Woon;Lim, A-Ram;Jeong, Jae-Wook;Park, Jung-Ho
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.244-249
    • /
    • 2010
  • We fabricated optical sensor system that take a measurement particles using a line-CCD in ocean. To measure particles, we used 680nm laser diode which is appropriate. we tested to operate optical system in water tank and ocean. It has performance that detected signal of sensors transfer microprocessor, FPGA as long as move up and down it's motion. The system algorithm also analysis output -pressure, temperature, particle numbers in depth.-For experiment, our particle sensor system has high accuracy counter. therefore, we proposed that a line-CCD is available on optical sensor system in ocean.

Hemiarthroplasty for the Comminuted Fracture of the Proximal Humerus (상완골 근위부 분쇄 골절에서의 상완골 두 치환술)

  • Seo Joong-Bae;Won Choong-Hee;Kim Yong-Min;Choi Eui-Seong;Lee Ho-Seung;Hong Yoon-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.61-67
    • /
    • 2000
  • Purpose: Most proximal humeral fractures are minimally displaced and can be treated satisfactorily with a conservative method. But in many comminuted fractures, hemiarthroplasty is usually done as a primary treatment. The authors evaluated how much functional improvement was achieved after hemiarthroplasty and which factors influence on the final functional results. Materials and Methods: Eleven hemiarthroplasties were performed for three- and four-part fractures(including fracture-dislocation) between April 1992 and June 1999. There were eight women and three men, and the mean age was 65 years. According to Neer classification, six was three-part fracture and five was four-part fracture. Six patients were injured on their right shoulder and five on the left shoulder. Among the five four-part fractures, three had axillary nerve injury and among the six three-part fractures, only one patient had axillary nerve injury. The average follow-up period was 2.4 years(1 year-7 years) after operation. The functional results were evaluated with the UCLA scoring system(Modification for hemiarthroplasty). In addition to the overall results, we compared the results according to the classification of the fracture, the cause of injury, and whether the axillary nerve was injured. Results: At the last follow-up, average total UCLA score was 18.2. The mean score for pain was 7.0, mean muscle power and motion score was 5.5 and 5.7 respectively. The pain relief was more satisfactory than any other functional results. The average score for three-part fractures was 22, and the average for four-part fractures was 13.6. The average score for the patients fractured by vehicle accidents was 15.3, and 19.3 for the patients fractured by slip-down injury. In patients without axillary nerve injury, the average score was 20, and with axillary nerve injury, the score was 15. Conclusion: Shoulder hemiarthroplasty, for the treatment of proximal humeral fractures, cannot restore the shoulder function to normal, but can achieve the functional result to some degree, especially for the activity of daily living. And as for pain, we think that it is relatively effective measure. And we think that the severer the comminution, the more the chance of axillary nerve injury, and the poorer the functional results. In conclusion, the severity of initial injury seems to be the major prognostic factor.

  • PDF

4-way Search Window for Improving The Memory Bandwidth of High-performance 2D PE Architecture in H.264 Motion Estimation (H.264 움직임추정에서 고속 2D PE 아키텍처의 메모리대역폭 개선을 위한 4-방향 검색윈도우)

  • Ko, Byung-Soo;Kong, Jin-Hyeung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.6-15
    • /
    • 2009
  • In this paper, a new 4-way search window is designed for the high-performance 2D PE architecture in H.264 Motion Estimation(ME) to improve the memory bandwidth. While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new window utilizes the overlapped data of adjacent search windows as well as adjacent multiple scanning (window) paths to enhance the reusage of retrieved search window data. In order to scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows, bidirectional row and column window scanning results in the 4-way(up. down, left, right) search window. The proposed 4-way search window could improve the reuse of overlapped window data to reduce the redundancy access factor by 3.1, though the 1/3-way search window redundantly requires $7.7{\sim}11$ times of data retrieval. Thus, the new 4-way search window scheme enhances the memory bandwidth by $70{\sim}58%$ compared with 1/3-way search window. The 2D PE architecture in H.264 ME for 4-way search window consists of $16{\times}16$ pe array. computing the absolute difference between current and reference frames, and $5{\times}16$ reusage array, storing the overlapped data of adjacent search windows and multiple scanning paths. The reference data could be loaded upward and downward into the new 2D PE depending on scanning direction, and the reusage array is combined with the pe array rotating left as well as right to utilize the overlapped data of adjacent multiple scan paths. In experiments, the new implementation of 4-way search window on Magnachip 0.18um could deal with the HD($1280{\times}720$) video of 1 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 149.25MHz.

The Study of HR and Energy Expenditure Change according to Walking Types (걷기유형에 따른 심박수 및 에너지소비량 변화에 관한 연구)

  • Lee, hyung-kook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.405-409
    • /
    • 2009
  • There are many types of walking exercise. We have choice the way according to the walking exercise purpose. Nordic walking(NW) is one of walking types with nordic poles. Also, power walking(PW) has motion of large swing the arm in walking, and dumbbell walking(DW) way is walking with 3-pound dumbbell. This study compared the physiological response(heart rate, energy expenditure) of general walking(GW) to another types(nordic, power, and 3-pound hand weights walking way). Seven apparently male health volunteers between the ages 19 and 24 years participated. Each complete a treadmill test. The tests were assigned randomly, as submaximal walking trials on separate days. Each walking trial was conducted on a level treadmill, for 40 minutes(3-5mile/hour 5min warm-up, 6mile/hour speed for 15min walking and 7mile/hour speed for 15min Jogging exercise, and 5-3mile/hour cool down 5min), at an same pace. Heart rate in beats per minute(bpm), and energy expenditure in kcal per minute(kcal/min) were recorded each minute. Results between trials were compared using repeated measures analysis of variance and Tukey's post hoc tests. In slow walking, it was found that walking with 3-pound hand weight way resulted in and average of ($127.8{\pm}8.27bpm$) the highest score HR, Caloric expenditure($85.4{\pm}14.51kcal/min$), responses compared to regular walking way($117.4{\pm}7.27bpm$ and $70.4{\pm}10.99kcal/min$). Nordic walking way($121.4{\pm}11.74bpm$, and $77.0{\pm}16.83kcal/min$) is second, power walking way($118.5{\pm}9.98bpm$, and $68.7{\pm}20.62kcal/min$) is next. In fast walking, it was found that walking way with 3-pound hand weight resulted in and average of ($160.1{\pm}8.72bpm$) the highest score HR, caloric expenditure($126.1{\pm}13.86kcal/min$), responses compared to regular walking way($148.4{\pm}11.94bpm$, and $109.0{\pm}4.70kcal/min$). Nordic walking way($156.7{\pm}10.82bpm$, and $113.5{\pm}14.51kcal/min$) is second, power walking way($149.7{\pm}12.56bpm$, and $109.2{\pm}17.64kcal/min$) is next. Thus, it is the unavoidable conclusion that, comparing with general walking, 3-pound hand weight walking, nordic walking, and power walking methods have the advantage of high exercise intensity and energy expenditure to meet the purpose of performers without the problem. Furthermore, 3-pound hand weight walking ways were proved to be a useful aerobic exercise method as whole body that achieves high-energy efficiency. To this extent, 3-pound hand weight walking ways can be recommended as a continuous and regulative aerobic exercise for some people.

  • PDF