• Title/Summary/Keyword: unit volume

Search Result 1,258, Processing Time 0.034 seconds

LANDFILL STABILIZATION WITH LANDFILL MINING AND THERMAL TREATMENT PROCESS

  • Gust, Micheal A.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.12a
    • /
    • pp.97-101
    • /
    • 1996
  • Municipal and sanitary landfills can pose environmental problems due to leachate, landfill gas md unstable geotechnical properties. Most governmental bodies delay the correction of landfill problems or landfill replacement until a crises stage is reached. The replacement of a landfill is often made difficult due to costly regulatory controls, public opposition to siting and the high cost of closure for the previous landfill unit. Solutions to extending landfill life and capacity Involve waste minimization by recycling, refuse compaction and waste-to-energy incineration. Incineration can reduce the volume of refuse by 50-95%. The largest installed bases of municipal waste Incinerators are located in Japan and the U.S. The volume of waste contained in a landfill can be estimated by load count tabulations, weight-and-volume measurements or a material balance analysis based on the trash profile of user categories. for an existing landfill, core samples may be collected and analyzed for use in a material balance analysis. Newly generated refuse contains approximately 50% of the heating value of coal. However, landfill properties vary significantly due to the waste profile of the contributors and biodegradation due to time and weathering. The volume of the Nanji-do landfill

  • PDF

Behavior of 2-D Biaxial braided hollow composite under bending (굽힘 하중 하에서의 2-D Biaxial Braided 중공형 복합재료의 거동)

  • 서거원;임동진;윤희석
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.12-16
    • /
    • 2000
  • This study is about the effect of braiding on the 2-D biaxial braided hollow composite(BD) compared with unidirectional hollow composite(UD). The specimens were made of T700S Carbon/Epoxy prepreg and T700S dried Carbon yarns. Fiber volume fraction of UD and BD was obtained experimentally and analytically. Fiber volume fraction of BD was derived based on unit cell of braiding yarn section. Bending test was executed to investigate the effect of braiding part. The result of experiment and analysis of fiber volume fraction has good agreement. Bending strength of BD is about 20% higher than that of UD.

  • PDF

Classification Methods for Fault Diagnosis of an Air Handling Unit (공조 시스템의 고장진단을 위한 분류기술 연구)

  • Lee, Won-Yong;Shin, Dong-Ryul;House, John M.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.420-422
    • /
    • 1998
  • All Fault Detection and Diagnosis(FDD) methods utilize classification techniques. The objective of this study was to demonstrate the application of classification techniques to the problem of diagnosing faults in data generated by a variable-air-volume(VAV) air-handling unit(AHU) simulation model and to describe the characteristics of the techniques considered. Artificial neural network classifier and fuzzy clustering classifier were considered for fault diagnostics.

  • PDF

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Characteristics of Foam Concrete with Application of Mineral Admixture (무기혼화재 적용에 따른 기포콘크리트의 특성)

  • Kim, Sang-Chel;Kim, Yun-Tae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.97-106
    • /
    • 2009
  • self-loading, various problems related to construction can be solved as well as the save of construction cost. Thus, this study has an aim of applying foam concrete to structural purpose by adding bottom ash as a reinforcing material like fine aggregate, in contrast to conventional non-structural usage such as soundproofing or insulating materials. In addition, it was evaluated in terms of unit volume weight, flow value, air void, water absorption and dosage of foam agent wether replacement of cement by granulated blast furnace slag or fly-ash has an effect on the material characteristics of foam concrete. As results of experiments, it can be found that the increase of fine aggregate ratio, that is to say, the increase of bottom ash results in the increase of unit volume weight, while decreasing air void and flow value. But, appropriate addition of bottom ash to foam concrete makes it easy to control a homogeneous and uniform quality in foam concrete due to less sensitive to bubbles. As the replacement ratio of mineral admixtures such as granulated blast furnace slag and fly-ash increases, as unit volume weight tends to decrease. In the meanwhile, serious effects were shown on fluidity of foam concrete when more than limit of replacement ratio was applied.

  • PDF

Numerical Simulation of the Elastic Moduli of Cement Paste As a Three Dimensional Unit Cell

  • Park, Ki-Bong
    • Architectural research
    • /
    • v.12 no.2
    • /
    • pp.93-98
    • /
    • 2010
  • This paper describes a numerical method for estimating the elastic moduli of cement paste. The cement paste is modeled as a unit cell which consists of three components: the unhydrated cement grain, the gel, and the capillary pore. In the unit cell, the volume fractions of the constituents are quantified using a single kinetic function calculating the degree of hydration. The elastic moduli of cement paste are calculated from the total displacements of constituents when a uniform pressure is applied to the gel contact area. The cement paste is assumed to be a homogenous isotropic matrix. Numerical simulations were conducted through the finite element analysis of the three-dimensional periodic unit cell. The model predictions are compared with experimental results. The predicted trends are in good agreement with experimental observations. This approach and some of the results might also be relevant for other technical applications.

The Influence of That Changes in Aggregate Material and Unit Binder Weight Have on the Material Properties of Regular Strength Concrete (골재원 및 단위결합재량 변화가 일반강도 콘크리트의 물성에 미치는 영향)

  • Park, Yong-Jun;Kim, Sang-Sub;Lee, Myeong-HO;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.17-18
    • /
    • 2015
  • In the case of concrete recently manufactured with a concrete mixing truck, although aggregate and cement are used as the main ingredients, from a costs savings perspective, low quality aggregates are processed and used as concrete aggregate. In the case of these low quality aggregates, the unit volume and unit binder weights are increased for manufacturing, and due to this problems such as dry shrinking of the architecture and economic infeasibility have arisen. Therefore by changing the aggregate material and the unit binder weights that are currently being distributed, this research analyzes the influence on concrete.

  • PDF

Extraction of similar XML data based on XML structure and processing unit

  • Park, Jong-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.59-65
    • /
    • 2017
  • XML has established itself as the format for data exchange on the internet and the volume of its instance is large scale. Therefore, to extract similar information from XML instance is one of research topics but is insufficient. In this paper, we extract similar information from various kind of XML instances according to the same goal. Also we use only the structure information of XML instance for information extraction because some of XML instance is described without its schema. In order to efficiently extract similar information, we propose a minimum unit of processing and two approaches for finding the unit. The one is a structure-based method which uses only the structure information of XML instance and another is a measure-based method which finds a unit by numerical formula. Our two approaches can be applied to any application that needs the extraction of similar information based on XML data. Also the approach can be used for HTML instance.

SMC Full PACS로의 전환 및 System 구축

  • Kim, Sam-Soo;Ro, Duk-Woo;Cheung, Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.20-23
    • /
    • 1997
  • The purpose of this paper is to describe the transition of a 1,100 beds teritary hospital from 50% softcopy operation to full PACS operation. For the past 2 years, radiologists and clinicians have been using PACS to provide softcopy services to the outpatient clinics and inpatient wards of orthopedics surgery, neurosurgery and neurology as well as emergency room, surgical intensive care unit, medical intensive unit, pediatrics intensive care unit and neonatal intensive care unit. The examinations requested by these departments account for about 50% of hospital's radiological exams. In September 1996, we began the second phase of PACS implementation and installed additional workstations (102) in the remaining wards and clinics, interfaced to PACS additional imaging modalites, and increased the capacity of both the image server (256 Gbytes) and optical juke boxes (3 Tbytes). As of January 1997, we are in the final phase of moving away from conventional film system to full PACS operation.

  • PDF

Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit (전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.