• Title/Summary/Keyword: unit pulse

Search Result 333, Processing Time 0.022 seconds

A New Driving Scheme for Reduction of Addressing time and its Dispersion in AC PDP

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Park, Cha-Soo;Park, Chung-Hoo;Ryu, Jae-Hwa
    • Journal of Information Display
    • /
    • v.2 no.2
    • /
    • pp.39-44
    • /
    • 2001
  • The conditions of the wall charges and priming particles in a unit discharge cell in AC PDP seriously affect the addressing discharge characteristics in the driving method with ramped setup pulse. Moreover, the discharge conditions at the end of the scan line may be different from the first scan line because of the difference of about 1ms address time. Consequently, the addressing time and its dispersion may be different for any two discharge cells that lead to misfiring and the increase in the total addressing time. In order to improve the addressing time and its dispersion, we have applied different addressing voltage at each cell such as progressively increase pulse voltage instead of constant one. As a result, the addressing time and its dispersion of all cells were improved by about 30% compared with the conventional driving method.

  • PDF

Development of Surgical Two-wavelegth Nd:YAG Laser (수술용 2파장 펄스형 Nd:YAG 레이저 개발)

  • 윤길원;김홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

A Study on the Design and Modeling of PWM Fuel Metering Unit for Miniature Turbo Engines (초소형 터보엔진용 PWM 연료조절장치의 설계 및 모델링에 관한 연구)

  • Joo Sang-Hyun;Choi Ho-Jin;Park Jong-Seung;Lim Jin-Shik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • A fuel metering unit using PWM(Pulse Width Modulated) solenoid valve has some advantages such as low cost, small size and simple structure. The mathematical model and its experimental rig of the fuel metering unit using PWM solenoid valve and CPDV(Constant Pressure Drop Valve) for miniature turbo engines were constructed. As the results of simulation, some major parameters which have dominant effects on the performance were found. And the experimental results verified the validity of established model by showing the good agreement with the numerical simulation results. Hence, this system modeling could be used effectively in the actual development of a PWM fuel control system.

Pain Reducing Effects of Dextrose-coated Pacifier on Venipuncture in Premature Infants (포도당 코팅 노리개 젖꼭지 제공이 미숙아의 정맥주사 시 통증 반응에 미치는 효과)

  • Seo, Jung-Suk;Kwon, In-Soo;Kim, Hee;Jung, Young-Ran;Jo, Sung-Jin;Hwang, Ju-Young;Kang, Hyun-Sun
    • Korean Parent-Child Health Journal
    • /
    • v.13 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the pain reducing effects of the dextrose-coated pacifier on venipuncture in premature infants. Methods: The design of this study is a nonequivalent control group pretest-posttest design and a crossover trial. The analysed cases were 40 premature infants (20 in experimental group and 20 in control group) in neonatal intensive care unit of a University Hospital, Gyeongnam Province, Korea. The data were collected from April to October, 2009. The experimental treatment was carried out nursing 20% dextrose-coated pacifier on venipuncture for IV injection. The instruments were $O_2$ saturation and heart rate on pulse oxymeter monitor to measure physiologic pain responses, and NIPS to measure behavioral pain responses. Collected data were analyzed with $x_2$ test, t-test using SPSS program. Results: The effects of the 20% dextrose-coated pacifier were found in the physiologic (only heart rate) and behavioral pain response on venipuncture. Conclusion: These finding is suggested that the dextrose-coated pacifier could be an effective nursing intervention for reducing pain on venipuncture in premature infants.

  • PDF

Double Pulse Raman-Laser Induced Plasma Spectroscopy System for Space Exploration (우주 탐사를 위한 이중펄스 라만-레이저 유도 플라즈마 분광 시스템 개발 연구)

  • Yang, Jun-Ho;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.479-487
    • /
    • 2020
  • A new double-pulse laser system that combines Raman and laser induced plasma spectroscopy (LIPS) in a single unit is proposed. The study attempts to enhance the laser induced plasma signals while simultaneously extracting the desired molecular signals from Raman spectroscopy. In low pressure conditions such as the lunar atmosphere, the measuring of plasma emission is hard because of the low electron density and short persistence time causing a rapid plasma expansion. Furthermore, in the integration of the detecting system aimed at space exploration, the minimization of laser system is important in terms of the payload mass. Simultaneous molecular and atomic detection that gave highly resolved spectral data at pressure below 0.07 torr is demonstrated amongst eight rock samples test. The plasma stacking produced from the double-pulse laser enhanced the signal intensity of calcium and oxygen lines in calcite matrix by twofold, compared to a conventional LIPS.

Study of PSII-treated PMMA, PHEMA, and PHPMA ; Investigation of Their Surface Stabilities

  • Hyuneui Lim;Lee, Yeonhee;Seunghee Han;Jeonghee Cho;Moojin suh;Kem, Kang-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.204-204
    • /
    • 1999
  • The plasma source ion implantation(PSII) technique which is a method using high negative voltage pulse in plasma system has the potential to change the surface properties of polymer. PSII technique increase the surface free energy by introducing polar functional groups on the surface so that it improves reactivity, hydrophilicity, adhension, biocompatability, etc. However, the mobility of polymer chains enables the modified surface layers to adapt their composition to interfacial force. This hydrophobic recovery interrupts the stability of modified surfaces to keep for the long time. In this study, poly(methyl methacrylate)(PMMA), poly(2-hydroxyethyl methacrylate)(PHEMA), and polu(2-hydroxypropyl methacylate)(PHPMA) for contact lens application, were modified to improve the wettability with PSII technique and were investigated the surface stabilities. Polymer film was prepared with solution casting(3 wt.% solution) and was annealed at 11$0^{\circ}C$ under vacuum oven to remove solvent completely and to eliminate physical ageing. The thickness of the film measured by scanning electron microscopy (SEM) and surface profilometer was about 10${\mu}{\textrm}{m}$. Polymers were treated with different kinds of gases, pulse frequency, pulse with, pulse voltage, and treatment time. Even though PMMA, PHEMA, and PHPMA have similar repeat unit structure, the optimal treatment conditions and the tendency to hydrophobic recovery were different. PHPMA, more hydrophilic polymer than PMMA and PHEMA showd better wettability and stability after mild treatment. Surface tensions were obtained by water and diiodomethane contact angle measurements to monitor the relation between hydrophobic recovery and polymer structure. Different ion species in plasma change the polar component and dispersion component of polymer surface. For better wettability surface, the increase of polar component was a dominant factor. We also characterized modified polymer surfaces using x-ray photoelectron spectroscopy(XPS), secondary ion mass spectrometry(SIMS), Fourier Transform infrared spectroscopy(FT-IR), and SEM.

  • PDF

Feature Extraction of Radar Signals Using Streaming Process (스트리밍 처리에 의한 레이더 신호 특성 추출)

  • Kim, Gwan-Tae;Ju, Young-Kwan;Jeon, Joongnam
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.31-38
    • /
    • 2020
  • Radar signal identification of electronic warfare is a technology that recognizes the pulse repetition interval (PRI) from a set of pulse description words (PDWs) generated by the signal receiver. Conventionally batch processing is widely used in which a number of PDWs are collected as a unit and identifies PRI from the batch. In this paper, we propose a feature extraction algorithm based on the streaming process. This technique does not wait to form a batch. Whenever a PDW(Pulse Description Word) is generated from the signal receiver, the streaming process tries to form a cluster of PDWs, and makes the DTOA (Difference of Time of Arrival) histogram, finds out the frame PRI based on the concentration ratio, and decides the number of stagger stages. Experiments proved that the proposed algorithm derives stable recognition results as the cluster size increases.

Investigation on the Analysis of Transmission Line with Frequency Dependent Lossy Term

  • Ichikawa, Satoshi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.650-653
    • /
    • 2002
  • The increaseing speeds are accompanied by decreases in pulse rise and fall time in VLSI circuits. These accenturate the high frequency spectral contents of the signals and cause the frequency dependent loss of the conductors which interconnect the various sub-circuits composing of VLSI circuit. The lossy effect is approximated by the square root of frequency dependence of the per unit length resistance. In the practical applications, several problems may arise along with this approximation, so we extend our investigation of the lossy effect by numerical Laplace inversion method.

  • PDF

Performance Improvement of Smart Counter for Uneven Small Grain (지능형 미소비균일체 계수기의 성능개선)

  • Cho, Si-Hyeong;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.127-131
    • /
    • 2009
  • This paper presents the development of smart counting system that is proper for grains with uneven unit weight or shape. This device can detect the small differences of a light beam and count the pulse from wave shape control, when the grain is going on the light screen, which is made by the light beam screen sensor. It can, different from the former conventional device, distinct the uneven grains for counting detect, by using the dedicated hardware and the software algorithm of the light sensor.

  • PDF

Nonlinear digital position control of brushless DC motors for direct drive robot (브러쉬없는 직류전동기의 비선형 디지탈 위치제어)

  • 홍기철;남광희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.252-257
    • /
    • 1990
  • For the position control of BL-DC motors, 2.phi.-3.phi. conversion unit, hysteresis band device, and PWM pulse generation are required. By utilizing a single-chip processor INTEL 8097BH, we cover all required functions. As a result, no analogue device is employed in this control scheme, so that it makes BL-DC motor controller simple and flexible. Furthermore, the single-chip processor is utilized for the nonlinear coordinate transformation which is necessary for the linearization of the motor system.

  • PDF