• 제목/요약/키워드: unit area

Search Result 3,811, Processing Time 0.032 seconds

A Study on the Area Composition of the Operating Unit After Remodeling (수술부 리모델링을 통한 공간구성 변화에 관한 연구)

  • Kim, Khilchae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.

Analytical Study for the Plan of Unit Household in National Housing Scale - Oriented on the cases of Korea housing corporation since 2005 ; Focused on analysing area (국민주택규모 단위세대 평면 분석 연구 - 2005년 이후 대한주택공사 사례를 면적분석 중심으로 -)

  • Lee, Jeong-Ho;Lee, Chan
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.180-189
    • /
    • 2010
  • Since collective houses are started to be supplied, the housing market has been transformed from supplier to demander oriented, and various type with same area of unit households have been deigned and started to be distributed. It can be expected that such transfer phenomenon would be continuously sped-up, and unit household will be more subdivided and varied. Thus, we analysed and studied the planes with subject of unit households in national housing scale ($85m^2$) that is treated as supply standard and has biggest volume in construction by Korean housing corporation. The analysing method is investigating the area of each room within unit household, calculating their minimum, maximum, and average values, studying the efficiency of unit household plane according to the structure of each room by comparative analysis these values, and analysing changing matter by investigating any change of each room area. The analysing results of which are followings. At first, number of BAY on face is increasing. Second, allocation of each room has been vary. Third, area ratio among bedroom1, livingroom, diningroom/kitchen become similar. Fourth, the area of diningroom/kitchen become somewhat bigger. Fifth, the space for passage way is efficiently allocated. Sixth, service area is reduced, Seventh, stereotyped phenomenon Is appeared. Based on many studies so far, any improvements of unit householder in national housing scale are followings. First, in terms of forming style, unit householder in national housing scale is unfolded in various way though, the form of each room is not more than typical style. Second, it shows stereotyped phenomenon. Especially, bathroom 1, 2 show stereotyped feature in terms of their type and area across entire research years, also LDK allocation method is stereotyped, as well as stereotyped trend in bedroom 2, 3, allocation for 4 BAY type.

A Study of the Specific Items and Contents of District Unit Plan for Responding to Commercial Gentrification - Focused On the 'District Unit Plan' of Seochon, Ikseon and Ttukseom surrounding area - (젠트리피케이션 대응을 위한 지구단위계획 항목 및 내용 분석 - 경복궁서측, 익선, 뚝섬주변지역 지구단위계획을 대상으로 -)

  • Kim, Su-young;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.10
    • /
    • pp.103-114
    • /
    • 2019
  • This study analyzed the specific items and contents of district unit plan for responding to commercial gentrification on the west side of Gyeongbokgung Palace, Ikseon and Ttukseom surrounding area. By analyzing the major regulatory items and ranges currently used in the 'district unit plan' for responding to gentrification, it was intended to draw up the limitations of the district unit plan of the study target and the significant issues to be considered when establishing a district unit plan for future respond to gentrification. In the district unit plan around Seochon, Ikseon and Ttukseom surrounding area, location restrictions are imposed on franchises for responding to gentrification in common, and in the case of Ikseon and Ttukseom surrounding area, the maximum development scale is especially smaller than that of the surrounding areas. Also, in the Ttukseom surrounding area, incentives are given to the use of certain exterior materials to preserve regional characteristics.

Unit Loads of Pollutants in a Paddy Fields Area with Large-Scaled Plots during Irrigation Seasons (관개기 대구획 광역논에서의 오염부하 원단위)

  • 오승영;김진수;김규성;김선종;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.136-147
    • /
    • 2002
  • Characteristics of unit loads of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of 1999 ∼2000. The average irrigation requirement of experimental paddy area are estimated at over 3,000 mm. The unit loads of pollutants in paddy fields area are determined by subtracting irrigation water load from outflow load (percolated and surface outflow loads). Surface outflow load in rainy days was calculated using the relationships of discharge and load, which are grouped into fertilizing and non-fertilizing periods. The ratios of the surface outflow load in rainy days to the total surface outflow load are 16.4% for T-N, 26.8% for T-P, and 23.3% far CODc,. The unit loads of pollutants show month-to-month and year-to-year variations, and monthly unit load of pollutants can show negative values, indicating that the paddy area acts as the pollutants sink. The average unit loads of the pollutants during irrigation seasons were estimated at 18.2 kg/ha fur T-N, 0.31 kg/ha for T-P, and 43.3 kg/ha for CODc,, which are smaller than the reported values for Kosei area in Japan.

Stratigraphic Sequence and Depositional Environment of Unconsolidated Deposits in the West Seacoast (서해안 미고결 지층의 퇴적이력 및 퇴적환경)

  • Lee, Yong-Mok;Choi, Eun-Kyeong;Kim, Sung-Wook;Lee, Kyu-Hwan;Yoon, Yeo-Jin;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.10
    • /
    • pp.55-68
    • /
    • 2012
  • The west seacoast has approximately 83% of tidal flat in Korea. Gyeonggi-do and Inchon has 35.1%. This study was carried out to understand depositional environment and properties of tidal deposits that distributed in the Gyeonggi bay. On the basis of observation and description on mineralogical, geochemical, physical properties, detailed sedimentary unit has been respectively distinguished Based on. stratigraphic position, facies and unconformity, the intertidal zones are classified into four sedimentary units, and bedrock over the units has been developed in the order of Unit 4${\rightarrow}$Unit 3${\rightarrow}$Unit 2${\rightarrow}$Unit 1. The intertidal sediment deposits of Gyeonggi Bay were compared with those of west coast. In Cheongra area all strata of Unit 4-Unit 3-Unit 2-Unit 1 appear. In Yeongjong-do Unit 2-Unit 1, in Incheon Bridge and Songdo area Unit 4-Unit 3-Unit 1 are observed. In Daesan area Unit 4-Unit 3-Unit 1 are observed. Average clay mineral content ratio is 8.2% in Cheongra area, 2.9% in Yeongjong Island, 18.4% in Incheon Bridge, 24.6% in Songdo area.

A Study on the Unit Block Types and Physical Characteristics of Individual Residential Area in Seoul (도시단독주택지(都市單獨住宅地) 단위(單位)블록의 유형화(類型化)와 이의 물리적(物理的) 특성(特性)에 관한 연구(硏究))

  • Jun, Byung-Kwun
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.125-136
    • /
    • 2007
  • To improve the environment of individual residential area, the uniform development of multiple dwellings through site should be avoided. As an alternative to a large scale development of the currently popular high-density and high-rise apartment buildings, which disintegrates and destroys existing communities, a new residential type that is applicable to the individual residential area should be developed. From the new residential type, even for short history of Korea of modem urban residence, a new concept of residence can be formed, changing from the concept of a temporary staying place to the concept of a stable residing place. Also, a gradual improvement that transcends time can be expected, and the present and past appearances can co-exist. This study was conducted to suggest a new residential type with unit blocks that can improve the physical structure of existing individual residential area without destroying the structure. That is, among the factors that comprise the individual residential area, this study will focus on the unit block with a medium role between a site and a mega-block, and will suggest a new concept of residential unit in order not to destroy its physical structure. The physical characteristics of the unit block will also be analyzed.

CEPHALOMETRIC STUDY OF OBSTRUCTIVE SLEEP APNEA PATIENTS IN THE UPRIGHT AND SUPINE POSITIONS

  • Kim, Jong-Chul;Lowe, Alan A
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.655-664
    • /
    • 1995
  • Sixty male patients with polysomnographically documented OSA were included in this study. A pair of cephalograms were obtained in the upright and supine positions. In the supine position, the ANB angle, lower facial height and the cross-sectional area of soft palate increased and there was a decrease in the vertical airway length and oropharynx cross-sectional area. Positional changes did not affect the cross-sectional area of tongue, but the cross-sectional area of the oropharynx decreased in the supine position. The obese group had higher AI and RDI. Maxillary unit length, C3-H, the cross-sectional areas of tongue, soft palate and oropharynx were significantly greater in the group Obese than in non-obese group. No correlation was noted between the mandibular unit length and OSA severity, The group of small mandibular unit length showed shorter lower facial height and maxillary unit length, and smaller cross-sectional area of tongue than the long mandibular unit length group. Hyold bone positioned more inferiorly and cross-sectional area of nasopharynx decreased as the OSA severity increased.

  • PDF

A Study on the Calculation of Thermal Consumption Unit of Apartment (공동주택의 열사용량원단위 산정에 관한 연구)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016 (국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로)

  • Yoon, Hyung Jin;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

The Calculation of NPS Load per Unit Area in Orchard to the Nakdong River Basin (낙동강유역 과수재배지의 단위면적당 비점오염부하량 산정에 관한 연구)

  • Lee, Jae-Woon;Kwon, Heon-Gak;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.557-568
    • /
    • 2013
  • In this study, Calculated the nonpoint sources(NPS) load per unit area about various rainy events in vineyard of Nakdong River basin. NPS monitoring and calculation for NPS load per unit area were estimated from 'Investigation method of precipitation discharge(National Institute of Environmental Research, 2007)'. The evaluation of applicability for NPS load per unit by compared with prior research data and Total Maximum Daily Load(TMDL) data. Five target areas were each $2000m^2$, $1800m^2$, $1943m^2$, $2484m^2$, $864m^2$ and located in Gyeongsangbukdo Gyeongju, Gyeongsangbukdo Sangju, Gyeongsangnamdo Hapcheon in Korea. Since fruits were the only crop on the target area, the characteristics of stormwater discharge at survey sites could be evaluated independently. A total of 115 rainfall events in the Orchard area during five years(2008-2012) was surveyed, and 38 of them became stormwater discharge. In the Nakdong River watershed, average of event mean concentrations(EMCs) in Orchard area for biochemical oxyzen demand(BOD), Chemical oxyzen demand(COD), total nitrogen(T-N), total phosphorus(T-P) were 2.0mg/L, 10.1mg/L, 3.195mg/L, 0.578mg/L, respectively. NPS load per unit area in Orchard area showed BOD : $2.0kg/km^2{\cdot}day$, COD : $10.2kg/km^2{\cdot}day$, T-N : $3.220kg/km^2{\cdot}day$, T-P : $0.606kg/km^2{\cdot}day$.